Protein Purification by Ion Exchange Chromatography

Protein Purification by Ion Exchange Chromatography. Column Chromatography. Ion Exchange Chromatography. Uses a solid matrix with either a positive or negative charge Separation is based on an equilibrium of the molecules adsorbed to the exchanger versus the elution solvent

ziva
Download Presentation

Protein Purification by Ion Exchange Chromatography

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Protein Purification by Ion Exchange Chromatography

  2. Column Chromatography

  3. Ion Exchange Chromatography • Uses a solid matrix with either a positive or negative charge • Separation is based on an equilibrium of the molecules adsorbed to the exchanger versus the elution solvent • Changing the ionic strength or pH of the solvent allows separation of molecules with small differences in charge

  4. Two Types of Ion Exchangers • A cation exchanger • Bead is negative and adsorbs positively charged molecules • An anion exchanger • Bead is positive and adsorbs negatively charged molecules

  5. If You Are Purifying a Positively Charged Molecule… • Which type of ion exchanger would you use? • Cationic • Anionic • What would be the charge on the matrix? • Positive • Negative

  6. Basis for Our Ion Exchange Experiment + + - - - + - + + - - + + - + + + Sample: negatively charged protein + + + + + Beads have a positive charge

  7. - - - - - - - Basis for Our Ion Exchange Experiment + + + + + + + + + + Sample: negatively charged protein + + + + Beads have a positive charge How can you remove the sample from the bead?

  8. KOAc - - +- - - - - - - - Basis for Our Ion Exchange Experiment Add a salt solution (potassium acetate) Negatively-charged acetate competes for bead - + + - + - + + + + + + + Sample:Negatively charged protein + + + + Eluant: fluid/sample that is removed from column

  9. Our Ion Exchange Experiment + - - - + + - + + + + - - + + - + + + + + Mixed Sample Negatively charged protein: GFPPositively charged protein: Cytochrome C + + + + + + + Beads have a positive charge GFP= Green Fluorescent Protein, from jellyfish, used to follow gene expression Cytochrome C= protein involved in electron transport chain

  10. - + + - + - + - - + + - - + Our Ion Exchange Experiment + + + + + + + + + + Mixed Sample + + + +

  11. Add 0.01 M KOAc - - - - - + + + + + Our Ion Exchange Experiment + - + + - + - + + - + + - + + + + Mixed Sample + - - + + + Cytochrome Celutes from column

  12. Add 0.5 M KOAc - - - - - - - - - - - - - - - - - - - Our Ion Exchange Experiment + + + - + - + + + + + + + + Mixed Sample + + + + GFP elutes from column

  13. Guide for Today’s Lab • Control flow of eluant by removing or replacing the cap on the column • Follow directions on pages 79 for • Packing the column • Separating the sample • Green Fluorescent Protein is negatively charged • Cytochrome C (yellow) is positively charged • Quantifying the sample

  14. Guide for Today’s Lab • Follow directions on page 7 for • Packing the column (Do ALL steps listed in lab manual, only some are summarized here) • Attach column to ring stand (step 1) • Rinse with 0.01M KOAc (step 3) • Pour slurry into column (step 5) • Wash column with additional 0.01M KOAc (steps 6 & 7) DO NOT LET THE COLUMN RUN DRY

  15. Prepare anion exchanger column

  16. Guide for Today’s Lab • Follow directions on pages 78 for • Separating the sample • Add sample to top of column bed (steps 1 & 2) • Using 0.01 M KOAc, collect 1 ml fractions until cytochrome C (red dye) has completely eluted (steps 3-5) • Allow remaining 0.01 M KOAc to leave reservoir (step 6) • Using 0.5 M KOAc, collect 1 ml fractions until Green Fluorescent Protein (blue-green dye) has completely eluted (steps 7-10) • Measure the eluted volumes for GFP (step 11)

  17. Guide for Today’s Lab • Follow directions on pages 89 for • Quantifying the sample • Prepare a standard curve for GFP (blue-green dye) (step 1), reading A550 for dilutions from the stock solution (step 1) • Determine the A550 value for each of the fractions containing GFP (step 2) NOTE: 5 ml samples are required for the spectrophotometer readings. You may either 1. Dilute your fractions at least 1:5 for analysis and then multiply by the dilution factor before extrapolating from the standard curve OR 2. Combine your fractions into one tube, add water if necessary to reach 5 ml and read A550. Correct for the volume when calculating the amount of GFP recovered.

  18. Read A550THEN Use for next dilution Read A550THEN Use for next dilution H2O H2O 3 ml 3 ml 1 mg/ml 0.5 mg/ml 3 ml 3 ml Dilutions for Standard CurvePage 8 6 ml stock 1 mg/ml 0.5 mg/ml 0.25 mg/ml

  19. Spectrophotometer Operation Set wavelengthto 550 nm Empty Pure water 100% transmittance Zero transmittance Calibration Read standards and samples at 550 nm