Processor Board

Two and Three Electrode Potentiostats. Three-Electrode Design. Sponsored By. Background Information Dr. Harnett’s lab needs up to 15 potentiostats that are: Inexpensive (less than $100 per unit) Easy to assemble by students OTS solutions range from $5K to $10K Theory of Use

zorina
Download Presentation

Processor Board

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Two and Three Electrode Potentiostats Three-Electrode Design Sponsored By • Background Information • Dr. Harnett’s lab needs up to 15 potentiostats that are: • Inexpensive (less than $100 per unit) • Easy to assemble by students • OTS solutions range from $5K to $10K • Theory of Use • A potentiostat is: • The electronic hardware required to control a three electrode cell and run most electro-analytical experiments • An electronic instrument that controls the voltage difference between a Working Electrode and a Reference Electrode. • It measures the current flow between the Working and Counter Electrodes. • Design Methods • Two-Electrode Potentiostat • Previously developed by Capstone group during Fall 2010 • Follow-on project by Ben Williams • Firmware improvements • Hardware component revision • Three-Electrode Potentiostat • Originally developed by University of California Santa Barbara Cindy Harnett Group Members: Kyle Bloomer, Luke Bennett, Josh Geiman • Experiment • Tested the current difference in four orange juice samples caused by varying amounts of ascorbic acid • 0, 0.1, 0.2, and 0.3M of ascorbic acid in each sample, respectively • Electrode usage • Counter: Platinum wire • Working: Pencil “lead” • Reference: Standard Ag/AgCl DDMS Processor Board Two-Electrode Results Three-Electrode Results Expected Results Two-Electrode Design Arduino Development Board Daughter Card • Conclusions and Recommendations • Results gathered from experiment do not coincide with expected results. • Possible contributing factors: • Reference electrode in poor condition • Possible firmware issues with measurement execution • Possible errors in chemistry related procedures DDMS • Objectives • Improve existing Two-Electrode Potentiostat • Implement Three-Electrode Potentiostat • Test and compare results between designs

More Related