1 / 4

High-performance-liquid-chromatography-LB-22HPLC

It represents the pinnacle of high-performance liquid chromatography, offering exceptional<br>precision in separating and analyzing complex samples. With advanced features, it ensures <br>rapid and reliable results, setting a new standard for efficiency and accuracy in analytical <br>processes.

Mary238
Download Presentation

High-performance-liquid-chromatography-LB-22HPLC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High performance liquid chromatography LB-22HPLC info@labotronics.com www.labotronics.com

  2. Overview High performance liquid chromatography is a unit with flow range of 0.001 mL / min to 10.000 mL / min. It is equipped with classic short stroke and multi-stage flow correction which ensures pump performance. It has a UV detector of wavelength range 190 nm to 700 nm.It consists of a 4 chamber integrated vacuum degasser Built-in autosampler improvises unit automaticity, matching with a variety of HPLC system. Specifications : Quaternary low pressure gradient pump(1 Set) Pump Flow rate range 0.001 mL / min̴ 10.000 mL / min ≤ ± 0.2 % (1.00 ml / min, H2O, R.T., 8.5 MPa) RSD ≤ 0.075 % (1.00 ml / min, H2O ,R.T., 8.5 MPa) Flow accuracy Pump specifications Flow precision Maximum pressure Pressure accuracy 45 MPa ≤ ± 3.0 % Pressure pulsation ≤0.1 MPa

  3. Wavelength range 190 nm̴ 700 nm Wavelength repeatability ≤ 0.1 nm Wavelength accuracy ≤ ± 1.0 nm Band width 8 nm Detector specifications Response time 0.0 sec̴ 5 sec Baseline noise ≤ ± 0.5 × 10 - 5 AU Drift ≤1.0 × 10-4 AU / h 10 mm (analytical cell) Path length Light source Deuterium Lamp AC 110 V / 220 V ± 10 %, 50 Hz / 60 Hz Power supply Features : Concave surface holographic grating Self-developed PID control measure 4 chamber integrated vacuum degasser Sequence tables for any set of samples Internal and external standard calculation methods All-round upgraded workstation Prints, exports and starts other programs after the completion of a measurement Applications: Used to split a mixture of compounds in the fields of analytical chemistry, biochemistry and industrial.

  4. Labotronics Ltd. Union House, 111 New Union Street, Coventry CV1 2NT, UK info@labotronics.com | www.labotronics.com

More Related