An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Optical Networks – Fault Tolerance (Part 2)Dr. ArunitaJaekel

  2. Fault-tolerance in Optical Networks • Faults in Optical Networks • Link failures the most common type of fault, where the fiber constituting a link between two nodes in the network does not permit data transmission. • Node failures • Channel failures • Software failures • Most papers assume single fault scenario.

  3. Fault-tolerance in Optical Networks • Reasons behind faults in optical layer • Fiber cut • Noise introduced by optical signal regenerators and amplifiers • Cable inside a site may get disconnected • Importance of Fault management in optical networks • Large amount of traffic carried by optical channels • Each fiber carries many channels • Failure may lead to huge data loss

  4. Fault-tolerance in Optical Networks • Categorization of fault management schemes Figure 20

  5. Fault-tolerance in Optical Networks • Protection scheme • Recovery scheme determined at design time • Resources are reserved for each possible failure (link or path). • Faster recovery time and guaranteed recovery • Restoration scheme • Recovery scheme determined after the occurrence of fault • Dynamically search for backup path and available wavelength after failure occurrence. • Efficient in utilizing capacity

  6. Fault-tolerance in Optical Networks • Link protection – backup path reserved around each link • Primary path: N8N4N6N1 • The faulty edge N4N6 is replaced by an alternate route N4N7N6. • Backup path: N8N4N7N6N1 N1 N2 N3 C3 C3 N4 N5 C3 C3 X C3 C3 C3 N6 N7 N8 Primary path Backup path Figure 22: Link protection scheme

  7. Fault-tolerance in Optical Networks • Path Protection • In the case of a fault, for each primary lightpath using the faulty component, the corresponding backup lightpath will be set up. • All data carried by each primary lightpath affected by the fault will be switched over to the corresponding backup lightpath. • Primary and backup paths must be edge-disjoint.

  8. Fault-tolerance in Optical Networks • Path Protection – backup path reserved on a end-to-end basis N1 N2 N3 C3 C3 N4 N5 C2 C1 C1 N6 N7 N8 Primary path C2 Backup path Figure 21: Path protection scheme

  9. Primary 2 3 1 4 6 5 Backup Fault-tolerance in Optical Networks • Dedicated path protection • Dedicated Path Protection • The channel used by a backup lightpath is always reserved for a single primary lightpath. Figure 23: 1:1 Protection

  10. Primary 2 3 1 1 4 2 6 5 Backup Fault-tolerance in Optical Networks • Shared Path Protection ( also called backup multiplexing ) Resources may be shared by two or more backup paths if and only if the corresponding primary paths are edge disjoint. Figure 24: 1:N Protection

  11. ILP for Dedicated Path Protection(DPP) • Given: • Physical fiber network G[N, E]. • A set of channels Kon each fiber. • A set Lof existing connections (lightpaths) in the network. • ae,l= 1, if and only if the lthexisting connection uses edge e(ij)on its primary lightpath. • be,l = 1, if the lthexisting connection uses edge e on its backup lightpath. • kl,p(kl,b) = the channel assigned to the lthprimary (backup) path Integer Variables • xe(ye) = 1, if and only if the primary (backup) route of new lightpath uses physical link e. • wk(zk) = 1, if and only if primary (backup) route of new lightpath is assigned channel k. λ1 2 λ1 λ1 1 3 λ2 Existing Lightpaths 4 1  3 2  1 4  2 4  3 31

  12. ILP for Dedicated Path Protection(DPP) Min Subject to: λ1 2 λ1 λ1 1 3 λ2 1 4 1  3 2  1 4  2 4  3 3  1

  13. ILP for Shared Path Protection(SPP) Min 1  3 2  1 4  2 4  3 3  1 λ1 2 λ1 λ1 1 3 1 λ2 4 New variables: de,l = 1, if primary path of new lightpath and lightpathl both used edge e. dl = 1, if primary path of new lightpath has a common edge with lightpathl