An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MicroMaster serie 4 frequentieregelaars The next generation • MicroMaster 440 (Micromaster Vector) Vermogen 0,12-200 kW • MicroMaster 430(Micromaster Eco)Vermogen 7,5 - 90 kW(VT) • MicroMaster 420 (MicromasterBasic) Vermogen 0,12- 11 kW • MicroMaster 410 (MicromasterJunior) • Vermogen 0,12– 0,75 kW

  2. MicroMaster 410 De prijsbewuste • Vermogensbereik 120W tot 750W • Netspanning 115V of 230V één-fase • Uitgangspanning 230V drie-fase • Intern klasse B filter • Prijsgunstig • Wandbevestiging, ook zijwaarts of DIN rail optie. • Parameters gelijkaan MICROMASTER 420 en 440 • Parametrering d.m.v. paneel of software • Geen Ventilator • Ook met coldplate voor 0.37 &0,75kW

  3. Micromaster 420 De Universele • Vermogen tot 0,12 t/m 11 kW (CT) • U/f en FCCregelprincipe. • Ingebouwd EMC filter verkrijgbaar. • 3 Digitaal in, 1 Analoog in, 1 Relais uit & 1 Analoog uitgang. • Overbelastingscapaciteit :150% voor 60 seconden om de 5 minuten. • Geïntegreerde PI regeling. • Spanningsbereik 1AC/200 - 3AC/480 Volt • DC gelijkstroom- en compound remmen • Bedrijfstemperatuur -10°C tot 50°C • Lage aardlekstroom tot 9 mA met filter tot 3,5 mA. • Flexibele I/O koppeling met parameters d.m.v. BiCo - technologie • Uniforme parametersetting • CE, UL, CUL gecertificeerd • beschermingsklasse IP20/NEMA 1

  4. Micromaster 430De Pompen & ventilatoren specialist • Vermogens range 7,5 kW- 250kW bij quadratisch belastingskoppel • Netspanning 380 V - 480 V 3fase • U/f-regeling & FCC • Hand/Auto-Bedrijf • Software aplicaties: • Droogloop detectie • motorstaging • Energy saving mode. • 6 Digitale en 2 Analoge Ingangen • 3 Relais en 2 Analoge uitgangen • PID-Regeling (Autotuning) • PTC aansluiting. • Flexibele I/O koppeling d.m.v. BiCo - technologie • CE, UL, CUL en c-tick • beschermingsklasse IP20/NEMA 1 • geintregeert/ onderbouw filter (A/ B)

  5. MicroMaster 440 De alleskunner • Vermogensbereik 0,12 - 200 kW • Spanningsbereik (1AC/200-3AC/600Volt) • 3 Drivedata& 3 Commanddata settings • Vector Control (encoder optioneel) • Torque Control (koppel als setpoint) • 6 Digitaal & 2 Analoog in, 3 relais & 2 Analoog uit • Geïntegreerde remchopper tm75kW • Overbelasting:200% Inom voor 3s, 150% voor 60s om de 5 minuten • Geïntegreerde PID regeling • Logische bouwstenen:3AND, 3OR, 3X0R, 3NOR, 4Timer, 4x teller • Kinetische buffering • I/O data instelbaar dmv BiCo - technologie • Uniforme parametersetting • CE, UL, CUL gecertificeerd • beschermingsklasse IP20/NEMA 1 • DC gelijkstroom- en compound remmen

  6. Basic operator panel BOP Profibus …... AOP Advanced operator panel CAN open Communicatie Opties PC interface DeviceNet RS232 Encoder option (MM440) • 6 digital in • 2 analogue in • PTC input • 3 relay out • 2 Analog out • USS (RS485) I/O Board Encoder Optie Micromaster 4 interface concept

  7. MICROMASTER 440 3 x Drive Data & Drive Command setting • Bijv: P0304(= motor spanning) kan 3 waarden bevatten, waartussen geschakeld kan worden. DriveDataSetting • Bijv: P0700(=selectie van sturingsbron) kan onafhankelijk van DDS geschakeld worden tussen 3 waarden. CommandDataSetting

  8. MICROMASTER 4 - BiCo-techniek P840 Aan/uit 1 commando 24V r0722 P0840 722.0 Status binaire ingangen 5V Bron= ingang 1 (bit 0 van r722) Binaire ingang BI: 1. OFF2 P0844 1:0 BI: 2. OFF2 P0815 1:0 P1000 = 7 oder P1070 = 755.1 CI: Main setpoint P1070 755.1 Drive kernal CO: Act ADC after scal. [4000h] r0755[0] Analog input CO: Act. ADC after scal. [4000h] r0755[1] ADC P0771[0] = 26 CI: DAC P0771 [0] (26) CO: Act. DC-link voltage Analog output r0026 CI: DAC P0771 [1] (21) P0771[1] = 21 DAC CO: Act. frequency r0021 P0701 = 99 en P0840 = 722.0 of: P0700 = 2 en P0701 = 1