Certificate of Analysis HIGH FALLS 300MG N/A Matrix: N/A Page 1 of 6 High Falls Extracts 33 Irving Place New York NY, United States 10003 8452862118 support@highfallsextracts.com SAMPLE:GA90503001-001 METRC/Biotrack#n/aHarvest/Lot ID: n/a Batch#:19042301,Sample Size: 30ML -grams Ordered:05/03/19Sampled:05/03/19 Completed: 05/07/19Expires: 05/07/20 Sampling Method:SOP Client Method Image Safety Cannabinoids Analyte Weight(%) mg/g D9-THC 0.046 0.46 Pesticides - Passed Microbials - Passed Mycotoxins - Passed Heavy Metals - Passed Terpenes - NOT Tested Residual-Solvents - Passed Filth - Passed Water Activity - NOT Tested Moisture - NOT Tested THCa ND ND TOTAL THC 0.046 0.46 CBD 0.993 9.93 CBDa ND ND TOTAL CBD 0.993 9.93 CBN ND ND CBDV ND ND Cannabinoids D8-THC ND ND THCV ND ND 0.046% Total THC 0.993% Total CBD CBG ND ND CBGa ND ND CBC 0.03 0.3 13.8 297.9 TOTAL CANNABINOIDS 1.069 10.69 THC/Container CBD/Container ND ND ND ND ND ND ND ND 0.046 0.993 0.03 D9-THC THCa CBD CBDa CBN CBDV D8-THC THCV CBG CBGa CBC ___________________ Faris Hussain, Ph.D Lab Director 2444 NE 1st Blvd Suite 700 Gainesville, FL 32609 833-465-8378 info@eviolabsfl.com State License # n/a ISO Accreditation # 17025 This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds for human safety for consumption and/or inhalation.
Certificate of Analysis HIGH FALLS 300MG N/A Matrix: N/A Page 2 of 6 High Falls Extracts 33 Irving Place New York NY, United States 10003 8452862118 support@highfallsextracts.com SAMPLE:GA90503001-001 METRC/Biotrack#n/aHarvest/Lot ID: n/a Batch#:19042301,Sample Size: 30ML -grams Ordered:05/03/19Sampled:05/03/19 Completed: 05/07/19Expires: 05/07/20 Sampling Method:SOP Client Method Pesticides Daminozide Acephate Flonicamid Oxamyl LOQ 0.02 0.01 0.01 0.01 Action Level 1 0.4 1 1 Result ND ND ND ND Units ppm ppm ppm ppm Type Plant growth regulator Insecticide Pyridine Insecticide, Aphicide Carbamate Insecticide, Acaricide, Nematicide Carbamate Insecticide, Acaricide, Metabolite Neonicotinoid Insecticide Neonicotinoid Insecticide Organophosphate Insecticide, Acaricide, Metabolite Insecticide Neonicotinoid Insecticide, Molluscicide Insecticide, Nematicide Organophosphate Insecticide, Acaricide, Metabolite Carbamate Insecticide, Acaricide Insecticide, Nematicide Insecticide Imidazole Fungicide Phenylamide Fungicide Insecticide Organophosphate Insecticide, Acaricide Morpholine Fungicide Organophosphate Insecticide, Acaricide Carbamate Insecticide, Molluscicide, Bird repellent Fungicide Triazole Plant growth regulator; Fungicide Organophosphate Insecticide, Acaricide Triazole Fungicide Insecticide Tetramic acid Insecticide Insecticide, Nematicide Carbamate Insecticide Strobilurin Fungicide, Bactericide Triazole Fungicide Organophosphate Insecticide, Acaricide, Repellent Methomyl 0.01 0.4 ND ppm Thiamethoxam Imidacloprid Dimethoate 0.01 0.01 0.01 0.2 0.4 0.2 ND ND ND ppm ppm ppm Acetamiprid Thiacloprid 0.01 0.01 0.2 0.2 ND ND