This is an advanced high-performance liquid chromatography system, <br>offering precision in separating and analyzing complex mixtures. <br>With its high resolution and sensitivity, it is ideal for pharmaceutical, <br>environmental, and biochemical applications, ensuring accurate and reliable <br>results in analytical science.

Mary238
Download Presentation

High-performance-liquid-chromatography-LB-11HPLC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High performance liquid chromatography LB-11HPLC info@labotronics.com www.labotronics.com

  2. Overview High performance liquid chromatography LB-11HPLC is a unit with a flow range 0.001 mL / min to 10.000 mL / min. It has a UV detector of wavelength range 190 nm to 700 nm and a deuterium light source which has high stability and high-intensity. Specifications : Double plunger reciprocating pump Binary high pressure gradient pump(2 set) 0.001 mL / min ̴ 10.000 mL / min Flow range Setting step size 0.001 mL / min ≤ ± 0.3 % ( 1.00 ml / min, H O , R.T. , 8.5 MPa ) Flow accuracy 2 RSD ≤ 0.1 % ( 1.00 ml / min, H O , R.T , 8.5 MPa ) Pump specifications 2 Flow stability Maximum pressure 42 Mpa Display pressure error ≤ ± 3.0 % Pressure fluctuation ≤ 1.0 % Power dissipation 80 W

  3. Wavelength repeatability ± 0.1nm Wavelength accuracy ≤ ± 1.0 nm Spectrum band width 8 nm Response time 0.0 sec ̴ 4.9 sec Linearity range 1.8 AU ( 5 % ) Baseline noise ≤ ± 1×10 – 5 AU Wavelength range 190 nm - 700 nm Baseline drift ≤2.0 × 10 - 4 A U / h Detector specifications 4.0×10-9 g / mL (Naphthalene in Methanol Solution) Minimum detectable concentration Optical Path—10 mm Detector cell Volume—10 μL Light source Deuterium Lamp Power dissipation 100 W AC 110 V / 220 V ± 10 %, 50 Hz / 60 Hz Power supply Features : VFD screen for process control Deuterium light source Optical path detector cell of volume 10µL One set double plunger reciprocating pump    

  4. Applications : Used to split a mixture of compounds in the fields of analytical chemistry, biochemistry and industrial. Standard Accessories : Accessory NoAccessory 1) Sample injector 2) HPLC column ( 5 µm, ID 6 × 200 mm ) 3) Work station 4) Value mounting frame 5) Gradient system kit Labotronics Ltd. Union House, 111 New Union Street, Coventry CV1 2NT, UK | info@labotronics.com www.labotronics.com