97-0611 Modifications to the Latency Section of Performance Testing Baseline Text

97-0611 Modifications to the Latency Section of Performance Testing Baseline Text. Gojko Babic, Arjan Durresi, Raj Jain, Justin Dolske, The Ohio State University Contact: Jain@cse.ohio-state.edu http://www.cse.ohio-state.edu/~jain/. Overview. More precise measurement procedures

ted
Download Presentation

97-0611 Modifications to the Latency Section of Performance Testing Baseline Text

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 97-0611 Modifications to the Latency Section of Performance Testing Baseline Text Gojko Babic, Arjan Durresi, Raj Jain, Justin Dolske, The Ohio State University Contact: Jain@cse.ohio-state.edu http://www.cse.ohio-state.edu/~jain/

  2. Overview • More precise measurement procedures • Complete list and description of foreground and background traffic characteristics • Scalable test configurations • Reporting requirements

  3. Latency Measurement • Precise procedure description • Includes mean and standard deviations • Various intensities of foreground traffic (0+%, 50%, 75%, 87.5%, ...) • Various intensities of background traffic (0%, 50%, 75%, ... of max background load)

  4. Foreground Characteristics • Type of VCCs: PVP, SVP, PVC, SVC, • VCCs between ports on same/different modules/fabrics. “Same module” may or may not be better. • Service class: UBR, ABR • Arrival patterns: equally spaced frames, self-similar, random • Frame length: 64 B, 1518 B, 9188 B or 64 kB, variable; • Full foreground load (FFL) • Input rate/FFL = 0+, 0.5, 0.75, ... 1-2-k, k = 1, 2, ...

  5. Background Characteristics • Type of VCCs: PVP, SVP, PVC, SVC, • VCCs between ports on same/differentmodules/fabrics • Connection configuration: n-to-n straight, n-to-(n-1) full cross, n-to-m partial cross with m = 2, 3, 4, ...,n-1 • Service class: UBR, ABR, CBR, and VBR • Arrival patterns: equally spaced frames, self-similar, random • Frame length: 64 B, 1518 B, 9188 B or 64 kB, variable • Maximum background load (MBL) =  Link Rates • Input rate/MBL = 0, 0.5, 0.75, 0.875,... 1-2-k, k = 0, 1, 2, ...

  6. System under Test: ATM Switch P5Out A In P7 Out P5 In P7 In A Out P4Out P6Out P4 In P6 In ATM Monitor P1 Out P3Out P1 In P3 In P2Out P0 Out B In P2 In B Out P0 In Foreground traffic Background traffic Scaleable Test Configuration 7-to-7 Straight background VCs

  7. Motion • Adopt the text of 97-0611 to replace section 3.2 of Performance Testing Baseline Text.