1 / 16

Wiremold ® OFR Series Overfloor Raceway System

Wiremold ® OFR Series Overfloor Raceway System. Introduction - Background. Need existed for divided pancake Primarily in fitness centers, classrooms. Open space areas where coming through floor or ceiling is not an option. On grade Trenching is too expensive

read
Download Presentation

Wiremold ® OFR Series Overfloor Raceway System

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Wiremold®OFR SeriesOverfloor Raceway System

  2. Introduction - Background • Need existed for divided pancake • Primarily in fitness centers, classrooms. • Open space areas where coming through floor or ceiling is not an option. • On grade • Trenching is too expensive • May not have access to floor below (different tenant) • Historical building

  3. Introduction - Background • Conference rooms with multiple service requirements • Power, Communications and AV • New classroom configurations • Pod style • Feeding Smart boards • Auditoriums for podiums • Increase in Communication and AV requirements

  4. Product Listing OFRB-8 8 ft base (4 per carton) OFRBC-8 8 ft base and cover (1 per carton) OFRC-8 8 ft cover (4 per carton) OFR10A Entrance End Fitting OFR48-2 2-Gang Device Box OFR48-4 4-Gang Device Box OFRWC Wire Clip OFR89-2400 Transition from 2400 Raceway to OFR OFR89-4000 Transition from 4000 Raceway to OFR OFR89-DS4000 Transition from DS4000 Raceway to OFR OFR89-VIS Transition from Vista Point5 to OFR

  5. Product Listing OFR11 Flat Elbow OFR1 Coupling OFR09 Grounding Clip OFR47-B Blank Device Plate OFR47-D Duplex Plate OFR47-R Decorator Plate OFR47-U Extron MAAP Plate OFR47-V Extron AAP Plate OFR47-2A Communication Device Plate OFR47-U2A Comb. AV/Comm Plate OFR48-4GX 4-Gang Device Box Crossover Kit

  6. System Features & Benefits • Low profile • Unobtrusive, ADA compliant design. • Installs in open space areas • Provides power, communications and AV wiring to areas where in-floor and ceiling distribution is not an option. • Multi-channel base • Provides space for multiple combinations of power, communications and AV in one raceway.

  7. System Features & Benefits • Open system device plates for data and AV • System can accommodate a wide variety of devices and manufacturers. • Attaches directly to floor covering (works with carpet, tile, wood, etc) • No need to alter existing floor covering. • Meets ADA Accessibility Guidelines • Raceway assembly is designed to meet the ADA Accessibility Guidelines as it pertains to ADA Standard 4.5 which addresses changes in floor and ground surface levels.

  8. System Features & Benefits • Black powder coat finish • Durable textured finish, blends with most decors. • Multiple transition options • Overfloor Raceway can be fed from the wall, DS4000, 4000 and 2400 Series Raceway as well as Vista Point5 Architectural Column. • Tamper resistant • Cover is difficult to remove without proper tools. • cETLus listed • Will be UL listed as well. • Will be stocked by electrical and communication distributors as well as AV Integrators • Product will be readily available in all channels.

  9. Product Features & Benefits Raceway Base and Cover • Unobtrusive, ADA compliant design. • 4 channel base for multiple services. • Cover has durable black powder coat finish. • Tamper resistant hex screws for cover. • Load tested to UL requirements for floor boxes (300 lbs. across 3” diameter).

  10. Product Features & Benefits Device Boxes and Plates • 4-gang box can accommodate power and communications on both sides with crossover kit. • Open system - power, communications and AV can go anywhere. • Side mounting of devices provides large cable bend radius inside raceway.

  11. Product Features & Benefits Transition Fittings • Wall mounted dual channel raceway can transition to any channel of OFR. • Entrance End Fitting has ½” and 1 ¼” KO Trade Size. • Raceway transitions available for 2400, 4000 and DS4000. Vista Point5 available as well.

  12. Applications • Fitness Centers • Treadmills, ellipticals, etc.

  13. Applications • Open Space Areas • Board Rooms and Conference Rooms • New style classroom pods

  14. Applications • Auditoriums • Lecterns, podiums

  15. Technical Information • cETLus listed • UL listing is pending • Meets ADA Accessibility Guidelines • ADA Standard 4.5

  16. Amusement Office Financial Education Retail Construction Hospitality Vertical Markets