Solutions Electrical - Cable Sizes & Voltage Drop Electrical Estimating and Drawing Software.Australia's electrical engineering design, estimating, cable calculating and drafting software. Visit: http://www.solutionselectrical.com.au
E N D
Solutions Electrical Short Circuit Currents Fault Level: 12.50 MVA Fault Current: 18.04 kA (rms) Full Load Current: 1443 Amps Short Circuit Currents Fault Level: 20.00 MVA Fault Current: 28.87 kA (rms) Full Load Current: 1443 Amps Short Circuit Currents Fault Level: 20.00 MVA Fault Current: 28.87 kA (rms) Full Load Current: 1443 Amps Short Circuit Currents Fault Level: 12.50 MVA Fault Current: 18.04 kA (rms) Full Load Current: 1443 Amps Gen. Size: 1000 Reactance Xd'': 8. Sec. Voltage: 400 Trans. Size: 1000 kVA Reactance: 5.% Sec. Voltage: 400 Trans. Size: 1000 kVA Reactance: 5.% Sec. Voltage: 400 S.A. Size: 1000 Impedance: 8. Voltage Out: 400 Gen 1 Trans 1 Trans 2 Sol 1 100 Amps Isol Cable Fault level: 3575 Amps 80 Amps Isol Cable Fault level: 3575 Amps Fuse 80 Amps Cable Fault level: 5005 Amps HRC Fuse 50 Amps 25.0 mm2 - Copper Rating: 125 Amps 44mts XLPE 90°C Single Spaced (Trefoil) Voltage: 400 V V.D.: 1.69% I.D.: 1 100 Amps 25.0 mm2 - Copper Rating: 144 Amps 30mts Fire-Rated 110°C Multi-core Spaced (Trefoil) Voltage: 400 V V.D.: 0.92% I.D.: 2 80 Amps 35.0 mm2 - Copper Rating: 91 Amps 22mts XLPE 90°C Multi-core Partial Insulated Voltage: 400 V V.D.: 0.46% I.D.: 3 75 Amps 16.0 mm2 - Copper Rating: 92 Amps 44mts XLPE 90°C Single Spaced (Trefoil) Voltage: 400 V V.D.: 1.27% I.D.: 4 50 Amps 0 Amps Isol 0 Amps Isol 0 Amps Isol 0 Amps Isol Short Circuit Currents Fault Level: 2.40 MVA Fault Current: 3.46 kA (rms) Power Factor: 0.97 X/R Ratio: 0.25 Short Circuit Currents Fault Level: 3.64 MVA Fault Current: 5.26 kA (rms) Power Factor: 0.93 X/R Ratio: 0.4 MB 1-Gen 1 MB 1-Trans 1 MB 1-Trans 2 db 2-Sol 1 20 Amps Isol Cable Fault level: 444 Amps 6 Amps Isol Cable Fault level: 111 Amps 20 Amps Isol Cable Fault level: 143 Amps 80 Amps Isol Cable Fault level: 2288 Amps 100 Amps Isol Cable Fault level: 2288 Amps Fuse 40 Amps Cable Fault level: 1110 Amps 4.0 mm2 - Copper Rating: 31 Amps 22mts PVC 75°C Multi-core Spaced (Trefoil) Voltage: 400 V V.D.: 1.02% I.D.: 6 20 Amps 1.0 mm2 - Copper Rating: 14 Amps 20mts PVC 75°C Single Spaced (Trefoil) Voltage: 400 V V.D.: 0.40% I.D.: 5 2 Amps 1.0 mm2 - Copper Rating: 20 Amps 11mts Fire-Rated 110°C Multi-core Spaced (Trefoil) Voltage: 400 V V.D.: 2.73% I.D.: 