An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High performance liquid chromatography LB-30HPLC info@labotronics.com www.labotronics.com

  2. Overview High performance liquid chromatography LB-30HPLC is a unit with flow rate range of 0.001 ̴ 10.000 mL / min, in 0.001 mL. It has a wavelength range of 190 nm to 800 nm. Isocratic pump type unit that is equipped with specially designed column oven for GPC. Specifications : Quaternary low pressure gradient pump(1 Set) Pump Flow rate range 0.001 mL / min ̴ 10.000 mL / min ≤ ± 0.2 % (1.00 ml / min, H O, R.T., 8.5 MPa) Flow accuracy 2 Pump specifications RSD ≤ 0.075 % (1.00 ml / min, H O ,R.T., 8.5 MPa) Flow precision 2 Maximum pressure 45 MPa Pressure accuracy ≤ ± 3.0 % Pressure pulsation ≤ 0.1 MPa

  3. Wavelength Range 190 nm ̴ 800 nm Wavelength Repeatability ≤ 0.1 nm Wavelength Accuracy ≤± 1.0 nm Band Width 6 nm Response Time 0.0 s ̴ 5 s ≤ ± 0.25 × 10 -5AU (empty cell, 254 nm, 1.0 s) Detector specifications Baseline Noise ≤0.5 × 10-4AU/h (empty cell, 254nm, 60min) Drift Path length 10 mm(analytical cell) Deuterium Lamp and Tungsten Lamp Light Source AC110/220V±10%, 50/60Hz Power Supply Features : Remote controlled system Automatic display Sequence tables for any set of samples Internal and external standard calculation methods Integrated A/D converters Prints, exports and starts other programs after the completion of a measurement       Applications :

  4. Used to split a mixture of compounds in the fields of analytical chemistry, biochemistry and industrial. Labotronics Ltd. Union House, 111 New Union Street, Coventry CV1 2NT, UK | info@labotronics.com www.labotronics.com