310 likes | 577 Views
Evaluating the Reliability of VIL Density for Determining Severe Hail in Iowa. Penny Zabel. Overview. Introduction. Data Analysis. - Estimation by VIL Density. - Baron Radar Algorithm. Results. Future. Vertically Integrated Liquid. VIL= ∑ 3.44 x 10 -6 [(z i +z i+1 )/2] 4/7 dh.
E N D
Evaluating the Reliability of VIL Density for Determining Severe Hail in Iowa Penny Zabel
Overview • Introduction • Data Analysis - Estimation by VIL Density - Baron Radar Algorithm • Results • Future
Vertically Integrated Liquid • VIL=∑ 3.44 x 10-6[(zi+zi+1)/2]4/7 dh • zi and zi+1 are reflectivity values at top and bottom of layer with depth dh. • VIL is the equivalent liquid water content value derived from radar reflectivity data. (American Meteorological Society, 2000)
Cone of Silence (American Meteorological Society, 1993)
VIL Density • VIL Density = VIL / Echo Top • Makes VIL independent of height. • Reduces distance error in radar measurements
Typical VIL and VIL Density VIL Density VIL 82 g/m^2 4.25 g/m^3
Within Cone of Silence VIL Density VIL 23 g/m^2 5.25 g/m^3
How Can VIL Density Estimate Hail Size? • Reflectivity is proportional to the diameter of a target to the sixth power. • Reflectivity increases exponentially as target size increases. • VIL increases exponentially.
Drop Size is Everything! (American Meteorological Society, 1993)
Data • 110 Hail reports • 2 events each from spring, early summer, and late summer. • Recorded VIL, echo top, and calculated VIL Density for each report.
Average VIL Density • 0.75”-0.99” 4.39 g/m3 • 1.00”-1.99” 4.61 g/m3 • 2.00”or greater 5.30 g/m3
Data Summary • A VIL density of 4.0 g/m3 correctly identified 93% of all hail reports. • This is a higher VIL density threshold than previous papers.
Data Summary • Amburn and Wolf 3.5g/m3 90% (Amburn and Wolf, 1996) • Baumgardt and King 3.5g/m3 90% (Baumgardt and King, 2002) • Troutman and Rose 3.5g/m3 81% (Troutman and Rose, 1997) • Roeseler and Wood 3.5g/m3 72% (Roseler and Wood, 1997)
Wet Bulb Zero Height • Low wet bulb zero height means more of the energy that is back-scattered can be from frozen instead of liquid targets. • A low wet bulb zero height also often signifies less instability, and smaller updrafts.
Overestimate Hail Size • Low wet bulb zero height may lead to high VIL density, but small hail. • April 8, 1999 WBZ 7,000 ft. • VIL density of 4.25 g/m3 • Hail size 0.75”
Underestimate Hail Size • High wet bulb zero height may lead to large hail with small VIL density. • July 2, 1999 WBZ 13,400 ft. • VIL density of 3.50 g/m3 • Hail size 1.75”
VIL is not the only thing • VIL Density is an indicator, but should be used in conjunction with other radar signatures of severe hail. • Three Body Scatter Spike • Bounded Weak Echo Region
BWER BREF 1
BWER BREF 2
BWER BREF 3
Results • A greater VIL density is needed for large hail in Iowa than in the south where other studies have been done. • Wet bulb zero height is one factor in this.
Results (cont.) • Distance does not significantly affect calculations based on VIL density. • When using Baron algorithm to estimate hail size, meteorologists should keep in mind differences in atmospheric conditions.
Future • Examine more data to determine any stronger correlations. • Examine the possibilities of updating the radar algorithm to include a factor for wet bulb zero height.
Thanks to:KCCI-TV*John McLaughlinGreg WilsonBaron Radar Systems