210 likes | 375 Views
FAMILY RESIDENTIAL Author of the slides: Dr. Robert Cvelbar + , Simon Brlek ++ Institute for Metal Constructions, Lokainvest Case study no. 2. Leonardo da Vinci project no. CZ/06/B/F/PP-168007 WP6 – Case Studies PC 3 – A set of case studies. Content of slides. 1. General information
E N D
FAMILY RESIDENTIALAuthor of the slides: Dr. Robert Cvelbar+, Simon Brlek++Institute for Metal Constructions, LokainvestCase study no. 2 Leonardo da Vinci project no. CZ/06/B/F/PP-168007 WP6 – Case Studies PC 3 – A set of case studies
Content of slides • 1. General information • 1.1. Investment design • 2. Bearing system • 2.1 General description • 3. Actions on structures • 4. Erection • 5. Technical parameters • 6. Interesting construction details
1. General information • Date: 2006 • Price: app. 100.000 EUR • Investor: Darija and Simon Brlek, Mekinje nad Stično 67 • Design studio: Elea IC, www.elea.si • Construction company: Jaris d.o.o., www.jaris.si • Location: suburban, Mekinje nad Stično 67, Slovenia • Materials used: reinforced concrete, timber, steel frame, OSB structural plates, blown-in wood fiber insulation, plaster hardboards, polyethylene foil, decorative facade roughcast, XPS, fasade plates AGEPAN THD, polystyrene, hydroinsulation, plaster, glue, ceramics, ....
1. General information 1.1. Investment design The structure is family house dimensions 12 x 8,2 m with • basement • ground floor and • garret. Main target in design was low energy consumption family residence.
2. Bearing system 2.1. General description The structure is family house with: • concrete basement, • wooden structure with steel frame of the ground floor and • wooden structure of the garret.
2. Bearing system Prefabricated outside walls as timber frame.
2. Bearing system Outside walls as timber frame with the final configuration: 1. Contact facade: 0,6 cm 2. Fasade plate: Agepan THD 6 cm 3. Timber frame structure with blown-in wood fiber insulation: 16 cm 4. OSB plate: 1,5 cm 5. Instalation channel with blown-in wood fiber insulation: 5 cm 6. 2 layers of gypsum plaster board: 2 x 1,25 cm
2. Bearing system • 3x steel beam on steel columns due the earthquake loading, HEA 160, S235JR
2. Bearing system Roof support.
3. Actions on structure Applied actions on structures for the calculation:
3. Actions on structure Applied actions of structure on the foundation plate.
4. Erection • Wooden structure and steel reinforcement of the ground floor is placed on the reinfored concrete plate (15 cm) covered with the hydroinsulation (1 cm), followed with thermal insulation XPS (20cm), PE foil and reinfored concrete plate (20 cm). • Load carrying outside walls were prefabricated frames covered with OSB plates on one side. • Wooden structure of the garret and roof.
4. Erection Thermal insulation of the foundation plate
4. Erection Assembly of the structural elements
4. Erection Covering with the fasade plates.
4. Erection Final shape.
5. Interesting construction details Design of the foundation plate insulation.
5. Interesting construction details Roof support design.
5. Interesting construction details Filling the blown-in wood fiber insulation.
Thank you for your attention! http://fast10.vsb.cz/temtis/en/