Recognition and Safe Handling of Meth Lab Waste

Recognition and Safe Handling of Meth Lab Waste. Colleen Brisnehan Environmental Protection Specialist Colorado Department of Public Health and Environment. What is Methamphetamine?. Powerful, highly toxic, addictive drug Illegally “cooked” in makeshift labs

Faraday
Download Presentation

Recognition and Safe Handling of Meth Lab Waste

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Recognition and Safe Handling of Meth Lab Waste Colleen Brisnehan Environmental Protection Specialist Colorado Department of Public Health and Environment

  2. What is Methamphetamine? • Powerful, highly toxic, addictive drug • Illegally “cooked” in makeshift labs • Can be found in the form of pills, capsules, powder or chunks • Can be smoked, snorted, injected or eaten • a.k.a. crank, speed, crystal or ice

  3. How is Meth Produced? • Red Phosphorous - ephedrine reduction with hydriodic acid, or by combining red phosphorous with iodine and water • Anhydrous Ammonia - ephedrine reduction with anhydrous ammonia and lithium or sodium metal • Phenyl-2-Propanone (P2P) – older, more complicated process using phenyl-2-propenane and methylamine

  4. Chemicals Related to Meth Production • Ephedrine or pseudoephedrine (cold tablets) • Acetone, toluene, alcohol or paint thinner • Iodine • Red phosphorous or phosphoric acid • Hydriodic acid • Naphtha, freon (camp stove fuel) • Ethyl ether (starter fluid)

  5. More Chemicals • Lithium metal (from batteries) • Sodium metal • Sulfuric acid • Muriatic acid (hydrochloric acid) • Sodium hydroxide (lye) • Hydrogen peroxide • P2P Method: mercuric chloride lead acetate

  6. Equipment Used in Meth Production • Pyrex or Corning dishes • Plastic or rubber tubing • Rubber gloves • Glass containers (all types) • Funnels • Propane tanks • Coffee filters • Hot plates

  7. By-products and Contaminants Related to Meth Production • Iodine/iodinated compounds • Phosphine gas • Yellow or white phosphorous (from overheating) • Hydriodic acid gas • Hydrogen chloride gas • Phosphoric acid gas • Meth residues

  8. Hazards of Meth Lab Waste • Iodine Stained Items • Iodine sublimes when heated • Upper respiratory and skin irritant, causing chest tightness, skin burns, rashes • IDLH 2ppm • Death Bags • Agitation will release phosphine gas • Severe pulmonary irritant, causing chest tightness, breathing problems, nausea, abdominal pain • IDLH 50ppm

  9. Hazards of Meth Lab Waste (cont.) • Acids and Bases • Skin, eye and respiratory tract irritation or burns • Solvents • Often flammable • Skin eye and respiratory irritants • Toxicity and exposure concerns vary by product • Anhydrous Ammonia • Containers under pressure can be explosive • Upper respiratory and skin irritant, contact with liquid causes caustic burns and frostbite

  10. Meth Lab Remediation Waste Reason to Be Concerned?

  11. National Jewish Research • Sampling during a controlled cooks • Vapor levels of phosphine, iodine and hydrogen chloride exceeded OSHA exposure levels at various times during cooks • High levels of airborne meth detected • Meth present on horizontal and vertical surfaces a significant distance from the cook area • Sampling conducted at inactive meth labs • High concentrations of meth detected • Acidic residues on surfaces and in porous material • Report available at: www.nationaljewish.org

  12. Meth Lab Remediation Waste • Contents of Structure • Contaminated personal property • Porous materials such as carpets and drapes • Cabinets, appliances, fixtures, furniture • Construction/Demo Debris • Dry wall, paneling • Flooring • Ceiling tiles • Insulation

  13. Disposal Requirements • Meth lab remediation waste may be disposed of as solid waste. • Notification to landfill must be provided for meth contaminated material. • Asbestos and lead paint abatement and disposal requirements must be followed. • Wash water can be containerized for offsite disposal or discharged to sanitary sewer with approval from POTW

  14. Special Precautions • Eliminate or limit contact - use equipment to handle if possible • Contaminated material is often wrapped in poly to limit cross contamination • Wear dermal protection if must handle material not wrapped in poly • Practice good hygiene - wash hands after handling contaminated material • Cover as soon as practical

  15. Additional Information Colleen Brisnehan colleen.brisnahan@state.co.us (303) 692-3357 Cleanup Regulationhttp://www.cdphe.state.co.us/op/regs/ boardofhealth/101403methlabrules.pdf