1 / 17

Detectors for Tomorrow and After Tomorrow …

Amos Breskin Radiation Detection Physics Group Weizmann Institute. Detectors for Tomorrow and After Tomorrow …. photomultiplier. Gas. E. e. Liquid. Xe. photomultiplier. WIMP. Zn characteristic X-ray. Prostate. Tumor. X-ray beam. Zn . Rectal wall. X-ray detector .

xaria
Download Presentation

Detectors for Tomorrow and After Tomorrow …

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Amos Breskin Radiation Detection Physics Group Weizmann Institute Detectors for Tomorrow and After Tomorrow… Amos Breskin

  2. photomultiplier Gas E e Liquid Xe photomultiplier WIMP Zn characteristic X-ray Prostate Tumor X-ray beam Zn Rectal wall X-ray detector Scientific activities Research topics:  Basic detection-related phenomena: New detector concepts  Detector applications: HEP(LHC, ILC, RHIC); “Astro”(DM, SN); Homeland security… Noble-liquid detectors Optical-TPC MAIN INTEREST: GAS-AVALANCHE DETECTORS Gas photomultipliers Ionization patterns e- multipliers n-imaging Amos Breskin DNA damage Prostate cancer

  3. CERN-RD51 Amos Breskin

  4. Thick Gas Electron Multiplier (THGEM) ~ 10-fold expanded GEM GOAL: simple detector with moderate (sub-mm) resolution A.B. et al. Weizmann THGEM 1e- in E 104-105e-s out Double-THGEM: 10-100 higher gains Thickness 0.5-1mm SIMPLE, ROBUST, LARGE-AREA Printed-circuit technology* Effective single-electron detection Few-ns time resolution Sub-mm position resolution >MHz/mm2 rate capability Cryogenic operation: OK Broad pressure range: 1mbar - few bar • * production: • CERN PCB workshop • Print Electronics, Israel Amos Breskin

  5. UV photon CsI photocathode e- Segmented readoutelectrode THGEM Double-THGEM photon-imaging detector RICH • Important FACTS for RICH: • Single-photon sensitivity • Simple, robust, compact, large area • Fast, good localization • Photon detection efficiency : • ~ 20% @ 170 nm • Lower discharge probability than • MWPC/CsI UV detector & faster • recovery Currently R&D for upgrade of CERN-COMPASS RICH S. Dalla Torre, INFN Trieste Amos Breskin

  6. Digital Hadron Calorimetry for ILC (If) ILC: Precision studies of new physics Hadron calorimetry requires 2-fold improved JET-energy resolution: present 60%/E  30%/E Digital calorimetry @ SiD: Sampling jets + advanced pattern recognition algorithms  Very high-precision jet energy measurement. CALICE simulations: σ/Ejet ~3-4% Fe Requires: thin, efficient, highly-segmented, compact, robustsampling elements.candidates: RPC, D-GEM, Micromegas, THGEM ~7mm Fe Amos Breskin With Andy White (UTA) + Coimbra & Aveiro

  7. Few-mm thin, THGEM-based sampling elements Ne/5%CH4 - High efficiency (>96%/98%) with minimal multiplicity (~1.1/1.2) for muons - Discharges: rare; do not affect electronics- Micro-discharges: do not affect performance - Total thickness (excluding electronics) : 5-6 mm. Underway: optimization studies & R&D on large-area detectors. A competitive robust technique Amos Breskin

  8. cryogenic gas-photomultipliers (GPM) fornoble-liquid scintillators - Generic R&D - Compton camera for medical imaging - UV detectors for DM search (XENON, DARWIN) - Combined fast-neutron & Gamma radiography Amos Breskin

  9. GPM: Dark Matter search Two-phase XENON1t Dark Matter Detector concept RD51: Weizmann/Nantes/Coimbra GPMDetector Ne/CF4 E. Aprile/XENON (incl. Weizmann) UV-window S2 Secondary scintillation EG e- Xe-gas ? LXe WIMP interaction EL Primary scintillation S1 Vacuum Photodetectors PMTs or QUPID LXe UV-window 1m GPMDetector S2/S1  background rejection XENON100Kg: running with PMTs! PROBLEM: exorbitant cost of future multi-ton detectors! Amos Breskin

  10. Great Challenge: Combinedg/n imaging detectors Detection of explosives & nuclear materials possibly thin capillaries filled with liquid xenon (LXe) • LXe SCINTILLATOR: • - High density (3 g/cm3) • - Fast (2ns) • - Good spectral match w • CsI-photocathode: • QE~30% @ 175nm • 3cm LXe: high efficiencies: • n: 15-25% • g: 30-40% 11B(d,n)12C 10m TOF: Gammas: ~30ns Fast-n: ~200-500ns  “Moderate” electronics Combined gamma & fast-neutron imaging detector. Gammas and neutrons interact with liquid-xenon; the resulting UV photons are detected with a double-THGEM, CsI-coated gaseous photomultiplier. Amos Breskin

  11. Cryo-GPM with LXe GPM: THGEM/PIM/Micromegas Duval 2011 JINST 6 P4007 GPM Gain 106 @ 170K 200 ns 200 ns FIRST Scintillation induced signals in LXeby 5.5MeV alphas GPM vs PMT@ 173K INTENSE R&D in a novel LXe Cryostat @ Weizmann Amos Breskin

  12. Weizmann Institute Liquid Xenon Facility (WILiX) TPC-GPM testing ground L Arazi, M Rappaport GPM guide, gas, cables Basic consideration: allow frequent modifications in GPM without breaking the LXe equilibrium state GPM load-lock Gate valve Xe liquefier Xe heat exchanger GPM TPC Inner chamber (LXe) Vacuum insulation Amos Breskin

  13. Towards single-phase TPCs • Simpler techniques? • Sufficient signals? • Lower thresholds? • Cheaper? • How to record best scintillation & ionization S1, S2? Amos Breskin

  14. Cascaded Liquid Hole-Multipliers LHM • Modest charge multiplication + Light-amplification in sensors immersed in the noble liquid, applied to the detection of both scintillation UV-photons (S1) and ionization electrons (S2). • UV-photons impinge on CsI-coated THGEM electrode; • extracted photoelectrons are trapped into the holes, where high fields induce electroluminescence (+possibly small charge gain); • resulting photons are further amplified by a cascade of CsI-coated THGEMs. • Similarly, drifting S2 electrons are focused into the hole and follow the same amplification path. • S1 and S2 signals are recorded optically by an immersed GPM or by charge collected on pads. Light or charge readout (GPM or pads) E CsI E E TPC Anode S2Ionization electrons S1 photon Liquid xenon • Holes: • Small- or no charge-gain • Electroluminescence (optical gain) Amos Breskin

  15. S1 & S2 with LHM Liquid xenon Detects S1&S2 Detects S1&S2 A dual-sided single-phase TPC DM detector with top, bottom and side THGEM-LHMs. The prompt S1 scintillation signals are detected with all LHMs. The S2 signals are recorded with bottom and top LHMs. • Highlights: • Higher S1 signals  lower expected detection threshold • Shorter drift lengths lower HV applied & lower e- losses Amos Breskin

  16. CSCADED LHMs L LHM LHM E C LHM C LHM S1, S2 LHM C S1 C Liquid xenon LOW HV for large-volume Relaxed electron lifetime Need: low radioactivity and pad-readout Amos Breskin

  17. SUMMARY • Advances in Detector Physics • Main trend: THGEM R&D, production and applications • RT: RICH & DHCAL • CRYO: UV photons & charge detection in noble liquids • for: DM, Medical, Inspection Amos Breskin

More Related