1 / 34

Introduction Why digital? Why dual energy? Experimental setup Image processing and results

A silicon microstrip system with the RX64DTH ASIC for dual energy radiology. Introduction Why digital? Why dual energy? Experimental setup Image processing and results Alvarez-Macovski algorithm Subtraction imaging with contrast medium Conclusion and outlook. The Collaboration.

Download Presentation

Introduction Why digital? Why dual energy? Experimental setup Image processing and results

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. A silicon microstrip system with the RX64DTH ASIC for dual energy radiology • Introduction • Why digital? • Why dual energy? • Experimental setup • Image processing and results • Alvarez-Macovski algorithm • Subtraction imaging with contrast medium • Conclusion and outlook

  2. The Collaboration 1) University of Eastern Piedmont and INFN, Alessandria, Italy L. Ramello; 2) University and INFN, Torino, Italy P. Giubellino, A. Marzari-Chiesa, F. Prino; 3) University and INFN, Ferrara, Italy; M. Gambaccini, A. Taibi, A. Tuffanelli, A. Sarnelli; 4) University and INFN, Bologna, Italy G. Baldazzi, D. Bollini; 5) AGH Univ. of Science and Technology, Cracow, Poland W. Dabrowski, P. Grybos, K. Swientek, P. Wiacek; 6) University of Antwerp, Antwerp, Belgium P. Van Espen; 7) Univ. de los Andes, Colombia C. Avila, J. Lopez Gaitan, J.C. Sanabria; 8) CEADEN, Havana, Cuba A.E. Cabal,C. Ceballos, A. Diaz Garcia; 9) CINVESTAV, Mexico City, Mexico L.M. Montano;

  3. Introduction: why digital ? • Digital radiography has well known advantages over conventional screen-film systems • Enhance detecting efficiency w.r.t. screen-film • Image analysis • Easy data transfer

  4. Based on different energy dependence of different materials Enhance detail visibility (SNR) Decrease dose to the patient Decrease contrast media concentration Introduction: why dual energy ? • Dual energy techniques • GOAL: improve image contrast

  5. E  15-20 keV: Signal from cancer tissue deteriorated by the adipose tissue signal E  30-40 keV Cancer tissue not visible, image allows to map glandular and adipose tissues Example 1: dual energy mammography

  6. Dramatic change of iodine absorption coeff. at K-edge energy (33 keV) Image subtraction (2 images taken below and above the K-edge energy) Example 2: angiography at the iodine K-edge Iodine injected in patient vessels acts as radio-opaque contrast medium

  7. Quasi-monochromatic beams • ordinary X-ray tube + mosaic crystals • instead of truly monochromatic synchrotron radiation • Advantages: cost, dimensions, availability in hospitals • Linear array of silicon microstrips + electonics for single photon counting • Binary readout • 1 or 2 discriminators (and counters) per channel • Integrated counts for each pixel are readout • Scanning required to build 2D image Experimental setup • To implement dual energy imaging we need: • a dichromatic beam • a position- and energy-sensitive detector

  8. Experimental setup: beam (1) Bragg Diffraction on Highly Oriented Pyrolitic Grafite Crystal 1st and 2nd Bragg harmonics  E and 2E are obtained in the same beam Collimator W anode tube

  9. Experimental setup: beam (2) Bragg Diffraction on Highly Oriented Pyrolitic Grafite Crystal Two spatially separated beams with different energies  E-DE and E+DE obtained in 2 separate beams Double slit collimator W anode tube

  10. incident spectra at 3 energy settings … More on the dichromatic beam … spectra after 3 cm plexiglass (measured with HPGe detector)

  11. X-rays N. I. I/O cards PCI-DIO-96 and DAQCard-DIO-24 current pulses 100 m data, control Silicon strip detector Integrated circuit PC Experimental seup: Single Photon Counting System • Fully parallel signal processing for all channels • Binary architecture for readout electronics • 1 bit information (yes/no) is extracted from each strip • Threshold scans needed to extract analog information • Counts integrated over the measurement period transmitted to DAQ

  12. Experimental setup: silicon detector Designed and fabricated by ITC-IRST, Trento, Italy

  13. Detector efficiency • Efficiency calculation • X-ray absorbed if interacts in passive regions • X-ray detected if makes photoelectric effect in active regions • Front geometry • Strip orthogonal to the beam • 70 mm of Al light shield • Edge-on geometry • Strip parallel to the beam • 765 mm of inactive Si • Better efficiency for E > 18 keV

  14. Detector 1 2 5 4 3 Experimental setup: RX64 chip Cracow U.M.M. design - (28006500 m2) - CMOS 0.8 µm process (1) 64 front-end channels a) preamplifier b) shaper c) 1 or 2 discriminators (2) (1 or 2)x64 pseudo-random counters (20-bit) (3) internal DACs: 8-bit threshold setting and 5-bit for bias settings (4) internal calibration circuit (square wave 1mV-30 mV) (5) control logic and I/O circuit (interface to external bus)

  15. Experimental setup: PCB detector pitch adapter ASICs • PCB: • - One 400 strip detector • - Pitch adapter • - 6 RX64 chips • 384 equipped channels - connector to DAQ card 2 protoype detectors: • 6 x Single threshold RX64 • 6 x Dual threshold RX64

  16. System calibration setup in Alessandria Fluorescence target (Cu, Ge, Mo, Nb, Zr, Ag, Sn) Detector in Front config. Cu anode X-ray tube → X-ray energies = characteristic lines of target material

