1 / 21

Control and Management Solution for Data-Centers and Computer Rooms

Control and Management Solution for Data-Centers and Computer Rooms. G4. The G4. Perfect “All Built In” solution for control, management and monitoring computer rooms and data-centers.

Sophia
Download Presentation

Control and Management Solution for Data-Centers and Computer Rooms

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Control and Management Solution for Data-Centers and Computer Rooms G4

  2. The G4 • Perfect “All Built In” solution for control, management and monitoring computer rooms and data-centers. • An unique integrated solution that ensures full control of equipments, real time detection of faults and immediate notifications to users. • Works on LAN/WAN network, • Includes GSM modem

  3. Features • Accepts input from up to 5 temperature sensors. • 8 inputs dry contacts. • 4 outputs dry contacts. • RS232 serial connection for power devices (UPS / rectifiers). • Ethernet line interface 10/100 Base auto detect. Network protocols : TCP/IP, UDP/IP, HTTP, SNMP v2, DNS, PPP, SMTP, TELNET,MODBUS client . • Internal cellular modem support GPRS/GSM – Dual or Quad band. • Antenna and SIM card connection.

  4. G4 main screen

  5. Server room Changeyourpointofview Smoke detector SNMP trap Air condition start operation Air Condition stop operation GPRS/SMS Control and Notification Motiondetector Shutdown Servers Wake-up Servers AC Fail AC Recovered Alarm Door / Window open Leak detection and notification High temperature

  6. Control and monitor of IT equipments • Reading and analysis information through SNMP of IT equipments like: servers, switches, printers, … • Features analyzed: CPU load, virtual and physical memory used, used and free space capacity for all SNMP (RFC2790 ) supported equipments. • Check Availability of equipment by ping requests. • Automatic shutdown up to 32 servers in UPS AC failure or a critical event defined by user –for more than 32 need additional Gamatronic’s software called “PSM”. • Wake up servers in the way of “WAKE ON LAN” - (Bios configuration) andwake with delay availability. • SNMP trap to management centers use SNMP manager like: What‘s Up, HP Open View, CA. • SNMP restriction to set/get by community and IP – G4 may use as a server/client SNMP.

  7. IT monitoring screen

  8. IT Monitoring - ConfigurationScreen

  9. Monitoring power systems • G4 performs real time verification of Gamatronic and other UPS’s and power systems manufacturers. • immediate alarm notification such as: AC fail, Low battery, on Battery… . • G4 notifies and operates accordingly: => Shutdown server for prevent damage to IT equipments and data bases, =>send SMS/EMAIL/SNMP trap to relevant users.

  10. POWER+ monitoring screen

  11. POWER+ monitoring screen

  12. Dry contacts • Work with relays that define the status to normally open/close • G4 will detect every changes of these states and immediately notify users . DRY IN: • 8 dry contacts inputs to receive alarms from different sensors such as: Air conditions, doors, smoke detectors, fire detector ,flood and more. • Contacts can be enable/disable in certain hour during the day according to user preferences. DRY OUT: • 4 dry contacts outputs for remote activation of different devices like: Back up air condition, lamp, alarm, gates and more. • Contacts can be activated automatically in one of following cases: 1) status’ change of a certain dry contact IN. 2) High temperature alarm. 3) IT alarm. 4) UPS alarm.

  13. Dry contacts screens

  14. Environment Temperature • G4 can monitor up to 5 temperature measurements sensors (one is provided by default). • All sensors can be configured with high/low limit ,description name and Hysteresis that prevent falsehood notifications when the sensor is in the limit between the normal and critical temperature.

  15. Environment temperature – main screen

  16. Control via SMS • The G4 can send notifications up to 10 mobile phone numbers. These numbers may also have a full control on the unit. • A “status” SMS command reply a short answer of Fail/OK on following parameters: IT monitoring, environment, dry contacts, UPS . • All critical commands will require SMS password and a flag authorization in the WEB interface – near all phone number , • user can mark the number he wants to authorize full control option. • User can choose to receive a status notification from G4 from time to time. Critical commands example: • Shutdown server, wake up server, change dry contact status (open, close, pulse), get the G4’s IP.

  17. The Control via SMS

  18. Additional features • Hardware is not dependent to an external server. • Built- In AJAX based web interface - enables accessibility thru every remote internet browser. • Event group- user can define a group of events he wants and refer them to a particular phone target. • Internal 256 event log available through web server or SNMP. • GPRS communication: where the LAN/WAN network isn’t accessible. • Can operates with the Gamatronic “PSM AC UNIVERSAL” software to increase the shutdown target to more than 32 devices. • Can operates with Gamatronic “GEMSI software” for monitoring several G4 units and other UPS models.

  19. GeMSi Software - Main screen GeMSi main screen, shows real time status of all regions and sites, alarm counter and direct connection to alarmed unit.

  20. GeMSi Software Units in specific site, real time status & name, right click shows all information about the unit.

  21. Thank you

More Related