Time-Domain Calibration Update

Time-Domain Calibration Update. Xavier Siemens, Mike Landry, Gaby Gonzalez, Brian O’Reilly, Martin Hewitson, Bruce Allen, Jolien Creighton. S4 Feedback loop. Residual signal. External signal. + -. a C o. AS_Q. b. DARM_ERR =. Control signal. D o. + +. A. DARM_CTRL_EXC = m.

nova
Download Presentation

Time-Domain Calibration Update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Time-Domain Calibration Update Xavier Siemens, Mike Landry, Gaby Gonzalez,Brian O’Reilly, Martin Hewitson, Bruce Allen, Jolien Creighton

  2. S4 Feedback loop Residual signal External signal + - aCo AS_Q b DARM_ERR = Control signal Do + + A DARM_CTRL_EXC = m DARM_CTRL =

  3. + + S4 signal processing pipeline LP FIR LP FIR HP FIR - Reference functions digitised are for v1 calibration.- Factors (ab ) are computed at 1Hz.- All science data is available in the form of 256s frames (sometimes shorter at the end of a science segment).- Systematic errors at most ~1% in amplitude and ~1o in phase, between 30Hz and 3000Hz- The calibration lines, and anything else added to DARM_CTRL, approximately cancel. This includes ringing due to calibration line dropouts.

  4. Plans and Prospects - When final S4 calibration is out we’ll make the h(t) for it.- For S4, will change the pipeline to generate the control signal from DARM_ERR (not DARM_CTRL). This is due to some artefacts found in DARM_CTRL (see M. Landry’s talk coming up soon). Calibration accuracy at low frequencies (~30Hz) will most likely be degraded (a few percent in magnitude, a few degrees in phase). - For S5 will be running online under onasys (as during S4); hopefully the problem with DARM_CTRL will be fixed and we can use it to make h(t).

  5. Coming up: h(t) experimentation - Talks by: - Mike Landry for pulg - Stochastic group - Igor Yakushin for the burst group - Saikat Ray Majumder also for the burst groupMany thanks to them also to Laura Cadonati and Philip Charlton!