An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. STRUCTURAL DYNAMICS IN BULDING CODES

  2. BUILDING CODES : ANALYSES • STATIC ANALYSIS • Structures be designed to resist specified static lateral forces related to the properties of the structure and seismicity of the region. • Formulas based on an estimated natural period of vibration are specified for base shear and distribution of lateral forces over the height of the building. • Static analysis provides the design forces including shears and overturning moments for various stories. • DYNAMIC ANALYSES • RESPONSE SPECTRUM ANALYSIS • RESPONSE HISTORY ANALYSIS • .

  3. International Building Code - USABase Shear Vb = csw where Cs = Ce &Ce= IC R Cs corresponding to R = 1 is called the elastic seismic coefficientW= total dead load and applicable portions of other loads R = 1.0 I = 1.0, 1.25 or 1.5 C depends on the location of structure and the site classes defined in the code accounting for local soil effects on ground motion. C is also related to pseudo-acceleration design spectrum values at short periods and and at T = 1 second.

  4. International Building Code - USALATERAL FORCES Fj = Vb wjhkj ∑ni=1wihik Where K is a coefficient related to the vibration period .

  5. International Building Code - USAStory Forces The design values of story shears are determined by static analysis of the structure subjected to the lateral forces; the effects of gravity and other loads should be included. Similarly determined overturning moments are multiplied by a reduction factor J defined as follows: J = 1.0 for top 10 stories; between 1.0 and 0.8 for the next 10 stories from the top; varying linearly with height; 0.8 for remaining stories.

  6. National Building Code of CanadaBase Shear Vb = csw where Cs = Ce U & Ce = vSIF R U= 0.6 Calibration Factor zonal velocity v = 0 to 0.4 Seismic importance factor I = 1.5, 1.3, 1.0 Foundation factor F = 1.0, 1.3, 1.5, or 2.0 Seismic response factor S varies with fundamental natural vibration period of the building. Canada is divided in 7 velocity and acceleration related seismic zones

  7. National Building Code of CanadaLATERAL FORCE Fj = (Vb-Ft) wjhj ∑ni=1wihi with the exception that force at the top floor is increased by an additional force , the top force, Ft .

  8. National Building Code of CanadaSTORY FORCES The design value of story shears are determined by static analysis of the structure subjected to these lateral forces. Similarly determined overturning moments are multiplied by reduction factors J and Ji at the base and at the i th floor level.

  9. EuroCode 8Base Shear Vb = csw where Cs = Ce / q’ Ce = A/g = A/g {(Tb/ TI)-1/3} q’ = 1+(T1 / Tb) (q-1) = q Seismic behavior factor q varies between 1.5 and 8 depending on various factors including structural materials and structural system.

  10. EuroCode 8LATERAL FORCES Fj = Vbwj Φj1 ∑ni=1wi ΦJ1 where Φj1 is the displacement of the jth floor in the fundamental mode of vibration. The code permits linear approximation of the this mode which becomes: Fj = Vb wjhj ∑ni=1wihi

  11. EuroCode 8STORY FORCES The design values of story shears, story overturning moments, and element forces are determined by static analysis of the building subjected to these lateral forces; the computed moments are not multiplied by a reduction factor.

  12. Fundamental Vibration Period Period formulae used in IBC, NBCC and others codes are derived out of Rayleigh’s method using the shape function given by the static deflection, Ui due to a set of lateral forces Fi at the floor levels.

  13. Elastic seismic coefficient • Elastic seismic coefficient Ce is related to the pseudo – acceleration spectrum for linearly elastic systems. • The Ce and A/g as specified in codes are not identical. • The ratio of Cc  A/g is plotted as a function of period and it exceeds unity for most periods.

  14. CONCLUSION • There can be major design deficiencies, if the building code is applied to structures whose dynamic properties differ significantly from these of ordinary buildings. • Building codes should not be applied to special structures, such as high-rise buildings, dams, nuclear power plants, offshore oil- drilling platforms, long spane bridges etc.

  15. Requirement of RC Design • Sufficiently stiff against lateral displacement. • Strength to resist inertial forces imposed by the ground motion. • Detailing be adequate for response in nonlinear range under displacement reversals.

  16. Design Process • Pre-dimensioning • Analysis. • Review. • Detailing. • Production of structural drawings. • Final Review.

  17. Requirement for structural Response • Stiffness • Stiffness defines the dynamic characteristics of the structure as in fundamental mode and vibration modes. • Global and individual members stiffness affects other aspects of the response including non participating structural elements behavior, nonstructural elements damage, and global stability of the structure. Contd

  18. STRENGTH • The structure as a whole, its elements and cross sections within the elements must have appropriate strength to resist the gravity effects along with the forces associated with the response to the inertial effects caused by the earthquake ground motion.

  19. Toughness • The term toughness describes the ability of the reinforced concrete structure to sustain excursions in the non linear ranges of response without critical decrease of strength.

