An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High performance liquid chromatography LB-31HPLC info@labotronics.com www.labotronics.com

  2. Overview High performance liquid chromatography is a unit with flow rate range of 0.001̴ 10.000 mL / min, in 0.001 mL. It has a wavelength range of 190 nm to 800 nm. Gradient pump type unit that is equipped with specially designed column oven for GPC. Specifications : Type Gradient pump 0.001̴ 10.000 ml / min, in 0.001 mL increments Flow Rate Range ≤ ± 0.2 % (1.00 ml / min, H2O, R.T., 8.5 MPa) RSD ≤ 0.06 % (1.00 ml / min, H2O, R.T., 8.5 MPa) Flow Accuracy Flow Precision Pump specifications Maximum Pressure Pressure accuracy 63 MPa ≤ ± 3.0 % Pressure pulsation Composition rang ≤0.1 MPa 0 %̴ 100 % Composition precision ≤ 0.2 % RSD

  3. Wavelength range 190 nm̴ 800 nm Wavelength repeatability ≤ 0.1 nm Wavelength accuracy ≤ ± 1.0 nm Band width 6 nm Response time 0.0 sec̴ 5 sec ≤ ± 0.25 × 10-5 AU (empty cell, 254 nm, 1.0 s) Baseline noise Detector specifications ≤0.5× 10-4 A U / h (empty cell, 254 nm, 60 min) 10 mm (analytical cell) Drift Path length Deuterium Lamp and Tungsten Lamp AC 110 V / 220 V ± 10 %, 50 Hz / 60 Hz Light source Power supply Features : Remote controlled system Automatic display Sequence tables for any set of samples Internal and external standard calculation methods Integrated A/D converters Prints, exports and starts other programs after the completion of a measurement

  4. Applications: Used to split a mixture of compounds in the fields of analytical chemistry, biochemistry and industrial. Labotronics Ltd. Union House, 111 New Union Street, Coventry CV1 2NT, UK info@labotronics.com | www.labotronics.com