An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High performance liquid chromatography LB-32HPLC info@labotronics.com www.labotronics.com

  2. Overview High performance liquid chromatography is a unit with flow rate range of 0.001̴10.000 mL / min, in 0.001 mL. It has a wavelength range of 190 nm to 800 nm. Quaternary low pressure pump unit that is equipped with specially designed column oven for GPC. Specifications : Type Quaternary low pressure pump Flow rate range 0.001̴10.000 mL / min, in 0.001 mL increments Flow accuracy ≤ ± 0.2 % (1.00 ml / min, H2O, R.T., 8.5 MPa) RSD ≤ 0.06 % (1.00 ml / min, H2O, R.T., 8.5 MPa) 63 MPa Flow precision Pump specifications Maximum pressure Pressure accuracy ≤ ± 3.0 % ≤ 0.1 MPa Pressure pulsation Composition rang 0̴100 % ≤ 0.3 % RSD Composition precision

  3. Wavelength range Wavelength repeatability 190 nm̴800 nm ≤ 0.1 nm Wavelength accuracy Band width ≤ ± 1.0 nm 6 nm Response time Baseline noise 0.0 sec̴5 sec ≤ ± 0.25 × 10-5 AU (empty cell, 254 nm, 1.0 s) Detector specifications Drift ≤ 0.5 ×10-4 AU / h (empty cell, 254 nm, 60 min) 10 mm (analytical cell) Path length Deuterium Lamp and Tungsten Lamp AC 110 V / 220 V ± 10%, 50 Hz / 60 Hz Light source Power supply Features : Remote controlled system Automatic displays Sequence tables for any set of samples Internal and external standard calculation methods Prints, exports and starts other programs after the completion of a measurement 4 chamber integrated vacuum degasser Integrated A/D converters

  4. Applications : Used to split a mixture of compounds in the fields of analytical chemistry, biochemistry and industrial. Labotronics Ltd. Union House, 111 New Union Street, Coventry CV1 2NT, UK info@labotronics.com | www.labotronics.com