1 / 20

EVENT LOGGING AND VIEWING

Learn how to log and view event logs for HP storage systems, including management agent logs, controller events, disk events, and more.

walshc
Download Presentation

EVENT LOGGING AND VIEWING

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EVENT LOGGING AND VIEWING

  2. EVENT LOGS • LOGS • MANAGEMENT AGENT LOGS • CONTROLLER EVENTS • DISK EVENTS • PORT EVENTS • LOOP EVENTS • STORAGE CELL EVENTS • CONTROLLER TERMINATION EVENTS • LAST FAILURE CODES HP – For Internal Use Only

  3. Management Logical Disk (MLD) • Disk Metadata saved on quorum disks on the Initialized Storage System that stores persistent state information • Management Agent Events • Event configuration list • Trap host list • Elements of view list • License list (for all storage systems) • MLD mirrored on Quorum disks • Reads from single quorum disk • Updates to all quorum disks • ~ 33000 Blocks HP – For Internal Use Only

  4. HSV Event Handling and Logs • Events Generated: • State change in hardware • State change in logical element • Procedure completion • Environmental change • Operational failure • SWMA polls Storage System for events HP – For Internal Use Only

  5. MANAGEMENT EVENT POLLING • Events collected and processed every 45 seconds • May impact the HSV Element Manager performance • May make the Management Appliance appear as slow or hung • Ifthe HSV is very busy and the ping to obtain the lock fails, it waits for the next cycle to collect the controller events HP – For Internal Use Only

  6. VIEWING LOG FILES • Viewed from HSV Element Manager • More details from “download more details” • Log files can be downloaded via ‘Get Log File’ button • Management Agent saved as ASCII files • Controller and Termination Event saved as Binary files • Must be decoded by HSVET tool • Must be decoded by HSVET tool HP – For Internal Use Only

  7. HP – For Internal Use Only

  8. HP – For Internal Use Only

  9. HP – For Internal Use Only

  10. HP – For Internal Use Only

  11. HP – For Internal Use Only

  12. HP – For Internal Use Only

  13. HP – For Internal Use Only

  14. HP – For Internal Use Only

  15. Severity: Normal -- informational in nature. A physical disk drive has reported a check condition error. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. If the bay field contains a value other than zero, the location of the physical disk drive is contained in the rack_num, dencl_num, and bay fields. If the bay field contains a zero, the location of the physical disk drive is unknown and the content of the rack_num and dencl_num fields is undefined. The rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. The sense data obtained from the physical disk drive as a result of the check condition error is contained in the error field. EIP09 - Fibre Channel Services Physical Disk Drive/Mirror Port Error An error was encountered while attempting to access a physical disk drive or the mirror port. Event Log Packet Event Specific Information flags (Flags) Flag field bits: 00000011 Time has been set on this HSV110 controller: TRUE Time has been synchronized with all HSV110 controllers in the Storage System: TRUE Event sequence number reset occurred: FALSE Event reported out of sequence due to Final Event Block reconciliation: FALSE Event requeued following restart or resynchronization: FALSE Pad to fill byte: 0 HP – For Internal Use Only

  16. revision - Structure revision number: 1 [0x01] count - Event specific information size in bytes: 148 [0x94] sequence_number - Sequence number assigned to the event: 89029 [0x015bc5] sw_version - HSV110 controller software version number string: 2001 baselevel_id - HSV110 controller baselevel build string: ENT-V2001 ctrlr_model_id - HSV110 controller model string: HSV110 reporting_ctrlr - Storage System Management Interface Handle of HSV110 controller that reported the event: Noid: 0 IdType: 7 IdLength: 8 UUID: 5005-08b4-0001-45ab-0000-0000-0000-0000 report_time - Time event was reported: Date: 26-Dec-2002 Time: 10:25:17:119 report_location - Location of event report call: 1083784 [0x108988] header (Header Information) ** NOTE: The following is part of a UNION with more than one interpretation. You will need to determine which union value is relevant. ** START UNION: ( u - Event Code Union ) ** ec (Event Code) eiptype - Event Information Packet Type Code: 9 [0x09] cac - Corrective Action Code: 0 [0x00] Corrective Action: No action necessary. evnum - Event Number: 2 [0x02] scid - HSV110 Controller Software Component Identification: 6 [0x06] ** UNION OR: ( u - Event Code Union ) ** value - Event Code Value: 100794377 [0x06020009] ** END UNION: ( u - Event Code Union ) ** revision - Packet revision number: 0 [0x00] type - Packet type: 9 [0x09] count - Number of bytes in packet: 84 [0x54] HP – For Internal Use Only

