An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ENG4000 Muscle Sensing for Data Analysis and Treatment Aysar Khalid, Hassan Chehaitli, Mohammad AryanpourGroup 5 Course Director & Advisor: Prof. E. Ghafar-Zadeh Mentor: Mourad Amara

  2. Motivation • Detecting muscle electrical activity using sensors • Autonomous solution that provides data on muscle fatigue, injury, form/posture • Current sensing technology is limited in accuracy • Applications for seniors/elderly health, athletes, ‘quantified’ self

  3. Background • Current techniques (EMG) produces weak signal and expensive • EMG can be thought as 1 dimensional (only measures signal not leg shape) • Capacitance signals can detect changes of leg shapes during motion (Zheng et. al, 2013)

  4. Methodology • Mask leg shape (Cbody) with an array of electrodes • Apply constant frequency signal with constant voltage on one side of electrode mask (electrode1) • Pick up signal from other side electrode (electrode2) • Need a matching impedance (Z) to ensure max power transfer between both electrodes

  5. Methodology (continued) • Raw signal is a sinusoid wave with constant frequency (100 kHz) and varying A -> unsuited for direct sampling • Thus signal is converted to root mean square (RMS) voltage before the analog-to-digital converter (ADC). • Vrms = Vp / sqrt(2) Schematic of test circuit

  6. Progress Results To Date • Currently testing EMG sensor (Advancer Tech) with 3.3V Arduino Pro Micro • EMG signal proved inaccurate and very slow to change to movement of subject • EMG sensor was expensive ($50)

  7. Mismatch of MCU input between the signal voltage and current • Created a current divider and voltage divider to solve this

  8. Discussion From the last presentation • Subject’s body perspirationaffects measurements • Material should be waterproof, need a thermoplastic material • Band location on subject varies • More testing to identify best location

  9. Conclusion ; Next Step • Got software test for EMG prototype fine tuned • Identified good potential mcu to use for production prototype (arm-based cortex) and vendor • Battery life (need one week usage) • Noise interference