  17. Mo K Sn K Ge K Ag K Cu K MoK Ag K Rb Ka Sn K System calibration 241Am source with rotary target holder (targets: Cu, Rb, Mo, Ag, Ba) Cu-anode X-ray tube with fluorescence targets (Cu, Ge, Mo, Ag, Sn)

  18. Dual energy imaging • K-edge subtraction imaging with contrast medium • Cancel background structures by subtracting 2 images taken at energies just below and above the K-edge of the contrast medium • Suited for angiography at iodine (gadolinium) K-edge • Cancel background structures to enhance vessel visibility • Possible application in mammography (study vascularization extent) • Hypervascularity characterizes most malignant formations • Dual energy projection algorythm • Make the contrast between 2 chosen materials vanish by measuring the logarithmic transmission of the incident beam at two energies and using a projection algorithm [Lehmann et al., Med. Phys. 8 (1981) 659] • Suited for dual energy mammography • remove contrast between the two normal tissues (glandular and adipose), enhancing the contrast of the pathology • Single exposure dual-energy mammography reduces radiation dose and motion artifacts

  19. X-ray tube with dual energy output Phantom Detector box with 2 collimators Angiography setup • X-ray tube + mosaic crystal and 2 collimators to provide dual-energy output • - E1= 31.5 keV, E2 =35.5 keV (above and below iodine k-edge) • Detector box with two detectors aligned with two collimators • Step wedge phantom made of PMMA + Al with 4 iodine solution filled cavities of 1 or 2 mm diameter

  20. E = 31.5 keV E = 35.5 keV logarithmic subtraction Phantom structure not visible in final image Angiographic test results (I)

  21. Conc = 370 mg / ml Conc = 92.5 mg / ml Conc = 23.1 mg / ml Possible decrease of iodine concentration keeping the same rad. dose Angiographic test results (II)

  22. Dual Energy Angiography Digital Subtraction Angiography smaller cavity (=0.4 mm) visible in DEA and not in DSA Results with a second phantom Phantom Iodine conc. = 95 mg/ml

  23. Dual energy projection algorithm The mass attenuation coefficient μ of any material  at a given energy E is expressed as a combination of the coefficients of any two suitable materials  and : The logarithmic attenuation M = μξtξ of the material of thickness tξ is measured at two different energies: low (El) and high (Eh): A1 and A2 represent the thicknesses of the two base materials which would provide the same X-ray attenuation as material ξ.

  24. Dual energy projection algorithm I0 ξ ψ R I1 I2 M1 C 90° C  1  The logarithmic attenuation M in a given pixel can be represented as a vector having components A1 and A2 in the basis plane, the modulus will then be proportional to the gray level of that pixel  If a monochromatic beam of intensity I0 goes through material ξwhich is partly replaced by another material ψ … … then the vertexes of log. attenuation vectors M2 (material ξ) and M1 (mat. ξ+ψ) lie on a line R which is defined only by the properties of materials α, β, ξandψ. Projecting along direction C, orthogonal to R, with the contrast cancellation angle : M2 A2 2 … it is possible to cancel the contrast between materials ξand ψ: both M1 and M2 will project to the same vector  A1

  25. Mammographic phantom • Three components: polyethylene (PE), PMMA and water to simulate the attenuation coeff. m (cm-1) of the adipose, glandular and cancerous tissues in the breast  S. Fabbri et al., Phys. Med. Biol. 47 (2002) 1-13

  26. Correct for: HE and LE images 16 keV 32 keV • pixels with huge n. of counts (bad counter conversion) • dead pixels • X-ray beam fluctuations • subtract high threshold image from low threshold one • correct for spatial inhomogeneities of beam and detector extracted from flat-field profiles Image processing (1) Measured (raw) Low thr. High thr.

  27. Image processing (2) 16 – 32 keV 18 – 36 keV 1= PMMA 2=water 3=PE 4=(water+PE) • Low statistics due to: • 2nd order harmonic • dectecting efficiency

  28. Top View Side View Simulation with MCNP • MCNP-4C simulation with • ENDF/B-VI library • Photons and electrons tracked through the phantom and the detector (including the inactive region in front of the strips) • Energy deposition in each strip recorded • histogram of counts vs. strip number filled 1=detector 2=PMMA 3=water 4=PE

  29. simulation 16 – 32 keV Experiment vs. Simulation (1) RX64DTH 16 – 32 keV

  30. Experiment vs. Simulation (1)

  31. MCNP simulation RX64DTH 16 – 32 keV Results (1): SNR vs. proj. angle Theoretical cancellation angles: PMMA-water 36.5° PE-water 40.5° PMMA-PE 45° Cancellation angle for a pair given by SNR=0

  32. Results (2): SNR summary * Previous version of ASIC, exposure with about 2x more incident photons

  33. PMMA-water cancellation PMMA-PE cancellation Results (3): Projected images RX64DTH 16 – 32 keV simulation 16 – 32 keV

  34. Conclusion and Outlook • We have developed a single photon counting silicon detector equipped with the RX64DTH ASIC, with two selectable energy windows • The energy resolution of 0.8 keV (rms) is well adapted for dual energy mammography and angiography • We have performed mammography imaging tests with a three-material phantom • We have demonstrated the feasibility of contrast cancellation between two materials, enhancing the visibility of small features in the third one • We have performed angiography imaging tests with 2 different phantoms and iodine contrast medium • We have demonstrated the feasibility of logarithmic subtraction between two images, enhancing contrast of small vessels also with lower iodate solution concentrations • OUTLOOK: • Increase photon statistics at high energy, optimize exposure conditions • New detector materials, CZT? • Tests with a more realistic mammographic phantom