  20. Seismic Design Categories • Category A: Ordinary moment resisting frames. • Category B. • Ordinary moment resisting frames. • Flexural members have two continuous longitudinal bars at top & bottom • Columns having slenderness ratio of 5 or less • Shear design must be made for a factored shear twice that obtained from analysis.

  21. Category C. • Intermediate moment frames. • Chapter 21 of ACI 318 implemented. • Shear walls designed like a normal wall. • Category D, E and F. • Special moment frames • Special reinforced concrete walls.

  22. Earth quake Design Ground Motion Earth quake Design ground Motion • Maximum Considered Earthquake and • Design Ground Motion • For most regions, the minimum considered earthquake ground motion is defined with a uniform likelihood of excudance of 2% in 50 years (approximate return period of 2500 years). • In regions of high seismicity, it is considered more appropriate to determine directly maximum considered earthquake ground motion base on the characteristic earthquakes of these defined faults multiplied by 1.5.

  23. Site Classification • Where Vs = average shear wave velocity. N = average standard penetration - resistance. Nch = average standard penetration - resistance for cohesiveless soils. Su = average un-drianed shear strength in cohesive soil.

  24. All ordinates of this site specific response spectrum must be greater or aqual to 80% of the spectural value of the response spectra obtained from the umpped values of Ss and Si, as shown on previous slide. • Use Groups. As per SEI/ASCE 7-02.

  25. Required Seismic Design Category • The structure must be assigned to the most severe seismic design category obtained from.

  26. Reinforced concrete lateral Force – Resisting Structural System

  27. Bearing Wall. Any concrete or masonry wall that supports more than 200 lbs/ft of vertical loads in addition to its own weight. • Braced Frame. An essentially vertical bent, or its equivalent of the concentric or eccentric type that is provided in a bearing walls, building frame or dual system to resist seismic forces . • Moment frame. A frame in which members and joints are capable of resisting forces by flexure as well as along the axis of the members. Contd

  28. Shear Wall. A wall bearing or non bearing designed to resist lateral seismic forces acting on the face of the wall. • Space Frame. A structural system composed of inter connected members. Other than bearing walls, which are capable of supporting vertical loads and, when designed for such an application, are capable of providing resistance to seismic forces.

  29. The approximate fundamental building period Ta is seconds is obtained Ta = C1 hxn

  30. The over turning moment at any storey MX is obtained from • MX=∑n Fi (hi– hx) • i=x

  31. Reinforced Brick Masonry • Allowable stress design provisions for reinforced masonry address failure in combined flexural and axial compression and in shear. • Stresses in masonry and reinforcement are computed using a cracked transformed section. • Allowable tensile stresses in deformed reinforcement are the specified field strength divided by a safety factor of 2.5. • Allowable flexural compressive stresses are one third the specified compressive strength of masonry.

  32. Shear stresses are computed elastically, assuming a uniform distribution of shear stress. • If allowable stresses are exceeded, all shear must be resisted by shear reinforcement and shear stresses in masonry must not exceed a second, higher set of allowable values.

  33. Seismic Design Provisions for Masonry in IBC • General. • The three basic characteristics to determine the building’s “Seismic design category” are • Building geographic location • Building function • Underlying soil characteristics • Categories A to F • Determination of Seismic Design Forces. Forces are based on • Structure Location • Underlying soil type • Degree of structural redundancy • System expected in elastic deformation capacity

  34. Seismic related Restriction on Materials • In seismic Design categories A through C, no additional seismic related restrictions apply beyond those related to design in general. • In seismic design Categories D & E, type N mortar and masonry cement are prohibited because of their relatively low tensile bond strength. • Seismic Related Restrictions on Design Methods • Seismic Design Category A. Strength design, allowable stress design or empirical design can be used.

  35. Seismic Design Category B and C elements that are part of lateral force resisting system can be designed by strength design or allowable stress design. Non-contributing elements may be designed by empirical design. • Seismic Design Category D, E and F. Elements that are part of lateral force resisting system must be designed by either strength design or allowable stress design. No empirical design be used.

  36. Seismic Related Requirement for Connectors. • Seismic Design Category A and B. No mechanical connections are required between masonry walls and roofs or floors. • Seismic Design Category C, D E and F. Connectors are required to accommodate story drift. • Seismic Related Requirements for Locations and Minimum Percentage of Reinforcement • Seismic Design Categories A and B. No restriction . • Seismic Design Category C. • In Seismic Design Categories A and B. No requirement.

  37. In Seismic Design category C, masonry partition walls must have reinforcement meeting requirements for minimum percentage and maximum spacing. Masonry walls must have reinforcement with an area of at least 0.2 sq in at corners. • In seismic design category D, masonry walls that are part of lateral force-resisting system must have uniformly distributed reinforcement in the horizontal and vertical directions with a minimum percentage of 0.0007 in each direction and a minimum summation of 0.002 (both directions). Maximum spacing in either direction is 48 in.