<br>Analytical system is equipped with a flow rate range of 0.0001 to 10 ml per minute. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 800 nm that analyses samples absorption at different wavelengths and a high pressure pump providing continuous consistent flow. Built in column heater provides reproducible retention time.
E N D
Personalized PDF Catalog Catalog Generated On : 30/11/2023 Analytical https://www.labtron.co | info@labtron.co Description : Analytical system is equipped with a flow rate range of 0.0001 to 10 ml per minute. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 800 nm that analyzes sample’s absorption at different wavelengths and a high pressure pump providing continuous consistent flow. Built in column heater provides reproducible retention time. Specifications :
Model No HPD-A20 HPD-A21 Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm ) Wavelength range Wavelength accuracy ± 0.5 nm ± 2 nm Wavelength repeatability 0.15 nm 0.3 nm Band width 8 nm 8 nm Optical path 10 nm 10 nm Deuterium lamp 190 to 400 nm 190 to 400 nm Detector Tungsten lamp 400 to 800 nm 400 to 800 nm Specifications Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5 Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4 Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8 Power 100 W 100 W Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm Weight 9.5 kg 9.5 kg
P M r Fl a e o x s C S w i s o a ra m u l m te u r Gradi u p Flow re Gradi Pump m e ent m l rate p ent Power Weig Flow rate range p p repeat Dimension Specifications n e accu e accur supply ht r u ability s s racy at acy % e l % i i a s s z z bi s a e e lit u t y r i % e o n 5 0 M P ≤ 4 a 1 . , % ± 6 0 a 0.15 × 5 ≤ 11.6 t t % at 460 × 310 × 0.0001 to 10 ml / min 2 µ 0. ± 1.5 ≤ 0.2 90 V kg o 1 1 ml 180 mm 5 m 1 2 0 / 0 m M min m l P m / a m i n
Features : Compression compensation ensuring gradient repeatability Low pressure gradient Detector ( Deuterium or tungsten lamp ) Automatic sample injector ( Autosampler ) 10 point calibration pump for linear pressure control Error alarm function for over pressure ,under pressure and leakage Applications : Used in pharmaceutical analysis, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity analysis
www.labtron.co Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom Email: info@labtron.co | Website: https://www.labtron.co/ | Phone: +44 2080 043 608