An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Training Session on Energy Equipment Monitoring Equipment Presentation to Industry Energy Efficiency Guide for Asia Chapter 15 Monitoring Equipment © UNEP GERIAP

  2. Training Agenda: Monitoring Equipment Electrical measuring instruments Combustion analyzer Manometers Thermometers Water flow meters Speed measurement Leak detectors Lux meters Monitoring Equipment © UNEP 2005

  3. Electrical Measuring Instruments What Do They Do? • Measures major electrical parameters such as KVA, KW, PF, Hertz, KVAr, Amps and Volts, sometimes also harmonics • Instant measurements can be taken with hand-held meters, while more advanced facilitates cumulative readings with print outs at specified intervals Monitoring Equipment © UNEP 2005

  4. Electrical Measuring Instruments What Do They Do? • The HIOKI 3286-20 clamp on power hitester • measures: Monitoring Equipment • Voltage • Current • Voltage/current peak • Effective / reactive / apparent power (single-phase or 3-phase) • Power factor • Reactivity • Phase angle • Frequency, • Phase detection(3-phase) • Voltage/current harmonic levels (up to 20th) Figure: HIOKI 3286-20 clamp on power hitester © UNEP 2005

  5. Electrical Measuring Instruments Where & How to Use? • These instruments are applied on-line to measure various electrical parameters • Have three leads connected to crocodile clips at the end • The three leads are colored yellow, black and red Monitoring Equipment Figure: Power and power factor measurement on single phase three wire circuit © UNEP 2005

  6. Electrical Measuring Instruments Precautions • The clamp should never be attached to a circuit that operates at more than maximum rated voltage, or over bare conductors • Clamp on probe should be connected to the secondary side of a breaker • Rubber hand gloves, boots, and safety helmet should be used to avoid electrical shocks • The operation manual should be consulted before using the equipment Monitoring Equipment © UNEP 2005

  7. Training Agenda: Monitoring Equipment Electrical measuring instruments Combustion analyzer Manometers Thermometers Water flow meters Speed measurement Leak detectors Lux meters Monitoring Equipment © UNEP 2005

  8. Combustion Analyzer What Does It Do? • Measures the composition of flue gases after combustion Monitoring Equipment • Basically all combustion analyzers measure the % Oxygen or CO2 in the flue gases • The efficiency can be calculated with an inbuilt programme Figure: A fyrite combustion analyzer © UNEP 2005

  9. Combustion Analyzer Where & How It’s Used • Determines the composition of flue gases in the duct, which flushes out the combusted gases to the chimney • The flue gases’ composition values are based on volume Monitoring Equipment Figure: A gas combustion analyzer • Usually measure the % CO2 or O2 and the temperature of the flue gas • Mostly, the flue gases are sucked out in order to react with chemical cells that enables the reading of O2 or CO2 © UNEP 2005

  10. Combustion Analyzer Precautions • Always calibrate the instrument in open fresh air before taking a set of measurements • Check for clogging of the air filters • Ensure that the rubber tubing carrying the gases to the instrument is not bended • Wrap the opening space left by cotton rags to ensure that there is no in- or exfiltration of air • Use of hand gloves, goggles and safety helmet • Safety and precautions should be consulted from the operation manual Monitoring Equipment © UNEP 2005

  11. Training Agenda: Monitoring Equipment Electrical measuring instruments Combustion analyzer Manometers Thermometers Water flow meters Speed measurement Leak detectors Lux meters Monitoring Equipment © UNEP 2005

  12. Manometers What Does It Do? • A manometer is a pressure measuring instrument that measure the differential pressure across two points • The liquid-column manometer is the oldest type and can be a simple U-shaped tube that is half-full of liquid • The pressure to be measured is applied to one side of the tube and is then represented by the difference in liquid levels in the tube legs Monitoring Equipment © UNEP 2005

