SPS MEASUREMENTS WITH IPMs IN 2007. J. Koopman and E. Métral. SFTPRO1 LHC 25 ns (without and with controlled transverse blow-up for ecloud studies) IONS 1 bunch on the long injection flat bottom 4 bunches up to 450 GeV/c 3 bunches up to 270 GeV/c Conclusions and outlook.
E N D
SPS MEASUREMENTS WITH IPMs IN 2007 J. Koopman and E. Métral • SFTPRO1 • LHC 25 ns (without and with controlled transverse blow-up for ecloud studies) • IONS • 1 bunch on the long injection flat bottom • 4 bunches up to 450 GeV/c • 3 bunches up to 270 GeV/c • Conclusions and outlook
SFTPRO1 (07/11/07) Gaussian of constant normalized emittance in blue x = 3.56 mm BIPMH51634 x = 87.9 m x = 0.81 mm
LHC 25 ns (08/11/07) WITHOUT controlled BU WITH controlled BU (ecloud studies) Gaussian of constant normalized emittance in blue x = 2.68 mm x = 1.51 mm x = 2.10 mm
IONS: 1 bunch on the long injection flat bottom (30/10/07) BIPMV51734 y = 91.2 m y 2.7 mm Comparison with BWS meas.: ~ 0.55 m Good agreement!
IONS: 4 bunches up to 450 GeV/c (30/10/07) y = 3.2 mm y = 1.3 mm Comparison with BWS meas.: After 1st inj. 0.55 m 12800 ms 0.83 m ~ 4 times bigger value at 450 GeV/c with IPMV!
IONS: 3 bunches up to 270 GeV/c (24/10/07) After 2nd inj After 1st inj y = 2.99 mm y = 3.00 mm After 3rd inj y = 3.25 mm y = 1.28 mm ~ 2.5 times bigger value at 270 GeV/c with IPMV!
CONCLUSIONS AND OUTLOOK (1/2) • Measurements have been performed in 2007 with both IPMH and IPMV (not working at the same time!) • Good agreement found with BWS at low energy • However, (with the ions) at top energy bigger values were measured with the IPMs wrt the BWS • At 270 GeV/c A factor of ~ 2.5 • At 450 GeV/c A factor of ~ 4 • Another issue which has to be understood is the value of the signal after multiple injections
CONCLUSIONS AND OUTLOOK (2/2) • Next year a detailed comparison between the IPMs and the BWS should be made The IPM is really a nice tool to observe “online” any blow-up of the transverse emittance (or modification of the profile) at any time along the cycle WITH controlled BU (ecloud studies) Gaussian of constant normalized emittance in blue