Current status of the bulk and coating research in Jena

This article provides an overview of the current status of the bulk and coating research in Jena, including cryogenic Q-factor measurement setup, temperature dependence of Q-factor in silicon bulk materials, and investigations on multilayer coatings. The effects of different doping levels, impurities, and crystal orientations are also discussed.

wleigh
Download Presentation

Current status of the bulk and coating research in Jena

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Current status of the bulk and coating research in Jena SFB TR 7

  2. Overview • - Cryogenic Q-factor measurement setup • - Temperature dependence of the Q-factor / loss of silicon bulk materials • + different doping levels • + impurities • + crystals orientations • - Single and multilayer loss dependence on crystalline quartz bulk material • - Cantilever setup and first coating investigantions

  3. 1 Q Φ = f0 amplitude amplitude Df time frequency Measuring Technique Determination of the Q-factor via amplitude ringdown … or bandwidth measurement

  4. Measuring Technique Capacitive excitation and interferometric read-out Other used read-out techniques: - capacitive - reflective (splitted photodiode) - fiber

  5. Environment forBulk Material Research Requirements for cryogenic Q-measurements - low pressure to avoid pressure damping - wide temperature range - long term stability in: > temperature (± 0.2K for hours) > seismic isolation - low external damping due to the suspension

  6. Ø 300 mm 5 1 500 mm 2 3 4 Suitable for bulk and cantilever Q-factor measurements !!! Environment forBulk Material Research Experimental Setup Cryostat 1 probe chamber 2 experimental platform 3 LHe tank (49 l) 4 LN2 tank (62 l) 5 heat radiation shields > T = 5…325 K ΔT = ± 0.1 K > p < 3x10-6 mbar > LHe hold time of 36 h

  7. Dissipation peaks due to impurities in silicon bulk materials phonon-phonon Φmin = 2.2 x 10-9 @ 5.8 K impurities/ defects Silicon, Ø 3” x 12 mm

  8. mechanical Q-factor Temperature [K] “flat” profile at low temperatures silicon (FZ), Ø 6“ x 96 mm dips between 100 and 300K

  9. 1st measurements on silicon samples with different doping levels • 5 samples with a resitivity between 10mΩcm…10kΩcm available silicon, Ø 4” x 99 mm

  10. Coating/grating research on bulk material samples • quartz substrate • grating structure (as will be used) • 1st layer silica • multilayer cryst. quartz,  3“  12 mm

  11. Coating/grating research on bulk material samples substrate + grating + grating + 200 nm SiO2 + graing + 200 nm SiO2 + HR cryst. quartz,  3“  12 mm, 11670 Hz

  12. Coating/grating research on bulk material samples Extracted coating/grating losses Nawrodt et al. New J. Phys. 9 (2007) 225 Higher sensitivity using cantilevers?

  13. Cantilever Coating Research

  14. Cantilever setup for the “large” cryostat 4 3 2 1 1 massive base plate 2 cantilever clamping blocks 3 excitation structure mount 4 cantilever

  15. Excitation Wait Ringdown Measurementprocedure: C1 C2 C3 C4

  16. • available frequency range: 20 Hz …. 90 kHz • losses at the thermoelastic limit

  17. 1st results of tantala coated cantilevers

  18. 1st results of tantala coated cantilevers 500 nm tantala deposited by e-beam evaporation

  19. 1st results of silica coated cantilevers Mechanical loss comparision of two thermal oxide layers (170nm and 400 nm)

  20. New cryostat for coating research • Probe chamber dimensions: Ø 220 mm x 80 mm • T = 5…325 K • p < 3x10-6 mbar • 7,5l @ LN2 tank • 6,5l @ LHe tank

  21. Conclusions - 2 independent cryostats for Q-factor measurements on bulk materials and cantilevers - 1st of 5 different doped silicon bulk samples is almost finished - the influence to the Q-factor of grating and a multilayer stack on cryst. quartz substrate was shown