Practical clinical chemistry

Practical clinical chemistry. Lab 1. Quality Assurance. Quality Assurance: The coordinate process of providing the best possible service to the patient and physician.

vlad
Download Presentation

Practical clinical chemistry

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Practical clinical chemistry Lab 1

  2. Quality Assurance Quality Assurance: The coordinate process of providing the best possible service to the patient and physician. QAis a complete system which contain quality control. (Right result at right time on right specimen from right patient)

  3. What is quality control? • Quality Control: • The process of monitoring the accuracy and precision of laboratory test with control samples. • A statistical process used to monitor and evaluate analytical process • that produces patient results.

  4. Qc types: Qc can be achieved through: 1- Internal quality control Is a Procedure for utilizing the results of only one laboratory for quality control purpose 2- External quality assessment Is a procedure for utilizing, for quality control purposes, the results of several laboratories which analyze the same specimens.

  5. When errors occur? • Errors occur when there is a loss of accuracy and precision. • A primary goal of quality assurance is to reduce and detect errors or to obtain the best possible accuracy and precision.

  6. Source of error: • All analytical results are subject to errors arising from a variety of causes but it should kept to a minimum • Errors can occur at various stages in the process: • 1- Pre-analytical : occur outside the LAB • 2- Analytical: occur within the lab • 3- Post-analytical: the correct result is generated but is incorrectly recorded in the patient's record

  7. True analytical errors are those which occur during the actual performance of the analysis which can be classified into : 1- Systematic errors. 2- Random Errors.

  8. Systematic errors: • On repeated analysis of the sample we may also find values at wrong level(too high or too low) which can be due tothe analytical methods, technical performance, reagents, measuring equipment and the technicians. There are two varieties of systematic errors, • Constant error • Error In a test system in which the amount of error remains constant throughout the range of the test process. • Proportional error • Error In a test system in which the amount of error increases the concentration of the substance being measured.

  9. Random errors: • Errors or mistakes the occur without prediction or regularity. • Manifest themselves by variations in the results of repeated analysis of the same sample ( either positive or negative errors are usually distributed) • These variations may caused by several variable factors which include variations in apparatus, temperature, weighing, etc., • random error cannot be avoided • Theses random errors can be reduced by more precise methods and more accurate equipment

  10. Method validation: • the ideal analytical method is accurate, precise, sensitive and specific. • Accuracy: • The measure of correctness or truth of laboratory test. • precision: • Agreement between replicate measurements (reproducibility)

  11. Sensitivity • the ability of a diagnostic test to detect very small amounts of the analyte. • Ability to correctly identify individual with disease • Ability to exclude false negative

  12. Specificity • detect the desired analyte without interferences. • Ability to correctly identify individual without disease • Ability to exclude false positive

  13. Linearity • Is the range over which the analytical system exhibit a linear • The highest conc. Can be detected • The measured value from a series of samples solution is linearly proportional to the actual concentration or content of the analyte in the sample solution.

  14. Control, standard, and calibrator • Control A solution that contains the same constituents as those being analyzed in the patient sample • Standard Substance of constant composition and of sufficient purity to be used for comparison purposes. • Calibrator Similar to standard but it is not pure “ contain more than one analyte’.

  15. Interpretation of quality control charts • A variety of statistical control techniques have been used in clinical laboratories. • The levey- jennings control chart has been the most widely used technique. • The control results are plotted on the y-axis. This chart shows the expected mean value by the solid line in the center and indicates the control limits or range of acceptable values by the dashed lines. The usual way of interpreting this control chart is to consider the run to be in control when the control values fall within the control limits, and to be out of control when result exceeds the control limits. levey- jennings control chart

  16. Statistical calculation: • mean • The arithmetic mean is the average. • Standard deviation • Is the distribution range around the mean value. • Percentage coefficient of variation (%cv) • It is the standard deviation expressed in percentage

  17. Westgard qc rules • There are six basic rules in the Westgard scheme. • These rules are used individually or in combination to evaluate the quality of analytical runs. • Most of the quality control rules can be expressed as NL where N represents the number of control observations to be evaluated and L represents the statistical limit for evaluating the control observations. • Thus 13s represents a control rule which is manifested when one control observation exceeds the ±3s control limits

  18. 12s • This is a warning rule that is violated when a single control observation is outside the ±2s limits. • This rule warns that random error or systematic error may be present in the test system. • Must then evaluate the 13S rule

  19. 13s • One QC result outside ±3s • This rule identifies unacceptable random error or possibly the beginning of a large systematic error.

  20. 22s • This rule identifies systematic error only. • The criteria for this rule are:• Two consecutive QC results Greater than 2s on the same side of the mean • Or Both controls in the same run exceed ±2SD • Patient results cannot be reported(rejection rule). • Requires corrective action

  21. R4s • This rule identifies random error only • One control exceeds the mean by –2sd, and the other control exceeds the mean by +2sd • The difference between the two results will therefore exceed 4 sd. • This rule is only to be used within a run not across runs.

  22. 41s • The criteria which must be met to manifest this rule are: • four consecutive qc results for one level of control are outside ±1sd on the same side of the mean, or • both levels of control have 2 consecutive results that are outside ±1sd. • This allows the detection of systemic error • Rejected rule

  23. 10x • These rules are violated when there are: • Ten consecutive qc results for one level of control are on one side of the mean, or • Both levels of control have five consecutive results that are on the same side of the mean (no requirement for SD size). • This allows the detection of systemic error. • Rejected rule

  24. Shift • A shift is sudden consistent change in values in either side of the mean • QC data results are distributed on one side of the mean for 6-7 consecutive days

  25. trend • A trend is a gradual decrease or increase in the values in either side of the mean. • Consistent increase or decrease of qc data points over a period of 6-7 days.

  26. dispersion • Values may be within the acceptable range but are unevenly distributed outside the ±1s limits. • This is indicating a loss of precision and due to random error. a precision problem, or increase in random error, would cause the standard deviation to increase, therefore widening the expected distribution of control