<br>High-Performance Liquid Chromatography (HPLC) is a powerful analytical technique <br>for separating, identifying, and quantifying compounds in complex mixtures. Its <br>high resolution and sensitivity make it a vital tool in pharmaceutical, environmental,<br>and biochemical analysis, ensuring accurate and reliable results.

Mary238
Download Presentation

High-performance-liquid-chromatography

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High performance liquid chromatography info@labotronics.com www.labotronics.com

  2. Overview High performance liquid chromatography is a unit with a flow range 0.001 mL / min to 10.000 mL / min. It has a UV detector of wavelength range 190 nm to 700 nm and a deuterium light source which has high stability and high-intensity. Specifications : Isocratic Pump (1 set) Double plunger reciprocating pump 0.001 mL / min̴ 10.000 mL / min Flow range Setting step size 0.001 mL / min Flow accuracy ≤ ± 0.3 % ( 1.00 ml / min, H2O , R.T. , 8.5 MPa ) Flow stability RSD ≤ 0.1 % ( 1.00 ml / min, H2 O , R.T , 8.5 MPa ) Pump specifications Maximum pressure 42 Mpa ≤ ± 3.0 % Display pressure error Pressure fluctuation ≤ 1.0 % 80 W Power dissipation

  3. Wavelength repeatability Wavelength accuracy ± 0.1 nm ≤ ± 1.0 nm Spectrum band width 8 nm 0.0 secs to 4.9 secs Response time Linearity range1.8 AU ( 5 % ) Baseline noise ≤ ± 1 × 10 - 5 AU Wavelength range 190 nm ~ 700 nm Baseline drift ≤ 2.0 × 10-4 AU / h Detector specifications 4.0 × 10-9 g / mL ( Naphthalene in Methanol Solution ) Optical Path - 10 mm Minimum detectable concentration Detector cell Volume - 10 μl Deuterium Lamp Light source Power dissipation Power supply 100 W AC 110 V / 220 V ± 10 %, 50 Hz / 60 Hz Features : VFD screen for process control Deuterium light Gradient mixer for effective centrifugation gradients

  4. Optical path detector cell of volume 10µL One set double plunger reciprocating pump Applications : Used to split a mixture of compounds in the fields of analytical chemistry, biochemistry and industrial. Standard Accessories : Accessory NoAccessory 1) Sample injector 2) 3) HPLC column ( 5 µm, ID 6 × 200 mm ) Work station 4) 5) Value mounting frame Isocratic system kit Labotronics Ltd. Union House, 111 New Union Street, Coventry CV1 2NT, UK info@labotronics.com | www.labotronics.com