1 / 2

UT351 Demonstration Outline

UT351 Demonstration Outline. Successful Actions of a Sales Call. Preparation Connect Power Terminals 8,9 & 10 Connect Loop Simulator – 4859SIM - $15.00 Yellow – 12, Red – 13, White – 16, Black – 17 Power on unit If display reads “In” and “OFF”, Power off and begin demo.

zubin
Download Presentation

UT351 Demonstration Outline

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UT351 Demonstration Outline Successful Actions of a Sales Call • Preparation • Connect Power • Terminals 8,9 & 10 • Connect Loop Simulator – 4859SIM - $15.00 • Yellow – 12, Red – 13, White – 16, Black – 17 • Power on unit • If display reads “In” and “OFF”, Power off and begin demo. • Set IN Parameter to “OFF” • Hold Set Key for 3 Seconds • Press arrow key to StUP, press enter twice • Press arrow key to I/O, Press enter. • Change In to off, enter. • Power off and begin demo. • Begin Demo • Physical Demonstration • Show Display • Large LEDs • Simple key configuration • LED status indicators • Explain IP55 face, dust proof, wash down rating • LL100 interface port – Talk a bit about LL100 but show later. • Show data plate • Terminal wiring layout • Model & suffix code • Approvals • Show rear terminal block • Terminal arrangement, terminal numbers stamped on case. • Washers integrated into screws, no need for spade lugs • Explain Universal inputs, outputs and power • Digital Inputs • Alarm Outputs • Retransmission – 15VDC LPS • Optional Communications • RJ45 Jack for Ethernet Preliminaries: The warming up events at the start of the call • Investigating: • Finding out the facts, application information, and customer needs/requirements • What is your application? • What are your controller requirements? Successful sellers put their efforts here Demonstrating Capability: Showing that you have something worthwhile to offer Obtaining Commitment: Gaining an agreement to proceed to a further stage of the sale UT351 Demo Guide

  2. UT351 Demonstration Outline • Set - Up Demonstration • Power up instrument • Explain initial power up screen for simple setup. • Explain short form manuals. • Show the following in the Parameters short form manual • Input range codes table – Set “IN” using this. • Alarm types table • Parameter Setting display (Parameter map) • Set “IN” to 1 & Units to deg F • Scroll through menu briefly talk about units, range setting, RJC & OT. • Set OT = 2 for 4 – 20 ma output. • Exit to main menu – explain that setup for 75% of applications is complete • Show operating display • Scroll between SP and OUT display • A/M key – manual output adjust • Change setpoint to 500 – explain incrementing display speed • Auto Tune • Go to Auto tune parameter, set to “1” • Explain how auto tune bumps process 3 times while tuning occurs • Output changes from 0% to 100% • Process dynamics are observed and PID values are automatically set in controller • Ziegler – Nichols Method used to calculate PID • For more info - “Controller Tuning and Control Loop Performance” by David W. St. Clair • http://members.aol.com/pidcontrol/ to purchase • Increase setpoint 50 deg. and observe overshoot • Explain this is normal PID operation for any controller on the market. • Change setpoint back to 500 deg. • Super Control • Go to SC parameter, set to “1” for overshoot suppression • Explain expert operator • Fuzzy Logic • Setpoint modifier • Learns process • Increase setpoint 50 deg and observe overshoot • Emphasize effect of super control • Set it and forget it • Software Preparation • Ethernet Setup • Set up PC to talk to local IP address • Configure controller to IP address • IP:192.168.1.xxx • Subnet 255.255.255.0 • DG: 0.0.0.0 • ESW 1 • Launch LL100 or LL200 • Software Demo • Explain software tools • Custom Computation Building tool • UT750 & UP750 only • Parameter setting tool • Program pattern setting tool • UP550 & UP750 only • Upload Data from the controller • For Ethernet, set correct address! • Show parameter menus – Explain common parameters applicable to the application • Input/Output parameter setting • Input Type • Output Type • Setup parameters • Alarm Settings • Active color Modes – set to “6” • Zone PID selection • Retransmission Parameters • Digital input selection • Custom select parameters set auto tune parameter • Ethernet • Operating parameter • Alarms • Super Control • Filter and bias • Setpoint Ramps • Output Limits • Active color high and low limits • PID • Show File Information screen • Data is not stored in controller • Save file • Download to controller • Show Tuning screen • Change update time to 1 second • Explain data is instantaneous and not for data acquisition • Change controller modes • Change PID to 5, 240, 60 • Change SP • Wait until controller reaches SP • Run auto tune • Questions? UT351 Demo Guide

More Related