1 / 19

630 A

NZM-XMC Measuring- and Communication Module. TC. DISP. 500 A . 250 A . 630 A. Saving Energy - Motivation. Building. Production. Logistics. ISO 50001. Save money. Improve Company image. Save tax. ISO 50001 - Standardisation Support for Energy Efficieny .

yosef
Download Presentation

630 A

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NZM-XMC Measuring- and Communication Module TC DISP 500 A 250 A 630 A

  2. SavingEnergy - Motivation Building Production Logistics ISO 50001 Save money Improve Company image Save tax

  3. ISO 50001 - Standardisation Support for Energy Efficieny DIN EN ISO 50001:2011-12 Requirements on energy management systems Verification of processes for energy optimization Certificate (DQS) e.g. Germany: >1GWh consumption >10GWh (Erneuerbare-Energiengesetz) Improve company image Energy costs >14% of added value Save taxes and fees

  4. Measuring and Analysis is the foundation Process of ISO 50001 EATON providesinnovationbynewmeasuring- andloggingsystems

  5. Innovation by XMC andBreakerVisu Measuring Innovation • XMC • Measuring System • Simplifies wiring Analyses Innovation • BreakerVisu • Visualisation- and Loggingsystem • Energydata direct to Excel

  6. XMC: The Concept classic compact + basic setup + easy to install + attractive price + all-purpose - high amount of wiring

  7. XMC: The Principal Incorporated CTs Remote Control Display 2 dig. Q 2 dig. I Modbus XMC Dig S0 output Voltage access

  8. Metering Data of MB Version Data via Modbus and Display accessible: Phase voltages L-N und L-L Phase currents L1,L2,L3Active power per phase and directionActive power totalReactive energy per phaseReactive energy totalReactive energy capacitive/inductiveApparent power per phaseApparent power totalPower factor (Cos Phi)FrequencyMax. Demand6 configurable alarms

  9. Basics on Power • Active power [Watt] • P=u*icos phi • Real power (billing) • Reactive Power [var] • Q=u*i sin phi • Unwanted, unusable power; bouncing between generator and consumer • Apparent Power [VA] • S=U*I • Needed for defining wiring and transformer dimension G M G M

  10. Device versions -S0 (Standard Version)-MB (Modbus Version) Display interface 1 dig S0 Pulse-Outputfor Active Energy Fieldbus interface (Modbus) 2 S0 Pulse-Outputsfor Active Energy Expandable with max 2 cards: Ideal to incorporate energy data via SmartWireDarwin

  11. S0-pulse output Typical signal according EN 62053-31 requirements

  12. The NZM-XMC-TC-MB Module XMC: Measuring and Communication Module for NZM a new member in the family: NZM-XMC-TC-MB Transducer

  13. XMC-TC Features and Benefits • Features: • Classical external CTs and voltage wiring • Current Range 32A to 1600A • ModbusRTU Interface • Compatible data set to XMC • Energy Pulse Output S0 • Alarm output NZM-XMC-TC XMC-TC XMC-TC NZM2-XMC NZM3-XMC NZM 1 NZM 2 NZM 3 NZM 4 300A 160A 630A 1600A • Benefits: • Widens the application to entire range of NZM • Any CTs can be used (Retrofit) • Extreme narrow installation becomes feasible • Already supported by actual BreakerVisu

  14. Assortment

  15. Configuration XMC_Config_Tool

  16. Topology for other Networks Gateway to PROFINET or PROFIBUS-DP Scada M S Metering BusModbus RTU PROFIBUS-DP or PROFINET or Ethernet PLC M S

  17. Technical Data • Voltage Measuring • Range: 40...690 V • Error: 0.49% reading + 0.01%FS • Current Measuring • Range: 115% ... 1% Ir • 300A: 350...3A • 630A: 735...6.3A • Error: 0.49% reading + 0.01% FS • Power / Energy • Error: 0.99% reading + 0.01% FS

  18. Available Sales Tools Flyer: Capture Energy by Crcuit Breaker Communication SAP:168546 GB FTP Server: ftp://ftp.moeller.net/CIRCUIT_BREAKER/KOMMUNIKATION/XMC_Measuring/ XMC_Config_tool Program Samples Support: Rainer Menden Phone:-492286022334 E-Mail:rainermenden@eaton.com Daniel Jansen Phone: -492286022260 E-Mail:danieljansen@eaton.com