Utopia manufactures the finest Temperature & Humidity Control Chamber and Test Chamber which is helpful in maintaining the desired environment in the clean room..http://www.utopia.com.sg/airconditioning_humidity_control_chambers_test_chambers.html
E N D
Utopia produces one of the best temperature and humidity control chamber and test chamber. These chambers are typically used to ensure that the appropriate temperature and humidity are maintained in critical environments such as clean rooms.
Utopia’s temperature and humidity control chamber and test chambers are able to satisfy all these criteria, making them suitable for a wide variety of testing purposes such as material testing, function testing, thermal accelerated aging test and climate testing. These testing are suitable on composite materials such as cements and concrete, plastics materials or electronic components in various fields such as the automotive, construction, aerospace industries, and electronics industries.
Utopia also provides walk-in chambers that enable large items or batches of items to be tested under various temperature and humidity conditions. There is access on the side that can monitor the temperature and gather the test data even while the test is still ongoing. These walk-in chambers are large enough to fit full-size pallets for temperature and humidity preconditioning requirements.
Utopia provides unidirectional filtering ceiling for special strict environments such as surgical rooms. One of the unique characteristic of the unidirectional filtering ceiling provided by Utopia is that the shape is octagon instead of the traditional square or rectangle shape.
Having an octagonal ceiling has the advantage of not unnecessary protecting the angles that are redundant. This reduces the operating and maintenance costs of a unidirectional filtering ceiling due to the rational that the running cost is proportional to the required air flow which in turn, is determined by the surface area of the ceiling installed.
An octagonal design compared with a square design reduces the overall surface area of the ceiling by about 20 per cent. This reduction in surface area also brings down the required air flow to about 7200 cubic meter s per hour. The unidirectional filtering ceiling is also known as laminar ceiling. Its octagonal shape is 3.2 meters long on each side. There are a total of 8 trapezoidal absolute filters that are rated with an efficiency of H14. They are designed such that they are larger in the middle of the ceiling.
This allows higher velocity to be achieved which resulted in better elimination of contamination based on the assumption that the area in the middle is the most important where the highest level of sterile air is required. The trapezoidal filters are built with a mechanism to ensure that the air falls circularly around the filters. Re-suction fans are employed to remove any air that is not handled by the HEPA filter.
To Find Out More Information Airconditioning & Humidity Control Please Come And Visit Us Today Onwards..! Utopia Aire Pte Ltd Contact Us: 7 Kaki Bukit Place, Eunos Tech Park, Singapore 416185 Tel : (65) 6746-7577 Fax: (65) 6746-4994 Email : contact@utopia.com.sg Web : http://www.utopia.com.sg/