Electrical Safety. Responsibilities Hazard Control Electrical Equipment Personal Protective Equipment. Responsibilities. Management Training Safety Corrective action Meets code and regulations Employees Report deficiencies immediately
E N D
Electrical Safety Responsibilities Hazard Control Electrical Equipment Personal Protective Equipment
Responsibilities • Management • Training • Safety • Corrective action • Meets code and regulations • Employees • Report deficiencies immediately • Only perform work on equipment authorized / trained for • Properly inspect all electrical equipment prior to use
Hazard Control • Engineering Controls • Electrical panels, breakers, disconnects, etc… are enclosed • When required - water tight enclosures are in use • Electrical distribution areas are properly grounded • Clear approach of 36”side and front is maintained • Conduit is fully supported • All non-rigid cords have strain relief where necessary • Administrative Controls • Only trained & authorized employees conduct electrical repairs • Barriers & warning signs - prevent unauthorized entry • Lockout / tagout • Electrical control devices properly labeled
Electrical Equipment • Examination - free from recognized hazards • suitability of equipment for an identified purpose • mechanical strength and durability • electrical insulation • heating effects under conditions of use • arcing effects • classification by type, size, voltage,current capacity & use • safeguarding of employees using or coming into contact with equipment • Identification of Disconnecting Means & Circuits • shall be legibly marked to indicate its purpose • at the point where the circuit originates • each service, feeder, and branch circuit
Personal Protective Equipment • Shall be used when contact with exposed electrical sources are likely • Shall be designed for the job and environment • Shall be inspected or tested before use • Non-conductive head PPE required where overhead or energized parts exist. • Eye / face PPE required when electrical arcs, flashes or flying objects exist. • Shall maintain insulating capabilities at all times. • Electrically rated safety shoes / boots / gloves / head gear • Tools properly insulated • Electrically rated matting for all distribution panels / utility rooms
PPE Continued • Fuse handling equipment insulated for the circuit voltage • Ropes and other hand lines • Portable ladders shall have non-conductive side rails • Working on elevated platform - REQUIRES - safety watch on the ground • Personnel working in elevated platforms must wear safety harness and lanyard • Lockout tagout • Locks attached to prevent operating the disconnecting source • Tag contain a statement prohibiting unauthorized operation • Warning signs and barricades and or a safety attendant
Standard Operating Procedures Electrical Pre-work Procedures • Treat all electrical circuits as “Live” • Obtain permission from supervisor • Lockout / tagout at electrical power sources • Verify de-energized conditions exist - operate controls • Voltmeter verification at live electrical source - must be rated for voltage • Check exposed circuits phase to ground • No voltage in exposed circuits - it’s ok to work • If voltage is detected - Stop - determine source & eliminate voltage • Conduct work • Close up exposed circuits, boxes, control panels and equipment • Remove lock and tag • Obtain supervisor permission to energize circuits
Standard Operating ProceduresWorking on Exposed Energized Circuits • Obtain permission from manager • Lock out and tag out all circuits possible • Treat all circuits as energized • Remove all conductive clothing and jewelry • Use all required PPE - including shields & barriers • Inspect all overhead lines before starting • Provide adequate lighting • Don’t reach were you cant see • Approach distance see chart next slide.
APPROACH DISTANCE FOR QUALIFIED EMPLOYEES ALTERNATING CURRENT Voltage range (phase to phase)Minimum approach distance 300V and less……………………………. Avoid Contact Over 300V, not over 750V……………. 1 ft. 0 in. ( 30.5 cm) Over 750V, not over 2kV……………… 1 ft. 6 in. ( 46 cm) Over 2kV, not over 15kV……………. 2 ft. 0 in. ( 61 cm) Over 15kV, not over 37kV……………. 3 ft. 0 in. ( 91 cm) Over 37kV, not over 87.5 kV…………. 3 ft. 6 in. (107 cm) Over 87.5kV, not over 121kV………… 4 ft. 0 in. (122 cm) Over 121kv, not over 140kV…………… 4 ft. 6 in. (137 cm) • Employees entering a confined space with exposed energized parts, must use protective barriers, shields, or insulated materials rated at or above the present voltage. • Secure all doors to prevent contact with employee and causing employee contact with energized parts
Re-energizing Electrical Circuits After Work is Completed • Qualified person shall • conduct test and visual inspection • verify all tools / equipment have been removed • Warn all employees that the system is going to be re-energized • Remove all locks and tags (by the individual that installed them) • Conduct a visual determine that all employees are clear and energize the system
Powered Equipment Safety Rules • PEE = Cord or plug-type electrical devices including extension cords • damage free - no stapling, nailing or door jams • visually inspected - if damage is present repair immediately • do not over load circuits • ground type plugs - to - ground type receptacles • never alter plugs • if moisture is present - equipment must be double insulated or rated for the job • it’s not a good idea to be standing in water while operating PPE • locking-type connectors shall be properly secured when connected to a
Electrical Circuits Safety Procedures • Electrical power and light circuits are devices designed to connect or reverse circuits under a power load condition • cable connectors, (not load-breakers) fuses, terminal plugs or cable splice connectors may not be used, unless an emergency, to connect, disconnect or reverse in place of proper electrical circuits • once a protective circuit is disconnected or opened, it may not be connected or closed until it is determined safe to energize • over current protectors or circuits or connected circuits are never modified • only qualified employees may perform electrical circuit or equipment tests • all test equipment must be inspected before use - if damaged remove from service • test equipment must meet or exceed the voltage being tested & environment • electrical equipment is may not be used around flammable material unless the proper measures have been taken to prevent the hazardous condition from developing