  13. c a b Manometers Principles • The manometer is a U-tube half filled with liquid. When both ends of the tube are open, the liquid is at the same height in each leg. • When positive pressure is applied to one leg, the liquid is forced down and up in the other leg. The difference in height, "h” indicates the pressure. Monitoring Equipment • When vacuum is applied to one leg, the liquid rises in that leg and falls in the other. The difference in height, "h," indicates the amount of vacuum. h h Figure: Principles of a manometer © UNEP 2005

  14. Manometers Types of Manometers • A single-limb liquid-column manometer use a large reservoir and a scale beside a narrower column and can be used to measure small differences between great pressures • Use the deflection of a flexible membrane that seals a fixed pressure reference volume to determine the pressure • Use a coiled tube that as it expands due to pressure increase causes rotation of an arm connected to the tube Monitoring Equipment © UNEP 2005

  15. Manometers Where & How It’s Used • The air velocity in ducts can be measured using a pitot tube and inclined manometer for further calculation of flows • The difference in level of the manometer gives the total velocity pressure • The two openings at the end of the pitot tube are always connected to the two openings of the manometer Monitoring Equipment Precautions • Should not be exposed to very high pressures © UNEP 2005

  16. Training Agenda: Monitoring Equipment Electrical measuring instruments Combustion analyzer Manometers Thermometers Water flow meters Speed measurement Leak detectors Lux meters Monitoring Equipment © UNEP 2005

  17. Thermometers Contact Thermometer • Consists of two dissimilar metals that are joined together at one end • As the temp. changes at the junction of the two metals, a voltage is produced that can be correlated back to the temp. • Measures flue gas, hot air and hot water temp. through a probe in the stream • The four most common calibrations are J, K, T and E, and those for high temperature calibrations include R, S, C and GB Monitoring Equipment © UNEP 2005

  18. Thermometers Non Contact Type or Infrared Thermometer • Based on the principle that all objects emit infrared energy: • “The hotter the object, the more active its molecules, and the more infrared energy is emitted” • Useful for measuring hot spots in furnaces, surface temperatures etc • Allows measurements in applications where conventional sensors can’t be employed Monitoring Equipment © UNEP 2005

  19. Thermometers Where & How It’s Used • Temperatures are generally recorded for air conditioning units, boilers, furnaces, steam systems, waste heat recovery systems and heat exchangers Monitoring Equipment • The probe or bulb has to be insterted into the fluid or gases that are to be measured Figure: Thermocouple © UNEP 2005

  20. Thermometers Precautions • The probe must be immersed in the fluid and the measurement must be taken after 1-2 minutes • The range for which the thermocouple is made for should be noted beforehand • The probe of the thermocouple should never touch the naked flame • The emissivity should be set according to the surface where the temperature is to be measured Monitoring Equipment © UNEP 2005

  21. Training Agenda: Monitoring Equipment Electrical measuring instruments Combustion analyzer Manometers Thermometers Water flow meters Speed measurement Leak detectors Lux meters Monitoring Equipment © UNEP 2005

  22. The distance traveled by the ball / time taken Water Flow Meters What Does it Do? • Measures linear, nonlinear, mass or volumetric flow rate of a liquid or a gas • The time of fill method: The time it takes to fill up a certain volume is recorded and the average flow can be calculated • The float method: The time it takes for a ping pong ball to travel a known distance and the surface velocity calculated: Monitoring Equipment © UNEP 2005

  23. Water Flow Meters Type of Water Flow Meters • The rotameter is a tapered tube and a float used for gases and liquids • The piston-type flowmeters is an economical alternative that use an annular orifice formed Monitoring Equipment • by a piston and a tapered cone • Ultrasonic flowmeters is used for liquids and are commonly used in dirty applications such as wastewater Figure: Ultrasonic flowmeters © UNEP 2005

  24. Water Flow Meters Type of Water Flow Meters • Turbine flow meters is a very accurate meter used for clean and viscous liquids • Paddlewheel sensors are cost effective flow meters for water or water like fluids • Positive displacement flowmeters are used when no straight pipe is available • Vortex meters have low sensitivity to variations in process conditions • Magnetic flow meters do not have any moving parts and are ideal for dirty liquids Monitoring Equipment © UNEP 2005

