Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution

Engineering Technology Division. Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution. Section 4.4 – In-Plant Electrical Distribution. Overview. Loads vary – 5v to 13.8 kV Vital and Non Vital loads Both AC and DC voltage

Rita
Download Presentation

Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Engineering Technology Division Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution

  2. Section 4.4 – In-Plant Electrical Distribution Overview • Loads vary – 5v to 13.8 kV • Vital and Non Vital loads • Both AC and DC voltage • Multiple Power Sources – Battery, Emergency Generators • Protection • Voltage • Current • Faults • Shorts • Connection – Wire and bus trays

  3. Section 4.4 – In-Plant Electrical Distribution Power Plant Distribution - Concept 13.8 kV To 1,460 V To 480 V to 120 V Source 1 Source 2 Transformer Transformer Switchgear Switchgear Transformer Transformer Load Center Load Center Transformer Vital Load Center Source 3

  4. Section 4.4 – In-Plant Electrical Distribution Power Plant Distribution Transformer Switchgear Source Storage Bus Bars Equipment Bus Bars Wires Wires Wires

  5. Section 4.4 – In-Plant Electrical Distribution Power Plant Distribution

  6. Section 4.4 – In-Plant Electrical Distribution Switchgear – Circuit Breakers Installed 13.8 kV Circuit Breaker Removed

  7. Section 4.4 – In-Plant Electrical Distribution Switchgear – Circuit Breakers Front 480 V Circuit Breaker Back

  8. Section 4.4 – In-Plant Electrical Distribution Switchgear – Circuit Distribution Circuit Breaker Fuse

  9. Section 4.4 – In-Plant Electrical Distribution Switchgear Bus Work 4,160 and 13,800 Volts External Internal

  10. Section 4.4 – In-Plant Electrical Distribution Cable Trays 480 / 240 and 120 Volt

  11. Section 4.4 – In-Plant Electrical Distribution Questions?