RF measurements during long MD in Week 17 23 & 25 April 2012

RF measurements during long MD in Week 17 23 & 25 April 2012. Faraday Cage : T. Argyropoulos , T. Bohl , J . E. Muller, E. Shaposhnikova CCC : H. Bartosik , Y . Papaphilippou , G. Rumolo , B . Salvant , SPS OP + …. SPSU-BD 31/05/2012. MD aims.

wells
Download Presentation

RF measurements during long MD in Week 17 23 & 25 April 2012

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RF measurements during long MD in Week 17 23 & 25 April 2012 Faraday Cage: T. Argyropoulos, T. Bohl, J. E. Muller, E. Shaposhnikova CCC: H. Bartosik, Y. Papaphilippou, G. Rumolo, B. Salvant, SPS OP + … SPSU-BD 31/05/2012

  2. MD aims • Single bunch studies in nominal (Q26) and low γt (Q20) optics. • Intensity threshold comparison in single RF between the two • optics with and without phase loop. • scan of the relative phase between the two RF systems (φ800) • with and without phase loop in nominal intensities (~1x1011). • Few remarks: • Many problems (23rd - PS POPS, 25th - 2 RF TX were tripping)  • limited the number of data acquired. • MDs on different nights  not the same conditions for the comparison • (voltage programs, long. dampers etc.)

  3. Q20 – MD on 23/04 – single RF • injected bunch lengths (~3.95 ns) • V200 programmed for constant bucket area of 0.65 eVs (5.25 MV at flat bottom) • with injection at 3 MV and rise to 7 MV at flat top • no controlled emittance blow –up. • low longitudinal emittances (~ 0.33 eVs) at flat bottom • long. dampers ON • total losses ~ 5 % Bunch length evolution along the cycle Phase loop OFF • Intensity ~ 1.8x1011 • Instability starts at ~ 15.7 s • Intensity ~ 1.70x1011 • stable • jump in bunch lengths after 15 s • for some cases (and bunch peak) • threshold is higher than • 1.5x1011 p but not enough • measurements to define it • accurately • dipole oscillations (from bunch • profiles) don’t show much • Small improvement with • phase loop ON

  4. Q26 – MD on 25/04 – single RF Voltage program • injected bunch lengths (~3.7 ns) • no controlled emittance blow –up. • low longitudinal emittances (~ 0.32 eVs) at FB • long. dampers OFF • very few good measurements due to RF TX and • time limit (+ correction of chromaticity) Bunch length evolution along the cycle Phase loop OFF • more time is needed to damp the initial oscillations • threshold seem to be around 1.0x1011 p? • (mainly from visual observations) • similar with phase loop ON • Intensity ~ 0.75x1011 • stable along the ramp

  5. Summary plots (preliminary) Δτ : bunch length amplitude oscillations during the ramp better analysis of these files is needed due to scope saturation The horizontal line in the plots indicates the noise level

  6. Conclusions – future plans • Q20 : intensity threshold > 1.5x1011 • Q26 : intensity threshold ~ 1.0x1011(?) • analysis of the latest measurements (last week) showing lower threshold in • Q20 (1.0x1011)  compare the parameters between the MDs (V200, εL, τ …) • chromaticity control for highest intensities • define the energy threshold N ~ 1/E5/4 • more statistics is needed to define accurate the thresholds!