1 / 20

The one-arm stent for canalicular laceration

Mini Monoka. The one-arm stent for canalicular laceration. Simplified repair of canalicular laceration. Maintains proper alignment Prevents stricture after repair Soft, pliable silicone minimizes ocular irritation and tissue trauma Inert and stable. Monocanalicular intubation:

parker
Download Presentation

The one-arm stent for canalicular laceration

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Mini Monoka The one-arm stent for canalicular laceration

  2. Simplified repair of canalicular laceration • Maintains proper alignment • Prevents stricture after repair • Soft, pliable silicone minimizes ocular irritation and tissue trauma • Inert and stable

  3. Monocanalicular intubation: • Avoids manipulation of normal canaliculus and nasolacrimal duct (eliminating any possibility of injury to them) • Stents are easily placed (no intranasal manipulation) • May be placed using local anesthesia in an office or procedure room setting Monocanalicular vsBicanalicular

  4. Monocanalicular intubation (cont.): • Easy to remove at the slit lamp • No danger of “cheesewiring” or erosion of punctum (occasionally occurs with bicanalicular stents) • No need for any knots or sutures – stent is anchored at the punctum Monocanalicular vsBicanalicular

  5. For Canalicular Laceration or Imperforate Nasolacrimal Duct Wide/MediumCollarette Monoka

  6. Securely anchored at punctum by plug • Malleable stainless steel probe • Silicone tubing swaged into probe (less likely to separate) • No knots, no sutures Wide/MediumCollarette Monoka

  7. Wide/MediumCollarette Monoka Photos compliments of Mark Brown, MD – EyePlastics.com These photos show a canalicular laceration and its repair with a Monoka monocanalicular stent.

  8. Self-ThreadingMonoka Available in 3mm or 4mm collarette sizes

  9. Securely anchored at punctum by plug • Less traumatic (no metal to remove from nose) • Easier to retrieve from nose • Able to pass through tight passages without separating • No knots, no sutures Self-ThreadingMonoka

  10. Required Instruments • For all monocanalicular stents: •  Disposable plug inserter/dilator

  11. For the Self-Threading Monoka (and Ritleng Bicanalicular Stents): Reusable Ritleng Probe Reusable Ritleng Hook Required Instruments

  12. Ritleng Probe Procedure The Ritleng Probe is backed out of the lacrimal duct and separated from the polypropylene thread-guide at its thinner section (the light blue portion of the thread) by sliding it out from the open slit that lines the entire length of the probe. Figure 1

  13. Ritleng Probe Procedure The thinner section of the thread-guide is shown separating from the probe by sliding out from the open slit. Figure 2

  14. Ritleng Probe Procedure The Ritleng Probe is shown completely separated from the thread-guide. Figure 3

  15. Following dilation and preliminary probing of the lacrimal ducts, the Ritleng Probe is introduced into the canaliculus and nasolacrimal duct until contact is made with the nasal fossa floor. The probe is pulled back slightly (1cm) to facilitate the introduction of the prolene thread-guide into the nasal cavity. The probe is oriented with its slit side facing anteriorly and pushed backwards so that the interior end of the probe is facing anterior, thus directing the prolene towards the front of the nasal cavity. The prolene is threaded through the probe to obtain a large loop which spreads out in the nasal cavity making it easy to locate. Retrieval of the blue prolene is easy when it appears in the anterior portion of the nose. The prolene is retrieved under nasal illumination and visual control (nasal endoscope) with endonasal forceps with the Ritleng Hook. Ritleng Probe Procedure

  16. Ritleng Probe Procedure • If the prolene thread-guide is not easily located in the anterior portion of the nose, or if it takes a posterior direction, the following technique is used for retrieval: • The probe is introduced until contact is made with the nasal fossa floor. • Metal-to-metal contact is made using the Ritleng Hook high up in the inferior meatus near the exit of the nasolacrimal duct.

  17. Ritleng Probe Procedure The probe is then rotated 180° while keeping the metal-to-metal contact with the hook thus orienting its inferior opening towards the back. The hook should be above the probe’s opening and the prolene. This will enable the hook to catch the prolene loop when removing from the nose.

  18. Ritleng Probe Procedure The probe is slowly back out of the inferior meatus and as soon as the metal-to-metal contact between the probe and the hook is lost, the hook catches the prolene loop and is carefully removed from the nose. The probe is removed from the canaliculus and detached from the stent by sliding the thinner light blue portion of the prolene out through the probe’s slit. The prolene thread-guide is pulled out the nose along with the attached silicone tubing. This same technique is used to intubate the second canaliculus in the case of a bicanalicular intubation. In the case of a monocanalicular intubation, the punctal plug at the other end of the silicone tubing is seated in the puctum using a punctal plug dilator and inserter.

  19. Ritleng Probe Procedure Photos compliments of Mark Brown, MD – EyePlastics.com These photos show a canalicular laceration and its repair with a monocanalicular stent using the Ritleng probe.

  20. The Future in Sight Contact Information: FCI OPHTHALMICS P.O. Box 465 Marshfield Hills, MA 02051 Tel: 800-932-4202 Tel: 781-826-9060 Fax: 781-826-9062 Email: info@fci-ophthalmics.com Web: www.fci-ophthalmics.com