An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Control Device Technology Barrett Parker, EPA, OAQPS

  2. Example Control Systems • 4 VOC control techniques plus capture discussion • 5 PM control techniques • 2 Acid gas control techniques • 3 NOx control techniques

  3. VOC Control Techniques – Carbon Adsorber • General description • Gas molecules stick to the surface of a solid • Activated carbon often used as it • Has a strong attraction for organics • Has a large capacity for adsorption (many pores) • Is cheap • Silica gel, activated alumina, and zeolites are also used

  4. VOC Control Techniques – Carbon Adsorber • General description (continued) • 3 types – fixed bed (most common), moving bed, and fluidized bed • Typically appear in pairs – one adsorbing while other desorbs • Used for control as well as recovery • Regenerated via steam, hot gas, or vacuum • Work best if molecular weight of compound between 50 and 200

  5. VOC Control Techniques – Carbon Adsorber – Fixed Bed Schematic

  6. VOC Control Techniques – Carbon Adsorber – Fixed Bed Examples

  7. VOC Control Techniques – Carbon Adsorber • Factors affecting efficiency • Presence, polarity, and concentration of specific compounds • Flow rate • Temperature • Relative humidity

  8. VOC Control Techniques – Carbon Adsorber • Performance indicators • Outlet VOC concentration • Regeneration cycle timing or bed replacement frequency • Total regeneration stream flow or vacuum profile during regeneration cycle • Carbon bed activity • Bed operating and regeneration temperature

  9. VOC Control Techniques – Carbon Adsorber • Performance indicators (continued) • Inlet gas temperature • Gas flow rate • Inlet VOC concentration • Pressure differential • Inlet gas moisture content • Leaks

  10. VOC Control Techniques – Carbon Adsorber – Manufacturer’s Specs

  11. VOC Control Techniques – Catalytic Oxidizer • General description • Waste gas gets oxidized to water and carbon dioxide • Catalyst causes reaction to occur faster and at lower temperatures • Saves auxiliary fuel

  12. VOC Control Techniques – Catalytic Oxidizer • General description (continued) • Catalysts allow lower operation temperatures (~ 650 to 1000°F) • Catalyst bed generally lasts from 2 to 5 years • Thermal aging, poisoning, and masking are concerns • Excess air is added to assist combustion • Residence time and mixing are fixed during design • Only temperature and oxygen can be controlled after construction

  13. VOC Control Techniques – Catalytic Oxidizer – Example Bricks

  14. VOC Control Techniques – Catalytic Oxidizer - Schematic

  15. VOC Control Techniques – Catalytic Oxidizer • Factors affecting efficiency • Pollutant concentration • Flow rate • Operating temperature • Excess air • Waste stream contaminants • Metals, sulfur, halogens, plastics

  16. VOC Control Techniques – Catalytic Oxidizer • Performance Indicators • Outlet VOC concentration • Catalyst bed inlet temperature • Catalyst activity • Outlet CO concentration • Temperature rise across catalyst bed • Exhaust gas flow rate

  17. VOC Control Techniques – Catalytic Oxidizer • Performance Indicators (continued) • Catalyst bed outlet temperature • Fan current • Outlet O2 or CO2 concentration • Pressure differential across catalyst bed

  18. VOC Control Techniques - Condenser • General description • Gas or vapor turns to liquid via • Lowering temperature or • Increasing pressure • Used as pretreatment to reduce volumes • Used to collect and reuse some solvents

  19. VOC Control Techniques - Condenser • General description (continued) • Two types – contact and surface condensers • No secondary pollutants from surface type • More coolant needed for contact type • Chilled water, brines, and CFCs used as coolants • Efficiencies range from 50 to 95 percent

  20. VOC Control Techniques – Condenser - Schematic

  21. VOC Control Techniques - Condenser • Factors affecting efficiency • Pollutant dew point • Condenser operating pressure • Gas and coolant flow rates • Tube plugging or fouling

  22. VOC Control Techniques - Condenser • Performance indicators • Outlet VOC concentration • Outlet gas temperature • Coolant inlet temperature • Coolant outlet temperature • Exhaust gas flow rate • Pressure differential across condenser

  23. VOC Control Techniques - Condenser • Performance indicators (continued) • Coolant flow rate • Pressure differential across coolant refrigeration system • Condensate collection rate • Inspection for fouling or corrosion

  24. VOC Control Techniques – Thermal Oxidizer • General description • Waste gas turns to carbon dioxide and water • Operating temperatures between 800 and 2000°F • Good combustion requires • Adequate temperature • Turbulent mixing of waste gas with oxygen • Sufficient time for reactions to occur • Enough oxygen to completely combust waste gas

