530 likes | 970 Views
ClimateMaster 50Hz Product Overview. Where We Have Been and Where We Are Going…. R-407C. R-407C. W-A. W-A. W-A. R-410A. R-22. R-22. R-22. R-22. W-W. W-W. Current Products. GC H/V Series Models 006 - 60 GR H/V Series Models 006 - 60 GS H/V Series Models 015 - 70 GSW Series
E N D
ClimateMaster 50Hz Product Overview Where We Have Been and Where We Are Going…
R-407C R-407C W-A W-A W-A R-410A R-22 R-22 R-22 R-22 W-W W-W Current Products • GC H/V Series • Models 006 - 60 • GR H/V Series • Models 006 - 60 • GS H/V Series • Models 015 - 70 • GSW Series • Models 036, 060, 120 • TMW Series • Model 100 (kW)
R-407C R-407C W-A Vert Stack R-22 R-22 R-22 R-22 Console Rooftop Current Products • GL H/V Series • Models 072 - 300 • RE Series • Models 03 - 20 • CCE Series • Models 07-19 • 816 Series • Models 10-36
R-407C GR H/V Series • Water-to-Air Packaged Units • Models 006 – 060 (1,5 – 14 kW Cooling Capacity @ WLHP conditions) • Extended range operation • Water Loop or Ground Loop • Spring-mounted compressors • CE Mark • Numerous factory options
R-407C GSW Series • Water-to-Water Units • Models 036, 060, 120 (10, 16, 31 kW Heating Capacity @ WLHP conditions) • Extended range operation • Water Loop or Ground Loop • Spring-mounted compressors • CE Mark • Numerous factory options
R-407C GL H/V Series • Large Capacity Water-to-Air Units • Models 072 – 120 Horizontal (16 – 29 kW Cooling Capacity @ WLHP Cond.) • Models 080 – 300 Vertical (17 – 63 kW Cooling Capacity @ WLHP Cond.) • Extended range operation • Water Loop or Ground Loop • CE Mark • Numerous factory options
R-407C CCE Series • Console Water-to-Air Units • Models 07 – 19 (1,8 – 3,8 kW Cooling Capacity @ WLHP) • Extended range operation • Water Loop or Ground Loop • CE Mark • Numerous factory options
R-410A TMW Series • Large Capacity Water-to-Water Units • Model 100 (100 kW Heating Capacity @ WLHP conditions) • Extended range operation • Water Loop or Ground Loop • Spring-mounted compressors • CE Mark • Numerous factory options
R-407C R-407C R-410A R-410A R-410A R-410A R-22 2007 Product Line • Current GR Series • Current GL Series • Current TMW100 Large Water-to-Water • All New TS Series Water-to-Air Packaged Units • All New TRC Series Console • All New THW Water-to-Water • Current 50Hz R-22 products • Product Catalog / Literature • ClimaSize in S.I. Units
Refrigerant Focus All New Products to be Designed with EarthPure® (R-410A)
EarthPure (R-410A) • 50/50 Blend of R-32 and R-125 • Offers improved efficiency over R-407c • Does not separate from its blended state (near azeotropic) • Non toxic / non flammable • Higher operating pressures • Requires complete product redesign • Lubricant, burst strength, compressor displacement, heat exchanger design
EarthPure (R-410A) • Cannot be Used as a Drop-in for R-22 / R-407c • Environmentally friendly • ZDP (Zero ozone Depletion Potential) • Low Global Warming Potential • Safe • Low toxicity level (same as R-22) • Non-flammable
R-410A Operating Pressures 50 - 70% Higher than R-407c
New Product Line To Be Complete by the End of 2007
R-407C GR H/V Series Currently Available
R-407C GR H/V Series • Water-to-Air Packaged Units • Models 006 – 060 (1,5 – 14 kW Cooling Capacity @ WLHP conditions) • Extended range operation • Water Loop or Ground Loop • Spring-mounted compressors • CE Mark • Numerous factory options
GR H/V Series Efficiencies • WLHP EER (30ºC EWT): 3,1 - 4,0 • WLHP COP (20ºC EWT): 3,9 - 4,7 • GLHP EER (25ºC EWT): 3,6 - 5,3 • GLHP COP (0ºC EWT): 3,0 - 3,7
R-407C GL H/V Series Currently Available
R-407C GL H/V Series • Large Capacity Water-to-Air Units • Models 072 – 120 Horizontal (16 – 29 kW Cooling Capacity @ WLHP Cond.) • Models 080 – 300 Vertical (17 – 63 kW Cooling Capacity @ WLHP Cond.) • Extended range operation • Water Loop or Ground Loop • CE Mark • Numerous factory options
GL H/V Series Efficiencies • WLHP EER (30ºC EWT): 3,5 - 4,1 • WLHP COP (20ºC EWT): 3,9 - 4,9 • GLHP EER (25ºC EWT): 4,3 - 5,8 • GLHP COP (0ºC EWT): 3,4 - 4,3
R-410A TMW Series Large Capacity Water-to-Water Heat Pump • Model TMW100 • 100kW Heating Capacity @ WLHP Conditions • Large capacity / small footprint • Dual Copeland Scroll Compressors Currently Available
R-410A TMW Series Large Capacity Water-to-Water Heat Pump • All service from the front • Control panel • Compressors • TXVs, RVs, filter driers • Dual isolated compressors • Coaxial heat exchangers • Top water connections allow multiple side by side modules for large capacity Front
TMW Series Efficiencies • WLHP EER (30/12ºC EWT): 4,3 • WLHP COP (20/40ºC EWT): 5,0 • GLHP EER (25/12ºC EWT): 5,0 • GLHP COP (0/40ºC EWT): 3,2
