BML-D 001 Monitoring. Paolo Iengo Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino, F. Conventi, R. de Asmundis, M.Della Pietra, D. della Volpe, P.I., S.Patricelli , L.Romano , G. Sekhniaidze ). Overview. Plot & Fit V-I Historical Trends of Fit Parameter
E N D
BML-D 001 Monitoring Paolo Iengo Atlas RPC Group Napoli (M. Alviggi, V. Canale, M. Caprio, G. Carlino, F. Conventi, R. de Asmundis, M.Della Pietra, D. della Volpe, P.I., S.Patricelli, L.Romano, G. Sekhniaidze)
Overview • Plot & Fit V-I • Historical Trends of Fit Parameter • Monitoring of Current, HV, Temp. etc • Conclusions
Plot V-I FIT: I(V) = a+bV V<4000 Volt I(V) = a+bV +k (exp(V/c) –1) V>5000 Volt
Plot V-I < 1 July > 1 July
Historical Trend of Linear Slope T = 20 exp(-(T-20)) = 1/12
5 – 15 June 60 µA Currents 11 kV CAEN H.V.
24 June – 8 July Currents CAEN H.V.
Currents 134 A Gas Flow Temperatures Isob. SF6
Currents Isob. Flow
Currents CAEN H.V. 9 – 16 July
Currents CAEN H.V. Temperatures
Conclusions • Behavior of BML-D 001 quite “stable” • Increasing current on one layer due to the problem on isobutane • Delay between HV and “regime” current needs more investigation • Continuous Monitoring of HV, Current, Gas Flow & Env. Parameters is Essential