7 20 Amps 16.0 mm2 - Copper Rating: 87 Amps 33mts XLPE 90°C Multi-core Spaced (Trefoil) Voltage: 400 V V.D.: 1.64% I.D.: 20 78 Amps 16.0 mm2 - Copper Rating: 107 Amps 22mts Fire-Rated 110°C Multi-core Spaced (Trefoil) Voltage: 400 V V.D.: 1.25% I.D.: 31 89 Amps 10.0 mm2 - Copper Rating: 51 Amps 40mts PVC 75°C Multi-core Touching Voltage: 400 V V.D.: 1.28% I.D.: 50 35 Amps 6 Amps Isol 0 Amps Isol 0 Amps Isol 0 Amps Isol 0 Amps Isol 0 Amps Isol Short Circuit Currents Fault Level: 0.93 MVA Fault Current: 1.35 kA (rms) Power Factor: 0.99 X/R Ratio: 0.11 Short Circuit Currents Fault Level: 2.07 MVA Fault Current: 2.98 kA (rms) Power Factor: 0.99 X/R Ratio: 0.17 Short Circuit Currents Fault Level: 1.01 MVA Fault Current: 1.45 kA (rms) Power Factor: 0.99 X/R Ratio: 0.12 db 2-MB 1-Gen 1 db 8-MB 1-Trans 1 db 17-db 2-Sol 1 16 Amps Isol Cable Fault level: 666 Amps 40 Amps Isol Cable Fault level: 1110 Amps CB 50 Amps Type 'C' CB Cable Fault level: 2775 Amps CB 6 Amps Type 'B' CB Cable Fault level: 111 Amps CB 6 Amps Type 'C' CB Cable Fault level: 111 Amps 6 Amps Isol Cable Fault level: 111 Amps l1 db 3-MB 1-Gen 1 db 12-MB 1-Trans 2 6.0 mm2 - Copper Rating: 46 Amps 15mts PVC 75°C Multi-core Spaced Voltage: 230 V V.D.: 0.57% I.D.: 8 13 Amps 10.0 mm2 - Copper Rating: 59 Amps 40mts PVC 75°C Single Buried Direct Voltage: 400 V V.D.: 1.39% I.D.: 24 38 Amps 25.0 mm2 - Copper Rating: 60 Amps 22mts PVC 75°C Multi-core Partial Insulated Voltage: 400 V V.D.: 0.36% I.D.: 32 45 Amps 1.0 mm2 - Copper Rating: 11 Amps 12mts PVC 75°C Single Partial Insulated Voltage: 230 V V.D.: 0.97% I.D.: 51 4 Amps 1.0 mm2 - Copper Rating: 13 Amps 18mts PVC 75°C Multi-core Spaced (Trefoil) Voltage: 400 V V.D.: 0.73% I.D.: 52 4 Amps 1.0 mm2 - Copper Rating: 15 Amps 21mts PVC 75°C Multi-core Spaced Voltage: 230 V V.D.: 1.70% I.D.: 53 4 Amps 0 Amps Isol 0 Amps Isol 0 Amps Isol 0 Amps Isol 0 Amps Isol 0 Amps Isol Short Circuit Currents Fault Level: 0.70 MVA Fault Current: 1.00 kA (rms) Power Factor: 1.00 X/R Ratio: 0.09 Short Circuit Currents Fault Level: 1.64 MVA Fault Current: 2.36 kA (rms) Power Factor: 0.99 X/R Ratio: 0.15 db4-db 2-MB 1-Gen 1 db 10-db 8-MB 1-Trans 1 CB 6 Amps Type 'B' CB Cable Fault level: 277.5 Amps Fuse 10 Amps Cable Fault level: 357.5 Amps CB 6 Amps Type 'D' CB Cable Fault level: 111 Amps CB 20 Amps Type 'B' CB Cable Fault level: 444 Amps CB 6 Amps Type 'B' CB Cable Fault level: 111 Amps Fuse 6 Amps Cable Fault level: 111 Amps db 