An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Use of RID IdentiFINDER ultra in Expert Mode

  2. Enter expert mode • Command “OPTIONS”

  3. Expert mode – show spectrum • Go through menu • Or directly from the identification display

  4. Expert mode – spectrum menu Function 1 Function 2 • Functions of the spectra mode EXIT CURRIGHT CLEAR LOAD SUB CHAN./ENERGY LT/RT PRESET ACQ/STOP CURLEFT ZOOM + - SAVE IDENTIFY LOG/SQRT/LIN TESTM SLIBSPEC SKIP

  5. MORE OPTIONS SHOW SPECTRUM IDENTIFY OPTIONS PRESET SETUP RECALIBRATE ADVANCED OPTIONS MORE OPTIONS GAMMA/N COUNTING FINDER OPTIONS DOSERATE OPTIONS ALARM OPTIONS ADVANCED OPTIONS SETUP DISP./TIME MAINTENANCE STABILIZATION CALIBRATION SOURCE DATA LOGGING MAINTENANCE CHANGE PASSWORD SHOW STATUS FACTORY DEFAULTS ERASE ALL SPECTRA FACTORY TESTS Expert mode – main menu

  6. Expert mode – main menu MORE OPTIONS See next page • DOSERATE OPTIONS • IntTime [s] 15 • Unit Sv/h, rem/h, Bq GAMMA / N COUNTING • ALARM OPTIONS • Alarm Indication: ON/OFF for sound, vibrating and light • Dose alarm level 200 mSv • Dose rate alarm level 100µSv/h • Neutron alarm level 2 per 20 sec. • FINDER OPTIONS • Time [0.1s] 3 • Sensitivity [%] 100

  7. Expert mode – more options DO CALIBRATION Starts re-calibrating process SHOW SPECTRUM See before • PRESET SETUP • REAL TIME [none] • LIVE TIME [none] • IDENTIFY OPTIONS • Identify Settings: • Time [s] 60 • No. of Nuclides: 2 - 4 • Library: SECUR / Customs / Indust. / Medical / Nuclear / OSI • Edit isotope list: e.g. • Cs-137 SCI--- • I-131 SC-M— • Don’t change this isotope list! ADVANCED OPTIONS See next page

  8. Expert mode – advanced mode • STABILISATION • Source stab. status • PSA stab. status • LED stab. status • SETUP DISPLAY / TIME • Display settings • Language: ENG / SPA / FRA / DEU / RUS • BkLight • Contrast • Autom. OFF • Date / Time • CALIBRATION SOURCE • Cs-137 • K-40 MAINTENANCE See next page • DATA LOGGING • Set ON/Off and measurement time

  9. Expert mode – maintenance FACTORY TEST • Hardware test (buttons) • Display test • Alarm light test • Sound test • CHANGE PASSWORD • Set password (confirming password when you enter expert mode again) • Clear password FACTORY DEFAULT reset to factory settings ERASE ALL SPECTRA erase all stored spectra • SHOW STATUS • Version • Battery • Backup battery • High Voltage