  25. VOC Control Techniques – Thermal Oxidizer • General description (continued) • Only temperature and oxygen concentration can be controlled after construction • Waste gas has to be heated to autoignition temperature • Typically requires auxiliary fuel • Common design relies on 0.2 to 2 seconds residence time, 2 to 3 length to diameter ratio, and gas velocity of 10 to 50 feet per second

  26. VOC Control Techniques – Thermal Oxidizer - Schematic

  27. VOC Control Techniques – Thermal Oxidizer • Factors affecting efficiency • Waste gas flow rate • Waste gas composition and concentration • Waste gas temperature • Amount of excess air

  28. VOC Control Techniques – Thermal Oxidizer • Performance indicators • Outlet VOC concentration • Outlet combustion temperature • Outlet CO concentration • Exhaust gas flow rate • Fan current • Outlet O2 or CO2 concentration • Inspections

  29. VOC Control Techniques – Capture System • General description • Total efficiency is product of capture and control device efficiencies • Two types of systems • Enclosures and local exhausts (hoods) • Two types of enclosures • Permanent total (M204) – 100% capture efficiency • Nontotal or partial – must measure capture efficiency

  30. VOC Control Techniques – Capture System - Schematic

  31. VOC Control Techniques – Capture System • Factors affecting efficiency • System integrity • System flow

  32. VOC Control Techniques – Capture Systems • Performance indicators • Enclosures • Face velocity • Differential pressure • Average face velocity and daily inspections • Exhaust Ventilation • Face velocity • Exhaust flow rate in duct near hood • Hood static pressure

  33. PM Control Techniqes - Cyclone • General description • Particles hit wall sides and fall out • Often used as precleaners • Especially effective for particles larger than 20 microns • Inexpensive to build and operate • Can be combined in series or parallel

  34. PM Control Techniques – Cyclone - Schematic

  35. PM Control Techniques - Cyclone • Factors affecting efficiency • Component erosion • Inlet and outlet plugging • Acid gas corrosion • Air inleakage

  36. PM Control Techniques - Cyclone • Performance indicators • Opacity • Inlet velocity or inlet gas flow rate • Pressure differential • Inlet temperature

  37. PM Control Techniques – Electrostatic Precipitator • General Description • Charged particles are attracted to plates and removed from exhaust gas • Two types • Dry type use mechanical action to clean plates • Wet type use water to prequench and to rinse plates • High voltages are required • Multiple sections (fields) may be used • Efficiencies up to 99% can be obtained

  38. PM Control Techniques – Electrostatic Precipitator - Schematic

  39. PM Control Techniques – Electrostatic Precipitator - Schematic

  40. PM Control Techniques – Electrostatic Precipitators • Factors affecting efficiency • Gas temperature, humidity, flow rate • Particle resistivity • Fly ash composition • Plate length • Surface area

  41. PM Control Techniques – Electrostatic Precipitator • Performance indicators • Outlet PM concentration • Opacity • Secondary corona power (current and voltage) • Spark rate • Primary power (current and voltage)

  42. PM Control Techniques – Electrostatic Precipitator • Performance indicators (continued) • Inlet gas temperature • Gas flow rate • Rapper operation • Fields in operation • Inlet water flow rate (wet type) • Flush water solids content (wet type)

  43. PM Control Techniques – Electrified Filter Bed • General description • Charged particles are deposited on pea gravel • Three parts • Ionizer system • Filter bed • Gravel cleaning and recirculation system

  44. PM Control Techniques – Electrified Filter Bed - Schematic

  45. PM Control Techniques – Electrified Filter Bed • Factors affecting efficiency • Glaze build up on ionizer or gravel • Temperature • Performance indicators • Ionizer voltage and current • Filter bed voltage, current, and temperature • Inlet gas temperature

  46. PM Control Techniques – Electrified Filter Bed • Performance indicators (continued) • Pressure differential • Gas flow rate • Outlet PM concentration • Opacity

  47. PM Control Techniques – Fabric Filter • General description • Particles trapped on filter media, then removed • Either interior or exterior filtration systems • Up to 99.9% efficiency • 4 types of cleaning systems • Shaker (off-line) • Reverse air (low pressure, long time, off line) • Pulse jet (60 to 120 psi air, on line) • Sonic horn (150 to 550 Hz @ 120 to 140 dB, on line)

  48. PM Control Techniques – Fabric Filter - Schematic

  49. PM Control Techniques – Fabric Filter • Factors affecting efficiency • Filter media • Abrasion • High temperature • Chemical attack • Gas flow • Broken or worn bags • Blinding

  50. PM Control Techniques – Fabric Filter • Factors affecting efficiency (continued) • Cleaning system failure • Leaks • Re-entrainment • Damper or discharge equipment malfunction • Corrosion