14-db 8-MB 1-Trans 1 l18 l19 l20 2.5 mm2 - Copper Rating: 27 Amps 11mts PVC 75°C Multi-core Spaced Voltage: 230 V V.D.: 0.31% I.D.: 12 4 Amps 2.5 mm2 - Copper Rating: 34 Amps 22mts XLPE 90°C Multi-core Buried Direct Voltage: 230 V V.D.: 1.25% I.D.: 10 8 Amps 1.0 mm2 - Copper Rating: 11 Amps 11mts PVC 75°C Multi-core Conduit Voltage: 400 V V.D.: 0.58% I.D.: 40 5 Amps 4.0 mm2 - Copper Rating: 31 Amps 40mts PVC 75°C Multi-core Spaced (Trefoil) Voltage: 400 V V.D.: 1.66% I.D.: 46 18 Amps 1.0 mm2 - Copper Rating: 13 Amps 21mts PVC 75°C Single Touching Voltage: 230 V V.D.: 1.27% I.D.: 47 3 Amps 1.0 mm2 - Copper Rating: 13 Amps 48mts PVC 75°C Multi-core Spaced (Trefoil) Voltage: 400 V V.D.: 1.93% I.D.: 48 4 Amps 0 Amps Isol 0 Amps Isol 0 Amps Isol 0 Amps Sw 0 Amps Isol 0 Amps Isol Short Circuit Currents Fault Level: 0.48 MVA Fault Current: 0.69 kA (rms) Power Factor: 1.00 X/R Ratio: 0.06 db 6-db4-db 2-MB 1-Gen 1 6 Amps Isol Cable Fault level: 666 Amps CB 6 Amps Type 'B' CB Cable Fault level: 143 Amps l2 l5 db 12-db 10-db 8-MB 1-Trans 1 l14 l16 6.0 mm2 - Copper Rating: 50 Amps 22mts PVC 75°C Multi-core Buried Enclosed Voltage: 230 V V.D.: 0.32% I.D.: 15 5 Amps 1.0 mm2 - Copper Rating: 18 Amps 22mts XLPE 90°C Multi-core Spaced Voltage: 230 V V.D.: 1.34% I.D.: 14 3 Amps 0 Amps Isol 0 Amps Isol Short Circuit Currents Fault Level: 0.38 MVA Fault Current: 0.55 kA (rms) Power Factor: 1.00 X/R Ratio: 0.05 db 7-db 6-db4-db 2-MB 1-Gen 1 CB 6 Amps Type 'B' CB Cable Fault level: 277.5 Amps HRC Fuse 6 Amps CB 6 Amps Type 'B' CB Cable Fault level: 166.5 Amps 6 Amps Isol Cable Fault level: 166.5 Amps 6 Amps Isol Cable Fault level: 166.5 Amps l4 2.5 mm2 - Copper Rating: 27 Amps 30mts PVC 75°C Multi-core Spaced Voltage: 230 V V.D.: 0.64% I.D.: 42 3 Amps 1.5 mm2 - Copper Rating: 13 Amps 20mts PVC 75°C Multi-core Partial Insulated Voltage: 230 V V.D.: 1.04% I.D.: 43 4 Amps 1.5 mm2 - Copper Rating: 21 Amps 18mts PVC 75°C Multi-core Buried Direct Voltage: 230 V V.D.: 0.70% I.D.: 44 3 Amps 1.5 mm2 - Copper Rating: 14 Amps 17mts PVC 75°C Single Partial Insulated Voltage: 230 V V.D.: 0.88% I.D.: 45 4 Amps 1.5 mm2 - Copper Rating: 18 Amps 30mts PVC 75°C Multi-core Touching Voltage: 230 V V.D.: 0.78% I.D.: 55 2 Amps 0 Amps Isol 0 Amps Isol 0 Amps Isol 0 Amps Isol 0 Amps Isol l6 l8 l9 l10 jknbhj Client: Contact: PDF created with pdfFactory trial version www.pdffactory.com Company Name: Claymont Pty Ltd Drawn by: Rev. No: 1 Checked by: Date: 8/7/2012