ppm ppm Aldicarb Dichlorvos 0.02 0.05 0.4 0.1 ND ND ppm ppm Propoxur Carbofuran Carbaryl Imazalil Metalaxyl Chlorantraniliprole Phosmet 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.2 0.2 0.2 0.2 0.2 0.2 0.2 ND ND ND ND ND ND ND ppm ppm ppm ppm ppm ppm ppm Spiroxamine Naled 0.01 0.01 0.4 0.5 ND ND ppm ppm Methiocarb 0.01 0.2 ND ppm Azoxystrobin Paclobutrazol 0.01 0.01 0.2 0.4 ND ND ppm ppm Malathion 0.01 0.2 ND ppm Myclobutanil Bifenazate Spirotetramat Ethoprophos Fenoxycarb Kresoxim-methyl Tebuconazole Diazanon 0.01 0.01 0.02 0.01 0.01 0.01 0.01 0.01 0.2 0.2 0.2 0.2 0.2 0.4 0.4 0.2 ND ND ND ND ND ND ND ND ppm ppm ppm ppm ppm ppm ppm ppm ___________________ Faris Hussain, Ph.D Lab Director 2444 NE 1st Blvd Suite 700 Gainesville, FL 32609 833-465-8378 info@eviolabsfl.com State License # n/a ISO Accreditation # 17025 This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds for human safety for consumption and/or inhalation.
Certificate of Analysis HIGH FALLS 300MG N/A Matrix: N/A Page 3 of 6 High Falls Extracts 33 Irving Place New York NY, United States 10003 8452862118 support@highfallsextracts.com SAMPLE:GA90503001-001 METRC/Biotrack#n/aHarvest/Lot ID: n/a Batch#:19042301,Sample Size: 30ML -grams Ordered:05/03/19Sampled:05/03/19 Completed: 05/07/19Expires: 05/07/20 Sampling Method:SOP Client Method Pesticides Propiconazole Clofentezine Spinosad (Spinosyn A) Prallethrin Trifloxystrobin Piperonyl butoxide LOQ 0.01 0.01 0.01 0.05 0.01 0.01 Action Level 0.4 0.2 0.2 0.2 0.2 3 Result ND ND ND ND ND ND Units ppm ppm ppm ppm ppm ppm Type Triazole Fungicide Tetrazine Acaricide Insecticide Synthetic pyrethroid Insecticide Strobilurin Fungicide Cyclic aromatic; Performance enhancer, Synergist Organophosphate Insecticide Carboxamide Acaricide Diphenyl oxazoline Acaricide Tetronic acid Insecticide Insecticide Pyrazolium Acaricide, Insecticide Pyridazinone Insecticide, Acaricide Pyrethroid Insecticide Insecticide Pyrethroid Insecticide Acaricide, Insecticide Phenylpyrrole Fungicide Phenylpyrazole Insecticide Pyrethroid Insecticide, Veterinary substance Organophosphate Insecticide, Acaricide Morpholine Fungicide Insecticide Insecticide Chlorpyrifos Hexythiazox Etoxazole Spiromesifen Pyrethrins (Pyrethrin I) Fenpyroximate Pyridaben Permethrins Abamectin B1a Etofenprox Bifenthrin Fludioxonil Fipronil Cypermethrin 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.05 0.02 0.01 0.01 0.01 0.02 0.02 0.2 1 0.2 0.2 1 0.4 0.2 0.2 0.5 0.4 0.2 0.4 0.4 1 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm Mevinphos 0.01 0.1 ND ppm Dimethomorph Coumaphos Spinosad (Spinosyn D) 0.01 0.01 0.01 0.1 0.2 0.2 ND ND ND ppm ppm ppm ___________________ Faris Hussain, Ph.D Lab Director 2444 NE 1st Blvd Suite 700 Gainesville, FL 32609 833-465-8378 info@eviolabsfl.com State License # n/a ISO Accreditation # 17025 This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds for human safety for consumption and/or inhalation.
