An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Polarized Source -- Improvements and Other Issues Ryan Snyder December 3, 2005

  2. Position Differences from the Pockels cell have two sources birefringence gradients and steering And… A good Pockels cell alignment can help to minimize these two factors

  3. Measuring Position Differences

  4. Pockels cell alignment • Maximize extinction between crossed LP’s -adjust pitch/yaw to maximize extinction • Adjust PC voltages and roll angle to minimize outgoing linear polarization • Do pitch/yaw scans (with downstream LP) and make indicated adjustments --> check dx, dy (biref. grad. + phase grad.) • Remove LP -->translate PC to minimize dx, dy (steering)

  5. Beam divergence • Very sensitive to interaction of beam angle with indices of refraction

  6. Hydrogen Setup DOLP = 99.8 % (upstream) -- not measured with IHWP IN With HV ON --DOLP ~ 4% --DOCP ~99.93%

  7. Pitch Scan = 7.6 um/turn

  8. Yaw Scan = -20.3 um/turn

  9. After pitch/yaw adjustment, IHWP OUT Dx = -0.41 +/- 0.23 um; Dy = -0.65 +/- 0.18 um But, with IHWP IN Dx = 3.6 +/- 0.29 um; Dy = 2.3 +/- 0.25 um A compromise was made…

  10. After pitch and yaw scans with IHWP IN a compromise was made IHWP IN Dx = 1.23 +/- 0.18um; Dy = 0.25 +/-0.23 um IHWP OUT Dx = 0.98 +/- 0.18 um; Dy = 0.70 +/- 0.23 um

  11. Steering -- Lever Arm = 88 cm IHWP OUT Dx = -0.20 +/- 0.17 um Dy = -0.17 +/- 0.18 um Aq = -190 ppm IHWP IN Dx = -0.12 +/- 0.12 um Dy = -0.09 +/- 0.13 um Aq = +198 ppm

  12. Problems and Other Issues Not Understood on Laser Table • Poor Initial Cancellation of Dx and Dy between IHWP IN and OUT • Sensitive to Dx with Pitch Scan and Dy with Yaw Scan • ~190 ppm Aq that flips sign from IHWP IN to OUT

  13. Helium setup (July on Gun 3) Helicity correlated electronics pickup up to Sept. down -- not related to laser table setup 2. Incoming DOLP = 95 % ==> DOCP = 30% -- 7 extra mirror bounces for Gun 3 compared to Gun 2 3. Pockels Cell alignment was very difficult 4. Large ~750 nm pos. diff. that flips sign with IHWP plate without an analyzer downstream of PC -- Lever Arm = 67 cm 5. More sensitive to pitch in y than x (makes sense); Also, more sensitive to yaw in y than x (doesn’t)

  14. Helium Setup -- July

  15. Helium Setup -- After Sept. Down

  16. Helium since Sept. down

  17. Hydrogen Setup -- Oct. 12th

  18. Drifts over time bpm1I02 -- first bpm after cathode Oct. 12th Dx = ~0 nm; Dy = 200 nm Oct. 17th Hall A Laser Lock fix Nov. 2nd Dx = 600 nm; Dy = ~0 nm Nov. 7th Dx = 600 nm; Dy = -150 nm Nov 8th -- > cathode spot move Nov. 10th Dx = 550 nm; Dy = -200 nm Nov. 17th Dx = 1.2 um; Dy = -800 nm