1 / 18

S5 Data Quality

S5 Data Quality. John Zweizig LIGO/Caltech LSC/Virgo DetChar Session Baton Rouge, March 21, 2007. Segment Source Classes. Category A : data that don't exist or are not taken during normal locked Science mode running Category B : transients in channels with direct coupling to LSC

uriah
Download Presentation

S5 Data Quality

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. S5 Data Quality John Zweizig LIGO/Caltech LSC/Virgo DetChar Session Baton Rouge, March 21, 2007

  2. Segment Source Classes • CategoryA: data that don't exist or are not taken during normal locked Science mode running • CategoryB: transients in channels with direct coupling to LSC • CategoryC: Noisy IFO auxillary channels • CategoryD: Noisy periods based on PEM and other data. • CategoryE: Informational and statistical.

  3. Class A • Class A subdivisions • Not read out correctly (Daq Error) • Not recorded correctly • Not from standard science mode • Calibration problems • Generally safe • Should be vetoed in all analyses

  4. Category A: No data • Daq data-valid error • INVALID_DARMERR (supersedes DAQ_ERROR) • CHECKSUM_MISMATCH • LHO raw data lost after LDAS disk failure • MISSING_RAW • Missing/corrupted h(t) data • CORRUPTED_RDS_C02_LX • MISSING_RDS_C02_LX • Missing RDS data • MISSING_RDS_LEVEL_1 • MISSING_RDS_LEVEL_3 • MISSING_RDS_LEVEL_4

  5. Category A: Not Science Mode • AS port using AS_PD5 only • AS_TRIGGER • Not science mode running • OUT_OF_LOCK • OUT_OF_SCIENCE_MODE • Invalid calibration • BAD_SENSING: Drastic changes in sensing gain. • BAD_CALIBCOEFFS_60: Calibration data not valid

  6. Class A Segment Dead Times

  7. Category B - PD Overflows • Overflows in LSC photo-diode ADCs • PD_Overflow, MASTER_OVERFLOW_LSC include overflows of signals not considered dangerous (e.g. Xn:LSC-SPOB) • Recommend using SEVERE_LSC_OVERFLOW only (V2 retroactive to start of S5). • LSC_OVERFLOW: contains segments with overflows not expected to impact analysis (see class C).

  8. Category B: Cal-line dropouts • Segment types: • CALIB_DROPOUT_1SAMPLE • CALIB_DROPOUT_1SEC • CALIB_DROPOUT_AWG_STUCK • CALIB_DROPOUT_BN • CALIB_GLITCH_ZG • Differ in size, length • Frequeny redued significantly since ~June, 2006

  9. Category B: Suspension Damping • H2 MMT3 Optical Lever: lots of glitches • MMT3_OPTICAL_LEVER • H2 ITMX, ITMY OSEM sensor glitches fed into test mass position because of inadequate damping servo filters. • OSEM_GLITCH

  10. Category B: TCS Glitching (new) • TCS Lasers skip mode occasionally causing glitches in DARM_ERR • Shantanu tabulated TCS glitches to form the TCS_GLITCH_LOUD segments

  11. Class B: Ancillary ADC Overflows • Segment types • ASC_Overflow (equiv. MASTER_OVERFLOW_ASC) • ASI_CORR_OVERFLOW • MASTER_OVERFLOW_SUS_MC2 • MASTER_OVERFLOW_SUS_RM • Potential NEW segments: • Severe ASC Overflows (WFS and TBD) • Coil Overflows?

  12. Class B Dead Times

  13. Class C Segment type • Segments derived from IFO Channels • Veto safety may be a concern • Light dips tabulated by Peter Shawhan • LIGHTDIP_XX_PERCENT • ADC overflows ancillary to LSC servo • LSC_OVERFLOW • SEISMIC_EY_99PCTL_3_10HZ

  14. Class C Segment Dead Times

  15. Class D Segment types • Generally from PEM channels (safe?) • Coupling between IFOs • H1_Not_Locked • H2_Not_Locked • Power line glitches • POWERMAINS_DISRUPTION • POWERMAINS_GLITCH • POWMAG • Seismic/wind PEMS • TRAIN_LIKELY • Wind_Over_30MPH

  16. Class D Segment Dead Times

  17. Class E Segments Information • PRE_LOCKLOSS_XX_SEC • CBC_1YR_INJ_CHALLENGE • Injection

  18. Class E Segment Dead Times

More Related