Store Summary. Tevatron Coordinator - FNAL. 10/21/2019. The Numbers. The lumi chart. Problems. Pbar long blowup at the beginning of stores RF pond water pressure – cleaned strainers CDF lumi readback problems TEL trips (swapped IP power supply) A2 lead flow - orifice changed

xia
Download Presentation

10/21/2019

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Store Summary Tevatron Coordinator - FNAL 10/21/2019

  2. The Numbers

  3. The lumi chart Tevatron Coordinator - FNAL

  4. Problems • Pbar long blowup at the beginning of stores • RF pond water pressure – cleaned strainers • CDF lumi readback problems • TEL trips (swapped IP power supply) • A2 lead flow - orifice changed • A4 quench (St# 7296) due to cryo control power • E4 Quanch @160GeV, not understood (adjusted chroms) Tevatron Coordinator - FNAL 10/21/2019 4

  5. Studies/Work Completed • Tune, coupling & chromaticity adjustments for ramp and squeeze • Separator scans (+1% Lumi at CDF) • D0 IP moved, orbit stab corrector change reverted • Direct chromaticity measurements on ramp & squeeze Tevatron Coordinator - FNAL 10/21/2019 5

  6. D0 IP Tevatron Coordinator - FNAL

  7. Ghost line quench? Tevatron Coordinator - FNAL

  8. IPM work • Changed to new HV ON routine with better diagnostics • By code archeology, found that measurements which failed HV test were not properly discarded • Fixed, but it seems this was not the cause of the fluctuating signal • Added automatic front-end hard reset if persistent front-end error detected • Added hard abort after 10 consecutive HV timeouts • To save MCP, and avoid constant HV ON cases. • Caused issue with proton injection, fixed temporarily with special “injection wait” SPEC • Timing scan (see pic) • Seems bad timing may be the cause of the correlation between detected signal strength and sigma • Found one board off by one sample, causes cut profiles. • To be addressed Tevatron Coordinator - FNAL

  9. IPM timing scan Tevatron Coordinator - FNAL

  10. Board sync issue Related to new timing delay value? Race condition? Tevatron Coordinator - FNAL

  11. Studies • Redo IPM EOS with better vacuum datalogging (15mins) • T980 (2h, daytime) • Tune Mult (2h) • B48 separator flourinert re-fill (between stores) Tevatron Coordinator - FNAL