Compared dumps of LCTs from LCT x Readout (DDU) with LCT (TF).

Compared dumps of LCTs from LCT x Readout (DDU) with LCT (TF). to see if any differences due to readout results can be put into 3 categories Not that this is a brief first look at the 1 st 100 events in run 2553….more detailed analysis is in progress. Category 1: no difference * ~70%.

catori
Download Presentation

Compared dumps of LCTs from LCT x Readout (DDU) with LCT (TF).

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Compared dumps of LCTs from LCT x Readout (DDU) with LCT (TF). • to see if any differences due to readout • results can be put into 3 categories • Not that this is a brief first look at the 1st 100 events in run 2553….more detailed analysis is in progress

  2. Category 1: no difference* ~70% From TF ** L1TriggerEfficiency: processing run #2553 event #1 events so far: 2 E:1 S:1 R:2 C:31 L:0 LCT half-strip/wire group #: 36 / 21 strip pattern: 5 Strip type: 0 with quality: 6 bend: 1 and bxn: 4 E:1 S:2 R:2 C:30 L:0 LCT half-strip/wire group #: 128 / 20 strip pattern: 7 Strip type: 0 with quality: 8 bend: 1 and bxn: 3 From DDU ** L1TriggerEfficiency: processing run #2553 event #1 events so far: 2 E:1 S:1 R:2 C:31 L:0 LCT half-strip/wire group #: 36 / 21 strip pattern: 5 Strip type: 0 with quality: 6 bend: 1 and bxn: 0 E:1 S:2 R:2 C:30 L:0 LCT half-strip/wire group #: 128 / 20 strip pattern: 7 Strip type: 0 with quality: 8 bend: 1 and bxn: 1

  3. Category 2: duplicate LCTs at DDU ~26% From TF ** L1TriggerEfficiency: processing run #2553 event #4 events so far: 1 E:1 S:2 R:2 C:29 L:0 LCT half-strip/wire group #: 144 / 61 strip pattern: 7 Strip type: 0 with quality: 2 bend: 1 and bxn: 4 E:1 S:3 R:2 C:30 L:0 LCT half-strip/wire group #: 24 / 48 strip pattern: 2 Strip type: 0 with quality: 8 bend: 0 and bxn: 3 From DDU ** L1TriggerEfficiency: processing run #2553 event #4 events so far: 1 E:1 S:2 R:2 C:29 L:0 LCT half-strip/wire group #: 144 / 61 strip pattern: 7 Strip type: 0 with quality: 2 bend: 1 and bxn: 1 E:1 S:2 R:2 C:29 L:0 LCT half-strip/wire group #: 144 / 61 strip pattern: 7 Strip type: 0 with quality: 0 bend: 1 and bxn: 1 E:1 S:3 R:2 C:30 L:0 LCT half-strip/wire group #: 24 / 48 strip pattern: 2 Strip type: 0 with quality: 8 bend: 0 and bxn: 0 E:1 S:3 R:2 C:30 L:0 LCT half-strip/wire group #: 32 / 49 strip pattern: 7 Strip type: 0 with quality: 0 bend: 1 and bxn: 0 Ok, MPC filters LCTs with Q = 0

  4. Category 3: LCTs found at TF but not DDU ~3% From TF ** L1TriggerEfficiency: processing run #2553 event #14 events so far: 11 E:1 S:2 R:2 C:30 L:0 LCT half-strip/wire group #: 16 / 61 strip pattern: 2 Strip type: 1 with quality: 11 bend: 0 and bxn: 4 E:1 S:2 R:2 C:30 L:0 LCT half-strip/wire group #: 16 / 60 strip pattern: 2 Strip type: 1 with quality: 11 bend: 0 and bxn: 4 E:1 S:3 R:2 C:30 L:0 LCT half-strip/wire group #: 72 / 44 strip pattern: 2 Strip type: 0 with quality: 10 bend: 0 and bxn: 3 E:1 S:3 R:2 C:30 L:0 LCT half-strip/wire group #: 0 / 44 strip pattern: 5 Strip type: 0 with quality: 6 bend: 1 and bxn: 3 From DDU ** L1TriggerEfficiency: processing run #2553 event #14 events so far: 11 E:1 S:3 R:2 C:30 L:0 LCT half-strip/wire group #: 72 / 44 strip pattern: 2 Strip type: 0 with quality: 10 bend: 0 and bxn: 0 E:1 S:3 R:2 C:30 L:0 LCT half-strip/wire group #: 0 / 44 strip pattern: 5 Strip type: 0 with quality: 6 bend: 1 and bxn: 0

  5. Summary • Categories 1 and 2 are one in the same since MPC filters out Q=0 LCTs. • Category 3 needs further investigation. • Slava looked at the events and found that there was an ALCTs at DDU, but no CLCTs. • CLCTs being lost at readout at DDU Even though TF finds them??

  6. Other items • Greg worked with me to improve algorithm of efficiency code and add functions to clean up code • Still some work to be done…. • In ME3/2, chamber 31’s efficiencies lower than rest. Looked into these events with Slava, but found nothing conclusive….no CLCT info form DDU. Slava suggests 2/2/2 trigger conditions. • Increased roads of segments by a factor of 10(see Eric James’ talk at Purdue EMU meeting) • Number of chambers with 1 segment incresed from ~46K to ~74k