Agenda • Insulation • Product Applications • Floors • Walls • Roofs
RigidPhenolic Insulation RigidUrethaneInsulation ExtrudedPolystyreneInsulation RockMineralFibre GlassMineralFibre Cork ExpandedPolystyrene Aged Thermal Conductivity
Thickness of rigid urethane P/A 0.43 P/A 0.29 60 mm 0.24 0.22 70 mm 0.22 0.20 75 mm 0.21 0.19 90 mm 0.18 0.17 100 mm 0.17 0.16 Floor U-values (W/m2k Assumes a 14 x 7 m and a 14 x 14 m solid concrete or beam and dense block floor. P/A of 0.43 and 0.29 respectively
Thicknesses (mm) to Achieve a U-value of 0.25 W/m2.K Thicknesses (mm) to Achieve a U-value of 0.20 W/m2.K Soffit Lining K10 80 K10 100 Assumes concrete deck with direct fix
U-values achieved W/m2.K Medium Density Block Aircrete 7N U-values achieved W/m2.K Aircrete 3.5N Aircrete 2.8N Masonry Cavity Wall Construction Kooltherm K8 - 50mm 0.27 0.25 Kooltherm K8 – 50mm 0.24 0.23 Assumes 12.5 mm plasterboard on dabs lining a block inner leaf and brick outer leaf
External Wall Construction Steel Frame Wall
Thicknesses (mm) to Achieve a U-value of 0.25 W/m2.K Thicknesses (mm) to Achieve a U-value of 0.22 W/m2.K Steel Frame Wall / brickwork Kooltherm K12 60 Kooltherm K12, with fibre between studs 60 Assumes warm wall construction
External Wall Construction Timber Frame Wall
External Wall Applications Kingspan Kooltherm K-range: Applications Rainscreen External Render
Thicknesses (mm) to Achieve a U-value of 0.35 W/m2.K K15 55 Thicknesses (mm) to Achieve a U-value of 0.27 W/m2.K K15 + metal studs filled with fibre 80 Steel Frame Wall / Rainscreen * Conventions on U-value calculations
Thicknesses (mm) to Achieve a U-value of 0.35 W/m2.K K5EWB 50 Thicknesses (mm) to Achieve a U-value of 0.26 W/m2.K K5EWB 70 Masonry with external wall insulation (EWI)
No Ventilation Ventilation Warm storage Cold loft - not advisable for storage Pitched Roof Construction Cold Roof Warm Roof Partially insulated leavingventilated spaces Fully insulated - no ventilation
Pitched Roof Construction - Warm Roof Unventilated insulation between& over rafters Unventilated insulation over rafters 100 mm Kooltherm K7 over rafters to achieve a U-value of 0.20 W/m2.K 50 mm Kooltherm K7 between & 60 over rafters to achieve a U-value of 0.20 W/m2.K
Pitched Cold Roof Ventilated with insulation between and below rafters Ventilated with insulation between rafters 100mm Kooltherm K7 between rafters and 37.5mm Kooltherm K18 underneath the rafters to achieve 0.2 W/m2K 75mm Kooltherm K7 between rafters to achieve 0.35 W/m2K
Thickness requirements for new build *Assuming profiled metal deck, polythene VCL, Kingspan Thermaroof TR26 LPC/FM, single ply membrane (mechanically fixed using tubular fasteners), (No internal finishes).
Tapered Roofing Systems The build-up concept . . . . . . . . tapers the insulation, rather than the screed or the structural deck, to overcome water ponding