R-410A TS Series Product Line
R-410A TS Series Product Line • Models 006 – 070 (1,5 – 16 kW Cooling Capacity @ WLHP Cond.) • Extended range operation • Water Loop or Ground Loop • Spring-mounted compressors • CE Mark • Numerous factory options • Target Date: September
R-410A TS Series Product Line • New black/silver cabinet • Foil backed insulation in air handler for improved indoor air quality and ease of cleaning • Stainless steel drain pan • Scroll/rotary compressors • Horizontal / Vertical Upflow / Vertical Downflow
TS Series Efficiencies* • WLHP EER (30ºC EWT): 4,2 - 4,9 • WLHP COP (20ºC EWT): 5,0 - 5,4 • GLHP EER (25ºC EWT): 4,9 - 5,6 • GLHP COP (0ºC EWT): 3,6 - 3,8 *Estimated based upon lab testing
R-410A TRC Series Console Shown with optional field- installed return air grille
R-410A TRC Series Console • Models 06 – 18 (1,5 – 5 kW Cooling Capacity @ WLHP Cond.) • Ductless application • Removable cabinet • New electronic controls • Extended range operation • Water Loop or Ground Loop • Black subbase • Target Date: September
TRC Series Efficiencies* • WLHP EER (30ºC EWT): 3,8 - 4,0 • WLHP COP (20ºC EWT): 4,5 - 5,1 • GLHP EER (25ºC EWT): 4,4 - 4,6 • GLHP COP (0ºC EWT): 3,3 - 3,7 *Estimated based upon lab testing
R-410A THW Series Water-to-Water • Models 08, 10, 12 kW Heating Capacity (GLHP) • High Temperature (63°C) Output Even at 0°C Loop Temps • All New Cabinet • On-Board Microprocessor Controls • Target Date: October Revealed At Paris Meeting!
R-410A THW Series Features • Compact Size: 650mm wide x 950mm deep x 1225mm tall • Hinged front and top panels for easy service access • Mitsubishi Scroll Compressor • Internal “Smart” Controls • Heating Only Operation • High COP (4,5 - 4,7 @ 0/35°C)
R-410A THW Series Features • Coaxial “Source” Heat Exchanger • Rugged design • Open loop capable • Brazed Plate “Load” Heat Exchanger • Double Isolation Compressor Mounting • Compressor Discharge Muffler • UltraQuiet Sound Package (standard on 50Hz models)
R-410A THW Series Features • Refrigerant Circuit Filter Drier • Insulated Water / Refrigerant Circuits • Internal 2-Way Valve for switching between heating and DHW • Stainless Steel / Black cabinet or Appliance White cabinet • Optional Internal Source/Load Pumps • Optional Internal Expansion Tanks
Internal Controls THW Series Hinged Access Panels Expansion Tanks Muffler 1225 950 Mitsubishi Scroll Compressor Filter Drier 650
THW “Smart” Controls Large (5mm x 5mm) dot matrix display user interface Easy to use menu choices via 5 buttons Blue backlight
R-410A THW “Smart” Controls • Heating and Domestic Hot Water set points • Outdoor Air temperature reset • Warm Weather Shut Down • Cooling System Enable • Flexible Heating Mode • e.g. forced air heating in mild weather • DHW Time Schedule • Preset Heating Temperatures (Adjustable) • Radiant Floor or Radiator Applications
R-410A THW “Smart” Controls • Two-Stage Operation • Backup boiler or second unit • Fault Notification (Red Backlight Screen) • High Pressure • High Compressor Discharge Temperature • Low Pressure • Low Water Temperature • Under/Over Voltage • Bad Thermistor • Emergency DHW Operation
THW Improvements Changes made since Paris prototype unit was built
Increased height to 1225mm to accommodate pumps and provide better access to 2-way valve (Paris unit is 1000mm)
Moved electricalconnections fromthe left side to theback Moved water connections from the top to the back
Coaxial “Source” Heat Exchanger Brazed Plate “Source” Heat Exchanger
Disconnect must be turned off in order to open access panels Full Sheet Metal Compressor Enclosure (next slide)
Extended Range Products • -7 to 49°C EWT • TS series / TMW series / THW series standard with water-refrigerant circuit insulation • It’s likely that new 50Hz products moving forward will be standard as extended range
Future Products… • Conversion of the rest of the product line to EarthPure (R-410A) • GL large capacity water-to-air • Rooftop • GR/GC replacement • For the U.S.: R-22 phase out – January 2010
We Need Your Help… • Input on New Product Development, specifically for the European market • “Wish list” • Competitor Information
Product Development Questions… • Water fittings • Threaded in “inches?” • Loop Flow Center (residential) • Popular in North America • 3-Way Valves allow purging of air • Insulated housing helps with condensation at low water temperatures • Available with 1 or 2 Grundfos pumps • Fittings? (electro-fusion, threaded, barbed)
Grundfos UPS26-99 (1 or 2) Loop Flow Center
Ground Loop (In/Out) 3-Way Valves Purge Pump Connections Heat Pump (In/Out)