510 likes | 1.09k Views
AWARENESS PROGRAM ON METER & HOUSE WIRING What is Electricity Meter A device to record Energy consumption. Meter Terminology No load Test Starting Current Current Range Influence parameters Meter Type v/s Recording If Load is 2 AC, 1 Geyser, 1 Fridge, 1 TV, 20 bulb
E N D
What is Electricity Meter A device to record Energy consumption.
Meter Terminology • No load Test • Starting Current • Current Range • Influence parameters
Meter Type v/s Recording • If Load is 2 AC, 1 Geyser, 1 Fridge, 1 TV, 20 bulb • Current ……………… 38 Amp • Sr. No Rating Recording 1.0 2.5~5A ( Mech.) Read 15% 2.0 5A~10A ( Mech.) Read 26% 3.0 5A~20A (mech.) Read 53% 4.0 10~40A(Mech.) Read Okay 5.0 10~60A ( Elect.) Read Okay
BSES Electronic Meters • Specification • Rating 10~60A • Starting 0.2% • Kwh and MD in KW • TOD, 6 Tariff and 6 time zone • 6 Month Billing data • RS232C • Transformer supply
FAQ • Why Mechanical meter Read less • Influence Parameters • Age • Wear and Tear • Narrow Range • Mounting • Dust and Oil effect • Mechanical Counters
FAQ • Why electronic meter are preferred • Wide Range • Low starting current • Less effect of Influence parameters • More accurate • Temper proof
ROLE OF LED N-CUT CAL LED EL REV LED
ROLE OF LED CAL LED High resolution Out Put devices for Meter checking
ROLE OF LED REV LED • * Indicate Reverse flow of • Energy • Reason • * Wrong wiring • * Use of un isolated • Generator/ Inverters
ROLE OF LED EL • Due to Unbalance Current. • Need Attention
ROLE OF LED N- Cut • Indicate Current without • Voltage on Meter • Contact DISCOM • immediately
KNOW ABOUT EL The glowing of the EL LED indicates the following: Earth is being used as neutral. Neutral is touching the earth. Phase / Neutral wire is touching with the neighbors phase / Neutral wire. Neutral wire is interconnected with the neighbors neutral wire.
KNOW ABOUT EL • Wrong wiring, among others things can result in: • Safety hazards (wires are still live, even when the main switch is off). • Cause fire (if by mistake phase and neutral wires get interchanged) • Wrong Current flow (the neighbours current can flow through your meter)
Good electronic meters have Current sensorsinboththe Phase path, and Neutral path For Measurement it choose higher*of the two current. * In general Phase current is used for measurement however if neutral Current more by 10~ 12 % then Neutral current selected
Electro-mechanical Meter has Current sensoronly on one wire All Measurement based on phase wire current even when connected to neutral.
Good electronic meters have Current sensorsinboththe Phase path, and Neutral path This is an advantage of electronic meters over electromechanical meters Never buy electronic meters without this feature But neutral looping may cause the meter to “run Extra”
KNOW ABOUT EL If EL ON, get your internal wiring checked for any leakages and other problems and also carefully look at the EL LED in the Electronic Meters. EL LED, in Electronic Meters, however small, is of great importance and consumers are advised not to ignore its usefulness.
HOUSE DISTRIBUTION BOX METER MCB / Switch Fuse Phase Neutral D. Box
NORMAL CONNECTION I red = I yellow E mech= Eelect
NORMAL CONNECTION I red < I yellow E mech< Eelect JUMPER
INPUT PHASE / NEUTRAL INTERCHANGE I red = I yellow E mech= Eelect NO EFFECT NO EFFECT
NEUTRAL TOUCHING TO EARTH I white <I red (EL on) Electronic = I red Mechanical = I red EL glow E mech= Eelect NO EFFECT
INTERCHANGE LINE & NEUTRAL EARTH SHIFTING EL glow I red>I white (EL on) Electronic = I red Mechanical = I white Mechanical read less
INTERCHANGE LINE & NEUTRAL EARTH SHIFTING I white = 0 EL glow I red>I white (EL on) Electronic = I red Mechanical = Nil Mechanical read Nil
ELECTRONIC METER RECORD CORRECTLY No Effect
COMMON NEUTRAL Meter Recording As per Neutral Current (Extra) As per Phase current (okay)
COMMON NEUTRAL 15A 15A 15A (15+5) A 15A 5A 15A 15A 15A 10A
COMMON NEUTRAL 15A 15A 15A 14.5A 15A 0.5A 15A 15A 15A (15+0.5) A
COMMON NEUTRAL 15A 15A 15A 10A 15A 5A 15A 15A 15A (15+5) A
Wiring Defect Type Of Defects • Distribution Box • Wiring
Distribution Box • Use of DP- MCB/ Isolator. • Ensure ELCB. • For more than 10 Amp ckts. • Separate MCB. • Neutral Bus-bar. • Correct fuse & wire size.
ELCB FUSE MCB Proper Installation
Wiring Defect • Earth (No Neutral) • N-E • Common N • Common P • Combination
Wiring Defect Tools • Clamp on tester • Bulb tester • Line tester • Electrician Kit.
HOUSE DISTRIBUTION BOX METER MCB / Switch Fuse Phase Neutral D. Box GLOW
HOUSE DISTRIBUTION BOX METER MCB / Switch Fuse Phase Neutral D. Box GLOW
Wiring Defect Step-1. If no. of Meter in one Premise is only one then there is no common Neutral problem.
Step-2. Load On Check I phase & I neutral If I neutral = 0 Earth is used. METER Phase 10A Neutral 0A EARTH Common Neutral EL NE
Step-3. If Neutral remove from MCB still load working than wiring problem. If total MCB Off and still load working, then both wire sharing.
Step-4. At MCB If Phase Off, then EL Off Means Neutral-Earth Problem. Step-5. If neighbour Phase Off Then EL Off , Means Common wire.
Phase Neutral EARTH Phase Neutral EARTH
Step-6. If V EN≠ 0 Then Earth not touching Neutral Step-7. If common wire Disconnect one by one Neutral Ckt. From Bus-bar & see if EL off.
Step-8. Once Ckt. Identified then repair The defect. Step-9. Once again check all current. i.e. Ip = In
HOUSE DISTRIBUTION BOX METER MCB / Switch Fuse Phase Neutral D. Box GLOW
Typical Defect Pts. Common Load. E.g. Motor Stair Case Light (i.e. two way switch. Common Invertors /Generator. Houses with separate power & light meter.
Typical Pts. Where Earth gets common with neutral Metallic body Appliances. Appliances connected with metal pipe line. Building RCC.
!!Beware!! Meter can only be touch by Discom (BSES) employee.