  17. device - UUID of physical disk drive associated with the event: 2000-0004-cf44-7114-0000-0000-0000-0000 cerp_id - HSV110 controller enclosure rear panel Fibre Channel port attached to the physical disk drive or mirror port: DP-2A reserved - Reserved: 0 [0x00] port - HSV110 controller internal Fibre Channel port number attached to the physical disk drive or mirror port: 2 [0x02] dencl_num - Enclosure where the physical disk drive is located: 10 [0x0a] al_pa - AL_PA of the physical disk drive or mirror port: 202 [0xca] rack_num - Rack where physical disk drive is located: 0 [0x00] bay - Enclosure bay where the physical disk drive is located: 9 [0x09] fed_class - Fibre Channel Exchange Descriptor class: 48 [0x30] ** NOTE: The following is part of a UNION with more than one interpretation. You will need to determine which union value is relevant. ** START UNION: ( cmd - Command Descriptor Block issued ) ** bytes - CDB as bytes: [ 0]: 47 [0x2f] [ 1]: 0 [0x00] [ 2]: 1 [0x01] [ 3]: 32 [0x20] [ 4]: 96 [0x60] [ 5]: 0 [0x00] [ 6]: 0 [0x00] [ 7]: 16 [0x10] [ 8]: 0 [0x00] [ 9]: 0 [0x00] [10]: 0 [0x00] [11]: 0 [0x00] [12]: 0 [0x00] [13]: 0 [0x00] [14]: 0 [0x00] [15]: 0 [0x00] HP – For Internal Use Only

  18. sense_data (Sense data by field) Flag field bits: 11110000 Offset 0, Bits 0-6 -- Error Code: 70 Offset 0, Bit 7 -- Valid: TRUE segment - Offset 1 -- Segment: 0 [0x00] Flag field bits: 00000001 Offset 2, Bits 0-3 -- Sense Key: 1 Offset 2, Bit 4 -- Reserved: FALSE Offset 2, Bit 5 -- Incorrect Length Indicator: FALSE Offset 2, Bit 6 -- End of Medium: FALSE Offset 2, Bit 7 -- Filemark: FALSE info_0 - Offset 3 -- Information[0]: 1 [0x01] info_1 - Offset 4 -- Information[1]: 32 [0x20] info_2 - Offset 5 -- Information[2]: 109 [0x6d] info_3 - Offset 6 -- Information[3]: 64 [0x40] add_length - Offset 7 -- Additional Sense Length: 10 [0x0a] cmd_specific - Offsets 8-11 -- Command Specific Information: [0]: 0 [0x00] [1]: 0 [0x00] [2]: 0 [0x00] [3]: 0 [0x00] ** NOTE: The following is part of a UNION with more than one interpretation. You will need to determine which union value is relevant. ** START UNION: ( asc_ascq - ASC/ASCQ Union ) ** asc_ascqb (Offsets 12-13 -- Additional Sense Code (ASC)/Additional Sense Code Qualifier (ASCQ)) asc - Offset 12 -- ASC: 24 [0x18] asq - Offset 13 -- ASCQ: 1 [0x01] ** UNION OR: ( asc_ascq - ASC/ASCQ Union ) ** asc_ascqw - Offsets 12-13 -- Combined ASC/ASCQ: 280 [0x0118] HP – For Internal Use Only

  19. TOOLS • HSVET • YAPP • YET ANOTHER POST PROCESS ANALYZER • TAKES TEXT OUTPUT FROM HSVET • BUILDS BRIEF, SUMMARY, TIMESTAMP,SPREADSHEETS • YEAH • IMPROVED YAPP – yet another event analyzer for HSV’s • TAKES INPUT FROM WINDOWS EVENT,HSVET,SCEVENT • Web • http://techport.tay.cpqcorp.net/ • http://cybrary.inet.cpqcorp.net/ • HSV service manual HP – For Internal Use Only

More Related