Certificate of Analysis HIGH FALLS 300MG N/A Matrix: N/A Page 4 of 6 High Falls Extracts 33 Irving Place New York NY, United States 10003 8452862118 support@highfallsextracts.com SAMPLE:GA90503001-001 METRC/Biotrack#n/aHarvest/Lot ID: n/a Batch#:19042301,Sample Size: 30ML -grams Ordered:05/03/19Sampled:05/03/19 Completed: 05/07/19Expires: 05/07/20 Sampling Method:SOP Client Method Residual solvent Hexanes (2,3-dimethylbutane) 1,4-Dioxane Pentanes (iso-pentane) Pentanes (neo-pentane) Butanes (iso-butane) 2-Butanol 2-Ethoxyethanol 2-Propanol Acetone Acetonitrile Benzene Butanes (n-butane) Cyclohexane Dichloromethane Hexanes (2,2-dimethylbutane) Xylenes-O (1,2-dimethylbenzene) Xylenes-M (1,3-dimethylbenzene) Xylenes-P (1,4-dimethylbenzene) Ethanol Ethyl acetate Ethylbenzene Ethyl ether Ethylene Oxide Heptane n-Hexane Isopropyl acetate Methanol Hexanes (2-methylpentane) Hexanes (3-methylpentane) Pentanes (n-pentane) Propane Tetrahydrofuran Toluene Xylenes Action Level(ppm) 290 380 5000 5000 5000 5000 160 5000 5000 410 1 5000 3880 600 290 2170 2170 2170 5000 5000 2170 5000 50 5000 290 5000 3000 290 290 5000 5000 720 1068 2170 Pass/Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Results(ppm) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ___________________ Faris Hussain, Ph.D Lab Director 2444 NE 1st Blvd Suite 700 Gainesville, FL 32609 833-465-8378 info@eviolabsfl.com State License # n/a ISO Accreditation # 17025 This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds for human safety for consumption and/or inhalation.
Certificate of Analysis HIGH FALLS 300MG N/A Matrix: N/A Page 5 of 6 High Falls Extracts 33 Irving Place New York NY, United States 10003 8452862118 support@highfallsextracts.com SAMPLE:GA90503001-001 METRC/Biotrack#n/aHarvest/Lot ID: n/a Batch#:19042301,Sample Size: 30ML -grams Ordered:05/03/19Sampled:05/03/19 Completed: 05/07/19Expires: 05/07/20 Sampling Method:SOP Client Method Cannabinoid Profile Test Result-Analysis Method :SOP.T.40.020, SOP.T.30.050 Reagent LOT ID 030119.R02 050319.R01 050119.R01 Full spectrum cannabinoid analysis utilizing High Performance Liquid Chromatography with UV detection (HPLC-UV). (Method: SOP.T.30.050 for sample prep and Shimadzu High Sensitivity Method SOP.T.40.020 for analysis. LOQ for all cannabinoids is 1 mg/L). Filth and foreign Materials-Analysis Method :SOP.T.40.013 This includes but is not limited to hair, insects, feces, packaging contaminants, and manufacturing waste and by-products. An SH-2B/T Stereo Microscope is use for inspection. Mycotoxin Analysis-Analysis Method :SOP.T.30.065, SOP.T.40.065 Analyte Results Aflatoxin G2 ND Aflatoxin G1 ND Aflatoxin B2 ND Aflatoxin B1 ND Ochratoxin A+ ND Aflatoxins B1, B2, G1, G2, and Ochratoxins A testing using LC-MS. (Method: SOP.T.30.065 for Sample Preparation and SOP.T40.065 Procedure for Mycotoxins Quantification Using LCMS. LOQ 1.0 ppb). Total Aflatoxins (Aflotoxin B1, B2, G1, G2) must be <20µg/Kg. Ochratoxins must be <20µg/Kg. Micro Analysis-Analysis method :SOP.T.40.043 Pathogens Aspergillus_terreus_1J2 Aspergillus_niger Aspergillus_fumigatus Aspergillus_flavus Salmonella_specific_gene