An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Requirements of Sustainable Building Envelope Marco Citterio Enea – ENE SIST citterio@casaccia.enea.it 2006 26th June

  2. Aim of presentation To help Decision Makers in expressing their requirements to designers in early design phase of sustainable buildings

  3. Comparison of EU countries energy consumption in building sector

  4. Aspects: 􀂉 Building envelope thermal and permeability characteristics; 􀂉 HVAC and DHW plants; 􀂉 Efficient Lighting (specially in NR buildings); 􀂉 Building location and orientation, climate characterization included; 􀂉 Passive solar systems; 􀂉 Solar shading systems; 􀂉 Daylighting; 􀂉 Natural Ventilation; 􀂉 Indoor Environment Quality. European Directive about Energy Building Performance 91/2002

  5. “These (buildings) are properly designed, when due regard is had to the country and climate in which they are erected. For the method of building which is suited to Egypt would be very improper in Spain, and that in use in Pontus would be absurd at Rome: so in other parts of the world a style suitable to one climate, would be very unsuitable to another: for one part of the world is under the sun's course, another is distant from it, and another, between the two, is temperate.” “In the north, buildings should be arched, enclosed as much as possible, and not exposed, and it seems proper that they should face the warmer aspects. Those under the sun's course in southern countries where the heat is oppressive, should be exposed and turned towards the north and east. Thus the injury which nature would effect, is evaded by means of art.” Marcus Vitruvius Pollio: de Architectura, Book VI ,1,1-2 Ist century B.C.

  6. Could you tell where these buildings are located?

  7. 􀂉 passive measures (mainly involving architectural, morphological and building technology related variables) 􀂉 active measures (related to technological plants) Active and passive measures should be balanced in order to obtain indoor comfort conditions by means of right amount of energy and resources Indoor microclimate control can be obtained by means of interaction of

  8. Each envelope and building structure element has thermal capacity: capability of storing thermal energy and delaying heat transfer. Building envelope and thermal inertia

  9. Heavy structures have longer time response and limited thermal excursions in comparison to “lighter” structures. This fact helps to limit indoor temperature fluctuations due to seasonal and daily outdoor temperature variation.

  10. Energy consumption of buildings with high thermal inertia in cold or warm climates can be considerably lower than energy consumption of lighter buildings. Thermal energy storage in building mass sometimes allowes to shift the time of max cooling energy demand to time when building is not in use.

  11. The time lag φ represents the temporal delay of peak heat flow of actual wall compared to instantaneous heat flow of a wall with zero capacity; Decrement factor µ represents the ratio between max heat flow of actual wall and max heat flow of zero capacity wall.

  12. Φ and μ in function of mass and Uvalue

  13. Effectiveness of thermal inertia increases accordingly to day-night thermal excursion. In warm climates, walls store heat during the day and release it during the night: that is particularly effective in the case of building used during the day only. Thermal mass can also cooled by way of night ventilation (natural or mechanic) In cold climates, thermal mass helps in storing solar energy during the day, and mitigates indoor climate during the evening and the night.

  14. Influence of positioning thermal insulation on walls thermal inertia

  15. The right building orientation; The appropriate building shape; Rational spatial and functional organization of internal environments; can allow, with no extra costs: significant energy saving (30 – 40%) better indoor comfort Building shape and orientation

  16. Building should have the lower possible ratio between losing envelope surface and enclosed volume Building shape

  17. Take into account effects of prevailing winds due to building shape and boundary condition.

  18. The best solution is to orient the main building axis on east-west direction; South façades receive more solar radiation during winter (when the sun height is lower) than in summer. Building orientation

  19. Amount of solar radiation on different oriented surfaces for different latitudes

  20. Example of good internal layout of a residential building

  21. Transparent envelope and solar shading control can be obtained by means of: dimensioning and placing the right amount of glazed surfaces on different orientations • choosing the right glass characteristics (even accordingly to facade orientation) Adopting solar shading systems (preferably external) Solar shading control

  22. Glazed surfaces on North, East and West orientations should be dimensioned with the purpose of providing the right amount of daylighting. On North orientation, rarely reached by beam solar radiation, it is important to provide excellent thermal insulation to limit glazed surface dimensions

  23. Dimensioning glazed surfaces on South orientation, the right amount of daylight is not the matter: Windows can be enlarged in order to improve solar gains in winter. Solar shading adoption is anyway a must in order to limit and control solar gains during summer. Good Uvalue should be adviceable, in order to limit thermal losses in winter.

  24. The choice of glass typology is an important issue: Different kind of glasses available on the market, with variable optical characteristics, can fit with needs of different climate conditions (Selective glasses) Type of glasses

  25. Influence on PPD per different glass types during a sunny winter day

  26. External solar shading systems should be preferred: they shade solar radiation before it comes into the building. Solar shading

  27. On SOUTH orientation shading systems have to be horizontal: they are effective in order to limit solar gain during summer and allow solar gain in winter

  28. On EAST and WEST orientations vertical shading device have to be adopted. They shade solar radiation during early morning and late afternoon during summer.

  29. Thanks for your attention Acknowledgment: Simone Ferrari: “Progettazione Eco-sostenibile dell’involucro dell’edificio” - Progetto SICENEA - 2006 JRC – Directorate General for Energy (DG-XII): “Passive Solar Architecture for mediterranean area” THERMIE PROGRAM Commission of the European Communities, Brussels 1994