1 / 6

TOF Calibration ++

TOF Calibration ++. Y. Karadzhov. List of the available TOF Calibrations. December 2009 – corresponds to the runs before 01466 (11 Feb 2010) . February 2010 - corresponds to the runs between 01466 and 01558 (11 Feb - 24 Apr 2010) .

Download Presentation

TOF Calibration ++

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TOF Calibration ++ Y. Karadzhov

  2. Y. Karadzhov, MICE CM28 5/10/10 List of the available TOF Calibrations • December 2009 – corresponds to the runs before 01466 (11Feb2010). • February 2010 - corresponds to the runs between 01466 and 01558 (11Feb - 24Apr2010). • Current calibration - corresponds to the runs after 01558. This is now the default calibration in G4MICE. • August 2010 – additional calibration that corresponds to the same run period as the default one. Be careful !!! This calibration is not complete – • NO CALIBRATION FOR TRIGGER IN TOF0 • NO CALIBRATION FOR TOF2 • Nothing unexpected in the performance of the TOF detectors.

  3. Y. Karadzhov, MICE CM28 5/10/10 Status of the TOF Calibration • Time resolution after the calibration: • TOF0 – 51ps; • TOF1 – 58ps; • TOF2 – 52ps. Run 2244 Slide from my talk at CN27 Be careful. These distributions depend on the beam shape, therefore the resolution is different in the different runs! Also these distributions are blind for some systematic effects.

  4. Y. Karadzhov, MICE CM28 5/10/10 Runs 2711, 2712, 2713 e+ trigger TOF1 Runs 1788, 1789, 1790 e+ trigger TOF0 Runs 2240, 2243 π→µ trigger TOF1 Runs 2375, 2377 π→µ trigger TOF0 Run 2887 10 V Reconstruction efficiency

  5. Y. Karadzhov, MICE CM28 5/10/10 Interface between TofRec and Configuration Database • The client code for communication between G4MICE and Configuration Database is now improved and debugged. • The TOF Reconstruction can now communicate with the Configuration Database. For the moment this is used only to set the proper trigger at the beginning of the run. • Next step is to use DB to load the proper calibration and cabling. • See DBExample application for an example how to get information from the Configuration Database.

  6. Y. Karadzhov, MICE CM28 5/10/10 Conclusions • The performance of the TOF detectors is stable , but the resolution depends from the beam profile. • Intrinsic inefficiency of the reconstruction is stable. • Interface between TofRec and Configuration Database is almost done. • Documentation and example application are under development.