ACD Cavity Shapes

ACD Cavity Shapes. Rong -Li Geng Jefferson Lab ILC08, November 16-20, 2008, UIC. Low-loss (Ichiro) Shape. Many 1-cell cavities reached excellent > 45 MV/m results. ICHIRO5 (no HOM coupler) reached 36 MV/m in 2008 under KEK/JLab collaboration

Download Presentation

ACD Cavity Shapes

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ACD Cavity Shapes Rong-Li Geng Jefferson Lab ILC08, November 16-20, 2008, UIC

  2. Low-loss (Ichiro) Shape • Many 1-cell cavities reached excellent > 45 MV/m results. • ICHIRO5 (no HOM coupler) reached 36 MV/m in 2008 under KEK/JLab collaboration • New 9-cell cavities w/ improved end group design fabricated and being processed and tested at KEK ILC08, 11/16-20, 2008, UIC

  3. K. Saito et al ILC08, 11/16-20, 2008, UIC

  4. First Ichiro 9-cell test in a cryo-module T. Saeki et al., EPAC08 ILC08, 11/16-20, 2008, UIC

  5. Re-entrant Shape • Single-cell 60 mm aperture Re-entrant cavity reached record gradient 59 MV/m in 2007 under Cornell/KEK collaboration • First 9-cell re-entrant cavity 15 MV/m quench limited due to pit. Further processing and testing under way at Cornell ILC08, 11/16-20, 2008, UIC

  6. 59 MV/m single-cell Re-entrant R.L. Geng et al., PAC07 First 9-cell Re-entrant cavity by Cornell/AES H. Padamsee et al., PAC07 ILC08, 11/16-20, 2008, UIC

  7. A New ACD ShapeLow-Surface-Field (LSF) proposed by SLAC • The Low Surface Field (LSF) Design • 15% higher R/Q than TDR • 11% lower Bs/Ea  20% lower cryogenic heating • 15% lower Es/Ea than LL design, same as TDR • Field flatness 20% more sensitive to cell error than LL Z. Li and C. Adolphsen, LINAC08 ILC08, 11/16-20, 2008, UIC

  8. Opportunities and Challenges • Potential of higher gradients for shorter linac length. • Excellent single-cell results demonstrated for both low-loss/Ichiro and re-entrant shapes. • LSF shape has further improved surface field ratios. • Increased detuning challenge due to reduced mechanical strength. • Increased field flatness preservation challenge due to reduced cell-to-cell coupling. • Simulation results show acceptable emittance dilution for 60 mm aperture. Beam test is still yet to happen to fully justify. ILC08, 11/16-20, 2008, UIC