  25. Water Flow Meters Where & How It’s Used? • Cases where measurement of water flow is absolutely essential include the efficiency of pumps and cooling towers, chillers and air conditioning plants, heat exchangers, condensers etc Monitoring Equipment Precautions • Thorough cleaning of the measuring spot • Ensure the internal is not corroded • Measure where the pipe flow is expected to be laminar and the pipe must be flowing full © UNEP 2005

  26. Training Agenda: Monitoring Equipment Electrical measuring instruments Combustion analyzer Manometers Thermometers Water flow meters Speed measurement Leak detectors Lux meters Monitoring Equipment © UNEP 2005

  27. Speed Measurement Tachometers and Stroboscopes • A tachometer is a contact type instrument that can be used where direct access is possible • A stroboscope is a source of flashing light that can be synchronized with any fast, repetitive motion so that a rapidly moving device seems to stand still, or to move slowly Monitoring Equipment Figures: A stroboscope to the left and a tachometer to the right © UNEP 2005

  28. Speed Measurement Tachometers and Stroboscopes • Tachometers (contact type): • Used to measure the speed of rotation of a motor or pulley etc • The wheel is brought in contact with the rotating body that due to the friction obtains the same speed • Stroboscope: • This is a versatile flashing light source used to: • a) measure the speed of fast-moving objects or • b) to produce the optical effect of stopping or slowing down high-speed motion for observation, analysis, or high-speed photography Monitoring Equipment © UNEP 2005

  29. Speed Measurement Precautions • While using a contact type tachometer, care should be taken while bringing the wheel of the tachometer in contact with the rotating body • Loose clothing should never be worn while taking measurements with a tachometers • Taking measurements alone should be avoided Monitoring Equipment © UNEP 2005

  30. Training Agenda: Monitoring Equipment Electrical measuring instruments Combustion analyzer Manometers Thermometers Water flow meters Speed measurement Leak detectors Lux meters Monitoring Equipment © UNEP 2005

  31. Leak Detectors What Does It Do? • Detects the ultrasonic sound of a leak • As long as the leak is turbulent, there will be enough sound to detect it ultrasonically • A leak test can be done in an enclosed area which is saturated with refrigerant • The electronic process heterodyning converts the high frequency leak sound to a lower range Monitoring Equipment © UNEP 2005

  32. Leak Detectors Where & How It’s Used? • The probe is slowly moved close to the gas or steam pipe line • Where the leak is a hissing sound can be heard through headphones Monitoring Equipment Figures: Leak detector © UNEP 2005

  33. Leak Detectors Precautions • Dust or smoke should not come out of the pipe • Avoid measurement at the places where sound level is high • Safety precautions should be consulted from the operation manual Monitoring Equipment © UNEP 2005

  34. Training Agenda: Monitoring Equipment Electrical measuring instruments Combustion analyzer Manometers Thermometers Water flow meters Speed measurement Leak detectors Lux meters Monitoring Equipment © UNEP 2005

  35. Lux Meters What Does It Do? • Consist of a body, a photo cell and a readout • Light energy is transferred by the photo cell into an electric current that the meter calculates to the appropriate value of Lux or Foot candles • A standard color can be referred to as color temperature and is expressed in degrees Kelvin • The readings will vary with different light sources Monitoring Equipment © UNEP 2005

  36. Lux Meters Where & How It’s Used? • The sensor is placed at the work station or where the light intensity will be measured • The instrument will directly give the reading Monitoring Equipment Figures: Lux meter © UNEP 2005

  37. Lux Meters Precautions • The sensor should be properly placed on the workstation • Due its high sensitivity, the sensor should be kept safely • Safety and precautions should be consulted from the operation manual Monitoring Equipment © UNEP 2005