Escherichia_coli_Shigella_spp_ Total_Yeast_and_Mold Microbiological testing for Fungal and Bacterial Identification via Polymerase Chain Reaction (PCR) method consisting of sample DNA amplified via tandem Polymerase Chain Reaction (PCR) as a crude lysate which avoids purification. (Method SOP.T.40.043) If a pathogenic Escherichia Coli, Salmonella, Aspergillus fumigatus, Aspergillus flavus, Aspergillus niger, or Aspergillus terreus is detected in 1g of a sample, the sample fails the microbiological-impurity testing. Analytical Batch:GA003137 Consumables Id A83449360 FKVKOB 18/07/25 Dilution 10 Analytical Batch:GA003163 Action Level 0.02 0.02 0.02 0.02 0.02 Analytical Batch: GA003153 Results not present in 1 gram. not present in 1 gram. not present in 1 gram. not present in 1 gram. not present in 1 gram. not present in 1 gram. not present in 1 gram. ___________________ Faris Hussain, Ph.D Lab Director 2444 NE 1st Blvd Suite 700 Gainesville, FL 32609 833-465-8378 info@eviolabsfl.com State License # n/a ISO Accreditation # 17025 This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds for human safety for consumption and/or inhalation.
Certificate of Analysis HIGH FALLS 300MG N/A Matrix: N/A Page 6 of 6 High Falls Extracts 33 Irving Place New York NY, United States 10003 8452862118 support@highfallsextracts.com SAMPLE:GA90503001-001 METRC/Biotrack#n/aHarvest/Lot ID: n/a Batch#:19042301,Sample Size: 30ML -grams Ordered:05/03/19Sampled:05/03/19 Completed: 05/07/19Expires: 05/07/20 Sampling Method:SOP Client Method Pesticide Analysis-Analysis Method:SOP.T.30.065, SOP.T.40.065 Reagent LOT/ID 043019.R01 Analytical Batch :GA003162 Consumables ID 28065964 18/07/25 U1AX005180181025 Dilution Pesticide screen is performed using LC-MS which can screen down to below single digit ppb concentrations for regulated Pesticides. Currently we analyze for 57 Pesticides. (Method: SOP.T.30.065 Sample Preparation for Pesticides Analysis via LCMSMS and SOP.T40.065 Procedure for Pesticide Quantification Using LCMS). Heavy Metals Analysis-Analysis-Method:SOP.T.40.050, SOP.T.30.052 Reagent LOT/ID Dilution Heavy Metals screening is performed using ICP-MS (Inductively Coupled Plasma – Mass Spectrometer) which can screen down to below single digit ppb concentrations for regulated heavy metals using Method SOP.T.30.052 Sample Preparation for Heavy Metals Analysis via ICP-MS and SOP.T.40.050 Heavy Metals Analysis via ICP-MS. Metal Result Arsenic ND Cadmium ND Lead ND Mercury ND Abbreviation:ppm=Parts Per Million Residual SolventsAnalysis Method:SOP.T.40.032 Residual solvents screening is performed using GC-MS which can detect below single digit ppm concentrations. Currently we analyze for 34 Residual solvents. (Method: SOP.T.30.042 Residual Solvents Analysis via GC-MS). Analytical Batch: GA003150 Consumables ID Action-Level 1.500 0.500 0.500 3 Analytical Batch :GA003164 ___________________ Faris Hussain, Ph.D Lab Director 2444 NE 1st Blvd Suite 700 Gainesville, FL 32609 833-465-8378 info@eviolabsfl.com State License # n/a ISO Accreditation # 17025 This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds for human safety for consumption and/or inhalation.