370 likes | 553 Views
Indoor aerosol behaviour Measurements performed by the AEROSOL LABORATORY. Jiří Smolík 1 , Pavel Moravec 1 , Jaroslav Schwarz 1 , Vladimír Ždímal 1 , Elin Dahlin 2 , Yannis Drossinos 3 , Mita Lapi 4 and Mihalis Lazaridis 5
E N D
Indoor aerosol behaviourMeasurements performed by the AEROSOL LABORATORY Jiří Smolík1, Pavel Moravec1, Jaroslav Schwarz1, Vladimír Ždímal1, Elin Dahlin2, Yannis Drossinos3, Mita Lapi4 and Mihalis Lazaridis5 1Institute of Chemical Process Fundamentals AS CR, Praha, 2Norwegian Institute for Air Research (NILU), Kjeller, 3European Commission Joint Research Centre, Ispra, 4Fondazione Lombardia per l'Ambiente, Milan, 5Technical University of Crete, Chania
Instruments • NanoSMPS: 3 nm - 1 m • SMPS: 7 nm - 1 m • APS: 0,7 m – 20 m (0,5 m - 20 m) • BLPI: 10 size fractions, 0,04 - 10μm • T, RH, P
DMA1 DMA2 APS AC/DC CPC UCPC PC1 PC2 PC3 PC4 Set-up T,P RH In Out T,P RH
Czech Republic Empty office, ICPF, Prague January 2002
Norway Family house, Steinborgveien, Oslo 3.-14.6.2002
Italy Office of the Fondazione Lombardia per l’Ambiente Milan centre 8.-23.10.2002
Czech Republic Apartment, ICPF, Prague 16.-29.11.2002